9
Step 04.
Add the roof angle and lintel.
First.
Using the
2x CLT panels (angle panels)
135-275 x 28 x 825mm
screw fix them
as per step 2/3 to finish the side walls.
Next.
Screw fix the
1x CLT panels (groove on)
135 x 28 x 1790mm
to the top of the
front wall.
Note.
This is a good time
to ensure your
shed is level and
square.