Connecting to external ducting (ducted-out mode)
IMPORTANT: To use the cooker hood in ducted-out mode, you must
ensure that the adjuster which is behind the grease filter is set in the
position shown.
IMPORTANT:
The cooker hood can be ducted from the rear or from the top.
The following steps should be taken before fitting the appliance.
If you want to connect the duct hose to
the rear of the cooker hood, then you
should place the cover over the venting
hole on the top of the appliance.
If you want to connect the duct hose to the
top of the cooker hood, then you should
place the cover over the venting hole on
the rear of the appliance. Then fit the
coupling to the venting hole on the top of
the appliance.
In a position that is suitable and will be accessible once the cooker hood is
installed, cut out a circle measuring 130 mm in diameter. This discharge
outlet should be suitable for cooking vapours. It should have a cross
section of at least 150 cm².
Connect a 125 mm ducting hose to the hole that you have just cut out
(please note that the ducting hose is not supplied with the appliance).
Connect the other end of the 125 mm ducting hose to the top or the rear of
the cooker hood.
The maximum distance between the cooker hood and your discharge
outlet should be 3 metres, with one 90 degree bend. For each additional
90 degree bend, the maximum distance is reduced by a metre.