background image

4

LAMBRECHT meteo GmbH 

 Tel 

+49-(0)551-4958-0

Friedländer Weg 65-67 

 Fax 

+49-(0)551-4958-312

37085 Göttingen 

  

E-Mail 

[email protected]

Germany 

  

Internet 

www.lambrecht.net

8141_62-b.de.indd          11.20

P

DB

DB

P

P

P

 

P

14...21

(8141.62) Sensor Shelter

Operating Instructions

Operating Instructions
Sensor Shelter (8141.62)

Subject to change without notice.

 

 

(8141.62) Sensor Shelter 

Id-No. 00.08141.620000

Range of application:  

 

-50...+80 °C

Amount of lamellas:   

 

11 (3 lamellas closed, 7 lamellas normal, 1 lamella with 73 mm diameter opening)

Dimensions: 

 

 

diameter = 120 mm, height = approx. 297 mm (incl. holder)

for mast diameter:   

 

40...60 mm

Screwing for sensor Ø:    

14...21 mm

Weight: 

 

 

< 535 g without holder (weight of the holder: < 545 g)

Material:  

 

 

lamellas made of UV resistant plastic material, UL 

fl

 ammability rating HB

 

 

 

holder made of V4A stainless steel, white powder-coated RAL 9003

Further accessories:   

 

Screwing for sensor Ø 10...15 mm · screwing for sensor Ø 18...25 mm · 

(please order separately)

   

 

adapter for sensor diameter 5 mm 

Please note the loss that unauthorised 
manipulation of the system shall 
result in the loss of warranty and 
non-liability. Changes to system 
components require express written 
permission from LAMBRECHT meteo 
GmbH. These activities must be 
performed by a quali

fi

 ed technician.

The warranty does not cover:

1.  Mechanical damage caused by 

external impacts (e.g. icefall, 
rockfall, vandalism).

2.  Impacts or damage caused by over-

voltage or electromagnetic fields 
which are beyond the standards and 
speci

fi

 cations of the device. 

3.  Damage caused by improper 

handling, e. g. by using the wrong 
tools, incorrect installation, incorrect 
electrical installation (incorrect 
polarity) etc.

4.  Damage caused by using the device 

outside the specified operation 
conditions.