Lambrecht PROFESSIONAL-IX 3.0 Operating Instructions Manual Download Page 3

(1460x) PROFESSIONAL-IX 3.0    

 

Operating Instructions 

Operating Instructions
Wind Sensors PROFESSIONAL-IX 3.0

1 Introduction

PROFESSIONAL-IX is a very robust, compact and extremely 
reliable wind sensor. The system is specially designed for use 
under extremely low temperatures. 
PROFESSIONAL-IX represents the experience of LAMBRECHT 
in development and production of wind sensors of more than 
150 years.
The system acquires the horizontal air 

fl

 ow and processes 

the measured data into the meteorological parameters wind 
speed or wind direction. 
All measuring parts and the other system components are 
integrated in the sealed, water-proof housing.
The PROFESSIONAL-IX wind sensor is particularly designed 
for use under extreme climate conditions. The 125 watt-
heating of the sensor head allows the operation of the sensor 
within a wide temperature range of -40 to +70 °C.

Setting to work

The wind can be represented by a vector quantity. For a 
complete description of the wind it is necessary to specify 
its speed and direction. The two components are subject to 
spatial and temporal variations, thus, strictly speaking, they 
are valid only for the site where the measuring instrument is 
installed. Therefore, we recommend to select the place of 
installation very carefully.

2.1 Installation 

conditions

2.1.1 Generally

Generally, wind measuring instruments should not measure 
the speci

fi

 c wind conditions of a limited area, but indicate the 

typical wind conditions of a wider terrain. The values measured 
at different places must be comparable. Thus, when installing 
the sensor you should make sure that the place of installation 
is not under the lee of great obstacles. The distance between 
the obstacles and the sensor should be 10 times the height 
of the obstacles (this corresponds to the de

fi

 nition of an un-

disturbed terrain). 
If an 

undisturbed terrain

 of this kind does not exist the sensor 

must be put up at a height of at least 5 m above the obstacle 
height. If the sensor is installed on a roof top the place of instal-
lation must be in the middle of the roof to avoid predominant 
wind directions. If you want to measure both wind direction 
and wind speed, the sensors should be installed at the same 
measuring point and any mutual influence of the sensors 
should be avoided. The sensor pair PROFESSIONAL-IX with 
its arrangement of sensors next to each other easily meets 
this requirement.

The sensor must not be installed onto transmitting 
plants or antennas or close to them. A minimum 
distance of 2 m is to be kept for interference-free 
signal transfer.

2.2 

Tools and installation aids

There are no special tools or materials required for the instal-
lation and maintenance works. All works can be carried out 
with standard tools available in the specialized trade. 

2.3 

Unpacking the sensor

The sensor is packed in a separate box, carefully protected 
against mechanical in

fl

 uences during the transport. 

Please verify that the following parts and documents are 
enclosed:
·  1 sensor PROFESSIONAL-IX 3.0
·  1 operating manual
Accessories: 
(in accordance with the order separately packed)
Connecting cable with plug

2.4 Goods 

inspection

Please verify in detail the delivery with regard to completeness 
and eventual transport damages. In case of eventual claims 
please contact us in writing immediately. 

2.5 Power 

supply

The sensor requires a 24 volt nominal DC power source 
(20…28 V

DC

) for operation. The heater of the PROFESSION-

AL-IX has to be supplied with 24 volt DC and has a power 
consumption of 125 W.

2.6 Installation

Attention! The installation takes place in a dangerous 
height; the assembly personnel must therefore follow 
the safety regulations.

2.6.1  Mast or pipe mounting

Make sure the device is easily accessible so that you 
can set up the north direction for the wind direction 
sensor and perform eventual maintenance works. 
For access to the sensors use a ladder of the appro-
priate length or a telescope working platform of the 
appropriate height, if applicable.

Ladders or other lifting helps must be absolutely 
in order and must be guarantee a secure support! 
Follow the rules for prevention of accidents.

3

Summary of Contents for PROFESSIONAL-IX 3.0

Page 1: ...inciples for mast flange or bore for high flexibility Heating supplied separately from sensor electronic for operation at lowest temperatures Integrated 125 watt heating for optimal heating of the mov...

Page 2: ...icefall rockfall vandalism 2 Impacts or damages caused by over voltages or elec tromagnetic fields which are beyond the standards and specifications in the technical data 3 Damages caused by improper...

Page 3: ...If the sensor is installed on a roof top the place of instal lation must be in the middle of the roof to avoid predominant wind directions If you want to measure both wind direction and wind speed the...

Page 4: ...ss for installation of the sensor between the nuts may be max 10 mm Mounting is to be made in the fol lowing steps 1 Remove the lower thread nut from the sensor 2 The sensor has to be inserted into th...

Page 5: ...rom the mast to the bottom of the casing so that you can later easily dismount the cable Please make sure the cable is protected from humidity on the side of the data processing system resp the power...

Page 6: ...1460x PROFESSIONAL IX 3 0 Operating Instructions Operating Instructions Wind Sensors PROFESSIONAL IX 3 0 5 Dimensional drawings and electrical connections 6...

Page 7: ...1460x PROFESSIONAL IX 3 0 Operating Instructions Operating Instructions Wind Sensors PROFESSIONAL IX 3 0 Electrical connections 7...

Page 8: ...easuring range 0 360 Accuracy 1 Resolution 1 Starting value 0 4 m s Output Id No 00 14601 300 000 0 20 mA 0 360 Id No 00 14601 300 004 4 20 mA 0 360 Id No 00 14601 300 004 0 10 V 360 degr Parameter wi...