(14523/14524) PRO-Modbus
Manual
Manual
Wind Sensors PRO-Modbus (14523/14524)
Accessories:
(please order separately)
(14565 U17) Traverse
Id-No. 32.14565.017000 *)
(14567 U10) Traverse
Id-No. 32.14567.010000
(14565 U19) Lightning rod
Id-No. 32.14565.019000
Diff erent masts are project-related off ered.
*) Only with 50 mm adapter Id-No. 32.14567.008000
11.
Technical data
Measuring principle:
Hall Sensor Array, non-contact
Range of application:
temperatures -40...+70 °C heated* · wind speed max. gusts 100 m/s · humidity 0...100 % r.h.
Heating:
18 W heating • electronically controlled • The heating within the sensor head prevents blocking
of the moving parts under most climatological conditions.
Supply voltage:
24 VDC (6...32 VDC)
Current consumption:
max. 800 mA at 24 VDC and max. heating • 13 mA at 24 VDC and inactive heating
(Note: The heating can be deactivated via software tool. This allows the current consumption
to be reduced to 8.5 mA at 24 VDC.)
Housing:
seawater-resistant aluminium · IP 65 in upright position · M12 cable-plug connection · stainless
steel nut and lock washer
Dimensions:
see dimensioned drawings
Included in delivery:
1 sensor (without cable)
Connectable to:
Lambrecht meteo data loggers · power supply units · user specifi c evaluation systems (not
included in delivery)
Parameters
Wind direction (14523)
Wind speed (14524)
Id-No.
00.14523.131030
00.14524.101030
Measuring elements:
wind vane •
3-armed cup •
aluminium · special surface
aluminium · special surface
Measuring ranges:
0...360°
0.5...75 m/s
Accuracy:
± 2°
± 0,3 m/s
10 m/s; ± 0,5 m/s...60 m/s
Resolution:
< 1°
< 0.1 m/s
Starting value:
< 0.5 m/s
< 0.5 m/s
Interface:
RS 485
RS 485
Protocol:
Modbus RTU
Modbus RTU
Measuring rate:
4 Hz
4 Hz
Weight:
0.4 kg
0.35 kg
Measured values:
current value · average value · max. value of the average value · min. value of the average value
*) [Remark: In case of icing and formation of ice at the movable sensor measur-
ing element the function is restricted for the period of icing. For installation sites
with high risk of icing LAMBRECHT provides for specially heated sensors.]
Technical data - Cable
Id-No.:
32.14567.060010
Structure:
4-pole · shielded
Flame resistance:
acc. to UL Style 20549
Length:
15 m
Dimensioned drawing - Cable
Subject to change without notice.
10
LAMBRECHT meteo GmbH
Tel
+49-(0)551-4958-0
Friedländer Weg 65-67
Fax
+49-(0)551-4958-312
37085 Göttingen
Germany
Internet
www.lambrecht.net
PRO-Modbus_b-de.indd 23.19