background image

aem.eco

LAMBRECHT meteo    

|

    AEM

    |

 

   INDUSTRY

page 

 

4

If there is no 

undisturbed terrain

, the sensor must be set up at a height that exceeds the height of the obstacle by at 

least 5 m.

If the sensor must be installed on a roof top the place of installation must be in the middle of the roof to avoid 
predominant wind directions. 

If you want to measure both wind direction and wind speed, install the sensors at the same measuring point, 

if possible, and make sure to avoid any mutual influence of the sensors. A wind sensor pair easily meets this 

requirement since the sensors are set up side by side. Their horizontal distance should be approximately 1.5 m. The 
two sensors must be staggered vertically so that the lower edge of the upper wind speed sensor is 0.1 to 0.5 m above 
the upper edge of the lower wind direction sensor.

Principles of installation

Attention! Because the installation takes place in a dangerous height, the assembly personal must follow 
the rules for prevention of accidents.

I. TRAVERSE WITH BORE (ID-NO. 32.14567.010 000)

At the traverse at each end are bores with a slot and with a Ø 30 mm.

1.  Remove the lower nut from the sensor. 

2.  Put a sensor with assembled cable sidewise into the bore.

3. 

Attach the sensor with the flat side of detached nut from the lower side. Tighten with a suitable tool (wrench 

size 36), until a twisting safety of the sensor aligned to the north is given.

II. MOUNTING STRAP OR BORE

The material thickness for mounting the sensor between the nuts must not exceed 10 mm.

1. 

Remove the lower thread nut from the sensor. At sensor type with assembled cable to take off the nut over 

completely cable length. 

2.  The sensor with cable-plug connection is led without cable into the bore and fastened by the opposite side with 

the loose nut as under I.3. 

3. 

The loose nut to be touched now with the flat side first over the cable, in order to fasten the sensor as under I.3.

III. MAST OR PIPE MOUNTING

Make sure the device is easily accessible so that you can set up the north direction for the wind direction 
sensor and perform any maintenance work. To reach the sensors use a ladder of the appropriate length or a 
telescoping working platform of the appropriate height.

Ladders or other lifting helps must be absolutely in order and must be guarantee a secure support! Follow 
the rules for prevention of accidents.

Mount the sensors at the top of grounded tube with an outer diameter Ø 48-50 mm. The mast adapter (see 

accessories) is obligatory.

Summary of Contents for aem INDUSTRY

Page 1: ...USER MANUAL Wind Sensors INDUSTRY...

Page 2: ...ion 3 Selectingtheplaceofinstallation 3 Principlesofinstallation 4 Settingupthenorthdirectionforthewindvane 5 Electricalconnections 6 Heating 6 Maintenance 6 Wiringdiagram 7 Dimensioneddrawingwind spe...

Page 3: ...dthermally decoupledsensorhead Lowfriction hardlyanywearandthereforeimprovedreliabilityanddurabilityduetodoubleballbearingsofthe measuringelementsontherotaryaxes Maximumload bearingcapacityduetothedim...

Page 4: ...ove thelowernutfromthesensor 2 Putasensorwithassembledcablesidewiseintothebore 3 Attach thesensorwiththeflatsideofdetachednutfromthelowerside Tightenwithasuitabletool wrench size 36 untilatwistingsafe...

Page 5: ...nlythenupward inordertoaccordinglyalignthesensorswithtraverseunderassistanceofapartneron ground Setting up the north direction for the wind vane For winddirectionmeasurements thenorthmarkonthesensormu...

Page 6: ...nEMCfairPg socket Alternativelytheleadcanbelaid alsocompletelyinthepipesofamast ifthemastisaccordinglyprepared To reduce the risk of inductive interference the sensor must be properly grounded screeni...

Page 7: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 7 Wiring diagram...

Page 8: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 8 Dimensioned drawing wind speed sensor...

Page 9: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 9 Dimensioned drawing wind direction sensor 3 10 mm...

Page 10: ...aem eco LAMBRECHT meteo AEM INDUSTRY page 10 Mast adapter Id No 32 14567 006 000 ACCESSORIES OPTIONAL Traverse Id No 32 14567 010 000...

Page 11: ...dingtotheEuropeanDirectives2002 96 ECand2003 108 EC WasteElectricaland ElectronicEquipment Donotdisposetheolddeviceinthehouseholdwaste Foranenvironmentallyfriendlyrecyclinganddisposalofyourolddevice c...

Page 12: ...r resistantAluminium anodized IP55 shaft 32mmwithblackringofplasticsforthermalisolation whenheated for mounting bore 30mmatmaximal10mmmaterialthickness Dimensions seedimensioned drawings Scope of deli...

Reviews: