6
_installation
installation
Safety instructions for the installation
This oven may be installed only by a qualified electrician. The installer is responsible for connecting
the appliance to the mains and observing the relevant safety regulations.
Technical specifications
Input voltage / frequency
Volume (usable capacity)
Output rating
Housing (W x H x D)
Oven interior (W x H x D)
230 V ~ 50 Hz
65 ℓ
max. 2400 W
595 x 595 x 566 mm
440 x 365 x 405 mm
Power connection
A multi-pole isolator switch (with at least 3 mm contact
spacing) must be provided in order to satisfy safety
regulations. The power cable (H05 RR-F or H05 VV-F, min.
1.5 m, 1.5 ~ 2.5 mm²) must be of sufficient length to be
connected to the oven, even if the oven stands on the floor
in front of its built-in cabinet. Open the rear connection cover
of the oven with a screwdriver and loosen the screws of the
cable clamp before you connect the wires to the relevant
connection terminals. The oven is earthed via the ( )-terminal.
(The manufacturer accepts no responsibility for faults or
accidents arising from a defective earth connection)
Please ensure that the power cable is not trapped between the oven and units or wall when
pushing back into position. Do not route cable over any potentially hot surfaces.
installation in the cabinet
This is a built-in oven, which needs to be installed into an upper or lower cabinet.
•
Observe minimum distances.
•
Fix oven on both sides using screws
After installation, remove the vinyl protective film from the door to
the appliance and the protective film from the interior surfaces of the
oven.
BRN/RED BU/BLK
566
595
572
560
595
21
min. 550
min.550
min.600
Lower Cabinet
min. 560
min. 50
min. 600
min. 50
min.560
Air flow
Upper Cabinet
min. 560
min. 50
min. 590
max. 600
Upper Cabinet
min. 550
LAM3401_DG68-00391A-04_EN.indd 6
5/22/2013 11:02:02 AM