Wind Sensors METEOROLOGY (145x6)

Subject to change without notice.

No.

00.14576.250 004

00.14576.010 000

Code

(14576 24V)

(14576 I)

   3)

General

Operating temperature range *

-30...+70 °C

0...+70 °C   4)

Power supply

10...30 VDC; 30 mA (int. transducer)

8...15 VDC; 2 mA

Power supply heating

24 VDC; 600 mA; 15 VA

-----

Heating

electronical shaft heating

-----

Technical data

Measuring range; resolution

0...60 m/s; 0.1 m/s

0...60 m/s; 0.1 m/s

Output signals

3...600 Hz (for 0.3...60 m/s)

3...600 Hz (for 0.3...60 m/s) ~ Ron=1 kOhm; 
Roff=10 kOhm

0/4...20 mA (for 0...50 m/s)   1) 2)

-----

Starting value

<= 0.3 m/s 

<= 0,3 m/s

Accuracy

±0.3 m/s <= 10 m/s; ±2% > 10 m/s

±0.3 m/s <= 10 m/s; ±2% > 10 m/s

Distance constant; time constant

5 m; 1 sec

5 m; 1 sec

Dimension

Measuring elements

opto-electronical (incremental)

inductive proximity switch (NAMUR) SJ 3,5 N

Cup rotor

black anodized, sea water resistant 
aluminum

black anodized, sea water resistant aluminum

Housing; paint

aluminum diecasting; RAL9002

aluminum diecasting; RAL9002

Dimensions

H 170 mm; cup rotor Ø 210 mm (R80)

H 170 mm; cup rotor Ø 210 mm (R80)

Weight

approx. 0.4 kg

approx. 0.4 kg

Other

delivered with 12-pin plug and integrated 
transducer

delivered with 12-pin plug

No.

00.14566.200 304

00.14566.000 030

Code

(14566 24V)

(14566 F1000)

   3)

General

Operating temperature range *

-30...+70 °C

0...+70 °C   4)

Power supply

10...30 VDC; 1...30 mA (int. transducer)

12 VDC or constant current 1 mA

Power supply heating

24 VDC; 600 mA; 15 VA

-----

Heating

electronical shaft heating

-----

Technical data

Measuring range; resolution

0...360°; 2.5°

0...358°; 2.5°   5)

Output signals

0/4...20 mA; RLmax = 500 Ohm @15 VDC; 
3x 0...10 VDC; Imax = 10 mA   1)

0...1000 Ohm

Starting value

<= 0.3 m/s

<= 0.3 m/s

Accuracy

±1%

±1%

Damping ratio

0.3

0.3

Dimension

Measuring elements

opto-electronical (144 steps)

linear precision potentiometer

Wind vane

black anodized, sea water resistant 
aluminum

black anodized, sea water resistant aluminum

Housing; paint

aluminum diecasting; RAL9002

aluminum diecasting; RAL9002

Dimensions

H 260 mm; vane L 365 mm

H 260 mm; vane L 365 mm

Weight

approx. 0.6 kg

approx. 0.6 kg

Other

delivered with 12-pin plug and integrated 
transducer

delivered with 12-pin plug; the potentiometer 
has 3 connections (start, slider, end); 4-wire 
circuit; slider load max. 5 mW

*) Remark: In case of possible icing and 
formation of ice at the movable sensor 
measuring element the function is restricted 
for the duration of icing.

1)   each max. load 500 Ohm at 15 VDC

3)   intrinsically safe transducer

2)   overscaling up to 60 m/s possible
(0...24 mA = 0...60 m/s)
(4...23.2 m/s = 0...60 m/s)

4)   -30...+70 °C by non-icing conditions

5)   2° blank winding to north

Summary of Contents for METEOROLOGY 14576-24 V

Page 1: ...with extremely low friction to detect rotations this also guarantees a long service life Cup Anemometer The three armed cup anemometer with a diameter of 215 mm is rotated by the wind The number of re...

Page 2: ...ny mutual influence of the sensors A wind sensor pair easily meets this requirement since the sensors are set up side by side Their horizontal distance should be approximately 1 5 m The two sensors mu...

Page 3: ...nt dependent switching or monitoring points 2 a Switching point The amplifier switching point must be within a proximity switch current consumption range of 1 2 mA to 2 1 mA 2 b Cable damage monitorin...

Page 4: ...the wind vane this way you can locate the reference point by aiming at it over the axis Now you must turn the sensor casing on the mounting tube until the tip of the wind vane points to the reference...

Page 5: ...ignement Id No 32 14565 060 xxx Coupler socket Id No 65 53070 470 100 View of the socket from the solder side View of the socket from the plug side View of a cable end The single leads of the cabel ar...

Page 6: ...6 145x6 METEOROLOGY Operating Instructions Operating Instructions Wind Sensors METEOROLOGY 145x6 14576 I Id No 00 14576 010 000 14576 24V Id No 00 14576 250 004 Dimensions...

Page 7: ...14566 24V Id No 00 14566 200 30 Wind tunnel results DWD Hamburg Wind speed sensor 14576 24V Instantaneous value v Measured frequence f m s Hz 0 30 0 1 07 7 5 2 10 16 5 4 95 45 9 82 93 14 75 142 19 80...

Page 8: ...cup rotor 210 mm R80 Weight approx 0 4 kg approx 0 4 kg Other delivered with 12 pin plug and integrated transducer delivered with 12 pin plug No 00 14566 200 304 00 14566 000 030 Code 14566 24V 14566...

Reviews: