3.4  Electrical connection 

The cable is connected to the sensor by means of a splash-proof plug connection in the shaft of the sensor. Before 

mounting the sensor on the fitting tube, the cable with the plug connector has to be passed through the tube. The 
electrical connection of the different models can be found in the wiring diagram. 

If the sensor is connected incorrectly, the sensor or connected components may be damaged.

Summary of Contents for aem 24513

Page 1: ...USER MANUAL Maritime Wind Sensor 24513...

Page 2: ...n 6 3 1 Unpacking 6 3 2 Choice oftheinstallationsite 6 3 3 Mounting 6 3 4 Electricalconnection 7 3 5 Cableentries 8 3 6 Start up 8 3 7 Functionaltest 8 4 Serviceandmaintenance 8 4 1 Replacementofspare...

Page 3: ...ionconditions 2 Description 2 1 General Thewindsensor24513 NMEAisspecificallydesignedfortheoperatingonships oilrigs andotherapplicationson sea Thehousingand themeasuringelements aremadeofaseawaterresi...

Page 4: ...aem eco LAMBRECHT meteo AEM u sonic WS6 page 4 2 3 Dimensioned drawing...

Page 5: ...thatthesensorcannotgenerateameasuringvaluebecausee g asensorelementisdefectorimplausible raw valuesare collected thesensoroutputs inthecorrespondingdataprotocoltheabovementionederrorcode e g 999 9 an...

Page 6: ...or 24513 NMEA thenthefittingtubeisapartofthetraverse Before thescrewsofthesensoraretightened thesensormustbe adjustedto north Inordertoinstall thewind sensorfastandcorrectregardingthe north adjustment...

Page 7: ...means ofasplash proofplugconnectionintheshaftofthesensor Before mountingthesensoronthefittingtube thecablewiththeplugconnectorhastobepassedthroughthetube The electricalconnectionofthedifferentmodels c...

Page 8: ...asimpleperformancecheckasmentionedherecanbecarriedout To checkthesensorforwind directionthewindvaneissetinthedirectionsNORTH EAST SOUTH WESTand fixedin thesepositions forawhile Accordinglytothisdirec...

Page 9: ...shippingaddress ofour companyismentionedinthisoperatinginstructions 4 3 Ordering spare parts Incase thatthementioned sparesarerequiredforreplacementortobeputonstock pleasepassusthefollowing informatio...

Page 10: ...pe Cap 1 33 14676 015000 15 Sicherungsblech Locking plate 1 33 14676 017000 16 Strebe schwarz RAL 9005 Brace black 2 33 14511 160030 17 Gewicht schwarz RAL 9005 Weight black 1 33 14511 051010 19 Zyl S...

Page 11: ...windvaneof90 Wind speed Measuringelement Three armedcuprotor Measuring range 0 4 60m s Accuracy 2 FS Resolution 0 1m s Startingvalue 0 4 m s General specifications Rangeofapplication Temperature 35 70...

Reviews: