background image

 10

 

 

Enable External Term. 

This command can be used to 

remotely manage the call of a 

mechanical chronothermostat 

installed in the house. 

If this chronothermostat is set to 

a desired temperature (e.g. 22°c), 

you can manage virtual ON-OFF 

via the app, thus allowing you to 

start heating the house as 

desired. 

Use the 

Chronothermostat to 

switch the boiler 

completely on and off. 

ATTENTION

 

If the boiler is switched OFF, 

the internal accumulation 

tank will cool down. 

Enable External Term. 

This command can be used to 

remotely control the general 

ON-OFF of the home heating 

system in combination with 

SET 

Room Temp.  

Room Temp. 

This command can be used to 

remotely manage the room 

temperature read by the remote 

console located in the house. 

If you leave the 

Enable External 

Term.

  set to 

ON

, raising or 

lowering the temperature will 

cause the home heating to start. 

Chronothermostats 

3

 and 

4

 

switch the boiler 

completely on and off. 

ATTENTION

 

If the boiler is switched OFF, 

the internal accumulation 

tank will cool down. 

Chronothermostats 

1

 and 

2

 

can be used to program the 

start of heating in the home 

at a specific time. In fact, 

these two 

chronothermostats activate 

the internal pump and do 

not activate complete shut-

down of the boiler, allowing 

the accumulation tank to 

remain warm for any 

sanitary requirements. 

 

 

APP functions in combination with the 

TERMOBOILER

 boiler

 

 

 

 

 

 

 

 

 

 

 

APP functions in combination with the 

TERMOBOILER

 boiler and the 

REMOTE CONSOLE

 

 

 

 

 

Summary of Contents for IDRO AGUA Navel 2.0 STD

Page 1: ...REMOTE CONTROL 2 0 Navel 2 0 STD Wi Fi System APP INSTALLATION GUIDE ...

Page 2: ...ctor located behind the stove Alternatively if there is no external serial port you can connect it directly to the circuit board via the specific connector Contact an authorised service centre for circuit board connection EXAMPLE of connection via SR232 serial connector located behind the stove EXAMPLE of direct connection to the circuit board Contact an authorised service centre for circuit board...

Page 3: ...3 LAMINOX REMOTE CONTROL 2 0 App Download and install the LAMINOX REMOTE CONTROL 2 0 app on your device ...

Page 4: ...you open the app for the first time click on SIGN UP enter your e mail address and create a password of at least 8 characters On the next page you will have to enter the activation code that will be sent to the e mail address you provided Confirm with the ACTIVATE button Entering an existing Account Click on LOGIN and enter the e mail address and password that you previously registered then confir...

Page 5: ...t the module to your home WiFi in just a few steps 1 2 Press the key Press EXTERNAL MODULE 3 4 Make sure that everything is correctly connected and that the stove is powered Press CONNECTION OK Obtain the serial number of the stove and the MEC code and the REG CODE on the second sheet provided Press CONTINUE ...

Page 6: ...lers TERMOBOILER and Remote Console select this if you have a Termoboiler remote console Enter the MAC code and the REG CODE found on the USER GUIDE sheet Read the NOTE at the end of the page 555555 5F 264F28 123456 IDRO Mountain home Optional Fields Give a name Enter the SERIAL number found on the data label behind the stove NOTE The MAC ADDRESS REG CODE and APP PASSWORD can be found on the USER ...

Page 7: ...09 network go back to the app and press CONNECT AND CONTINUE 5 6 7 8 Select your Wi Fi enter the password then press CONNECT An AP PASSWORD may sometimes be required to access this page see the USER GUIDE Page 6 Connected Check that two ORANGE lights are lit on the module ATTENTION Close all applications Go to your smartphone settings and re connect to our home Wi Fi Open the app again Your stove ...

Page 8: ...8 Control interface Example of an interface for a IDRO stove or boiler The control interface varies depending on the model of stove or boiler ...

Page 9: ...Fi network to which it was connected After resetting the Wi Fi configuration procedure can be repeated again by selecting Wi Fi CONFIGURATION from the drop down menu Deleting the stove entered To delete the stove entered press the menu symbol 3 dots on the bar then press DELETE STOVE in the drop down menu Once the stove has been deleted you can repeat the initial procedure to enter a new stove ...

Page 10: ...s command can be used to remotely manage the room temperature read by the remote console located in the house If you leave the Enable External Term set to ON raising or lowering the temperature will cause the home heating to start Chronothermostats 3 and 4 switch the boiler completely on and off ATTENTION If the boiler is switched OFF the internal accumulation tank will cool down Chronothermostats...

Page 11: ...nected to the WiFi network Flashing The module is connecting to the WiFi network If flashing persists for more than 3 minutes this indicates that you have entered an incorrect password Press the reset button for at least 10 seconds start the WiFi configuration procedure described on page 9 again On The module is connected to the WiFi network 4th Cloud LED orange Off The module is not connected to ...

Page 12: ...Laminox S r l Divisione Idro Zona Industriale Callarella 261 263 62028 SARNANO MC Italy Tel 39 0733 657 622 Fax 39 0733 657 494 www laminox com e mail idro laminox com Manual rev 0 4 ...