(14523/14524) PRO-Modbus 

  

 

     Manual

Manual
Wind Sensors PRO-Modbus (14523/14524)

Accessories: 

(please order separately)

(14565 U17) Traverse  

Id-No. 32.14565.017000 *)

(14567 U10) Traverse  

Id-No. 32.14567.010000

(14565 U19) Lightning rod 

Id-No. 32.14565.019000

Diff erent masts are project-related off ered.

*) Only with 50 mm adapter  Id-No. 32.14567.008000

11. 

Technical data

Measuring principle:  

Hall Sensor Array, non-contact

Range of application:  

temperatures -40...+70 °C heated* · wind speed max. gusts 100 m/s · humidity 0...100 % r.h.

Heating: 

18 W heating • electronically controlled • The heating within the sensor head prevents blocking 
of the moving parts under most climatological conditions.

Supply voltage: 

24 VDC (6...32 VDC)

Current consumption:  

max. 800 mA at 24 VDC and max. heating • 13 mA at 24 VDC and inactive heating 

 

(Note: The heating can be deactivated via software tool. This allows the current consumption 
to be reduced to 8.5 mA at 24 VDC.)

Housing:  

seawater-resistant aluminium · IP 65 in upright position · M12 cable-plug connection · stainless 
steel nut and lock washer

Dimensions:  

see dimensioned drawings

Included in delivery:  

1 sensor (without cable)

Connectable to: 

Lambrecht meteo data loggers · power supply units · user specifi c evaluation systems (not 
included in delivery)

Parameters 

 

Wind direction (14523)  

Wind speed (14524) 

Id-No.

 

 

00.14523.131030

00.14524.101030

Measuring elements: 

 

wind vane •  

3-armed cup • 

 

aluminium · special surface  

aluminium · special surface

Measuring ranges: 

 

0...360° 

0.5...75 m/s 

Accuracy: 

 

± 2° 

± 0,3 m/s 

 10 m/s; ± 0,5 m/s...60 m/s

Resolution: 

 

< 1° 

< 0.1 m/s 

Starting value: 

 

< 0.5 m/s  

< 0.5 m/s

Interface: 

 

RS 485 

RS 485

Protocol: 

 

Modbus RTU 

Modbus RTU

Measuring rate: 

 

4 Hz 

4 Hz

Weight: 

 

0.4 kg 

0.35 kg

Measured values: 

current value · average value · max. value of the average value · min. value of the average value

*) [Remark: In case of icing and formation of ice at the movable sensor measur-
ing element the function is restricted for the period of icing. For installation sites 
with high risk of icing LAMBRECHT provides for specially heated sensors.]

Technical data - Cable

Id-No.: 

32.14567.060010

Structure: 

4-pole · shielded

Flame resistance: 

acc. to UL Style 20549

Length: 

15 m 

Dimensioned drawing - Cable

Subject to change without notice. 

10

LAMBRECHT meteo GmbH 

 

Tel   

+49-(0)551-4958-0

Friedländer Weg 65-67 

 

Fax  

+49-(0)551-4958-312

37085 Göttingen 

 

E-Mail 

[email protected]

Germany 

 

Internet 

www.lambrecht.net

PRO-Modbus_b-de.indd       23.19

Summary of Contents for PRO-Modbus 14523

Page 1: ...easuring range of 60 m s low starting values of 0 5 m s high resolution of measuring values very low needs of maintenance Standards EMC acc to EN 61000 6 2 EN 61000 6 4 EN 61000 4 2 3 4 5 6 11 Namur N...

Page 2: ...an undisturbed terrain of this kind does not exist the sensor must be put up at a height of at least 5 m above the obstacle height If the sensor must be installed on a roof top the place of instal lat...

Page 3: ...orientation select a landmark which is as far as possible up north with regard to the nal position of the wind direction sensor The reference point can be selected using a topographical map 1 25000 T...

Page 4: ...14523 14524 PRO Modbus Manual Manual Wind Sensors PRO Modbus 14523 14524 8 Wiring diagram 4...

Page 5: ...14523 14524 PRO Modbus Manual Manual Wind Sensors PRO Modbus 14523 14524 9 Dimensional drawings Accessory optional Mast adapter Id No 32 14567 008000 5 15 P51 69 P M27x1 5...

Page 6: ...234 is transmitted in the order 0x12 0x34 Example Big Endian 32 bit or 64 bit Register size value 32 bits 0x12345678 is transmitted in the order 0x12 0x34 0x56 0x78 10 2 Device address The addresses 1...

Page 7: ...mal place INT 30202 Wind direction average value since last retrieval 10 1 decimal place INT 30203 Wind direction maximum value 10 1 decimal place INT 30204 Wind direction minimum value 10 1 decimal p...

Page 8: ...tocon guration is started with the data logger met LOG it queries the available mapping registers on each COM interface in the device address range 1 25 For this purpose the number of mapping register...

Page 9: ...Big Endian WORD 31592 Global radiation instantaneous values Low WORD uncompensated 0x04 Big Endian WORD 10 8 1 Mapping register PRO Modbus Register address Register value Unit Factor Description 4600...

Page 10: ...delivery 1 sensor without cable Connectable to Lambrecht meteo data loggers power supply units user speci c evaluation systems not included in delivery Parameters Wind direction 14523 Wind speed 14524...

Reviews: