aem.eco
LAMBRECHT meteo
|
AEM
|
INDUSTRY
page
–
4
If there is no
undisturbed terrain
, the sensor must be set up at a height that exceeds the height of the obstacle by at
least 5 m.
If the sensor must be installed on a roof top the place of installation must be in the middle of the roof to avoid
predominant wind directions.
If you want to measure both wind direction and wind speed, install the sensors at the same measuring point,
if possible, and make sure to avoid any mutual influence of the sensors. A wind sensor pair easily meets this
requirement since the sensors are set up side by side. Their horizontal distance should be approximately 1.5 m. The
two sensors must be staggered vertically so that the lower edge of the upper wind speed sensor is 0.1 to 0.5 m above
the upper edge of the lower wind direction sensor.
Principles of installation
Attention! Because the installation takes place in a dangerous height, the assembly personal must follow
the rules for prevention of accidents.
I. TRAVERSE WITH BORE (ID-NO. 32.14567.010 000)
At the traverse at each end are bores with a slot and with a Ø 30 mm.
1. Remove the lower nut from the sensor.
2. Put a sensor with assembled cable sidewise into the bore.
3.
Attach the sensor with the flat side of detached nut from the lower side. Tighten with a suitable tool (wrench
size 36), until a twisting safety of the sensor aligned to the north is given.
II. MOUNTING STRAP OR BORE
The material thickness for mounting the sensor between the nuts must not exceed 10 mm.
1.
Remove the lower thread nut from the sensor. At sensor type with assembled cable to take off the nut over
completely cable length.
2. The sensor with cable-plug connection is led without cable into the bore and fastened by the opposite side with
the loose nut as under I.3.
3.
The loose nut to be touched now with the flat side first over the cable, in order to fasten the sensor as under I.3.
III. MAST OR PIPE MOUNTING
Make sure the device is easily accessible so that you can set up the north direction for the wind direction
sensor and perform any maintenance work. To reach the sensors use a ladder of the appropriate length or a
telescoping working platform of the appropriate height.
Ladders or other lifting helps must be absolutely in order and must be guarantee a secure support! Follow
the rules for prevention of accidents.
Mount the sensors at the top of grounded tube with an outer diameter Ø 48-50 mm. The mast adapter (see
accessories) is obligatory.
Summary of Contents for aem INDUSTRY
Page 1: ...USER MANUAL Wind Sensors INDUSTRY...
Page 7: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 7 Wiring diagram...
Page 8: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 8 Dimensioned drawing wind speed sensor...
Page 9: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 9 Dimensioned drawing wind direction sensor 3 10 mm...