The appliance may be connected to the mains supply only by a suitably qualified person.
The mains lead must not be clamped, bent, trapped, or come into contact with hot parts of the appliance.
If the mains lead is damaged, it must be replaced by a qualifi ed person (mains cable must not be
longer than 2m for safety reasons). It should be routed away from the appliance and not trapped between
the appliance and the wall.
Technical data
Outer Dimensions
Width
580mm
Depth
510mm
Height
55mm
Cutout Dimensions
Width
560mm (+2)
Depth
490mm (+2)
Cook Zones
Rear Left
Front Left
Front Right
Rear Right
Ø180-1800/3000W
Ø180-1800/3000W
Ø180-1800/3000W
Ø180-1800/3000W
Total Input Power
Fuse
32A / 16A x 2
7200W
Supply Voltage
1N ~220-240 V/2N ~380-415 V; 50 Hz
Cable Type
22
LAMONA
Appliances
HO5V2V2 1.5mm ², 5 core (Max 2m) or eqv.
For single-phase 220v - 240v UK
connect the wires as
identified below:
• Brown/Black cable = L (Live)
• Blue/Grey cable = N (Neutral)
• Green/yellow cable = (E) (Earth)
For double-phase European Supply
connect the wires as
identified below:
• Brown cable = L1 (Phase 1)
• Black cable = L2 (Phase 2)
• Blue/Grey cable = N (Neutral)
• Green/yellow cable = (E) (Ground)
or
• Black cable = L1 (Phase 1)
• Grey cable = L2 (Phase 2)
• Blue/Brown cable = N (Neutral)
• Green/yellow cable = (E) (Ground)