Electrical connections
IMPORTANT: Ensure that the electricity supply is switched off before connecting. Your hob is
IMPORTANT: The product should only be installed by a suitably qualified person, and in
accordance with all local regulations.
intended for permanent installation.
Your appliance must be connected to fi xed wiring via the use of a double pole switched outlet
with at least 3mm contact separation. The isolation switch must be accessible after installation (see
technical data for fuse rating). We recommend the use of an RCD device as additional protection.
We strongly recommend the appliance is connected by a suitably qualified person.
The product must be installed in accordance with all local regulations.
The terminology DOUBLE POLE -/+ means that both the live and neutral supplies are switched and
disconnected at the same time.
The terminations labelled SUPPLY are connections for the internal house wiring and the terminations
labelled LOAD are for connection to the appliance.
IMPORTANT: The wires in the mains lead are coloured in accordance with the following code:-
Blue........ Neutral
Brown......Live
Green and Yellow.....Earth
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your box, proceed as follows;
Blue
Green & Yellow
(Earth)
Brown
(Live)
(Neutral)
19
User manual LAM1802