background image

8

Operating Instructions
Precipitation Sensors (15188)+(15188 H)

(15188) Precipitation Sensors

Operating Instructions

Quality System certified by DQS according to
DIN EN ISO 9001:2000 Reg. No. 003748 QM

15188-ST1_b-de.pmd

44.08

Subject to change without notice.

Wilh. LAMBRECHT GmbH
Friedländer Weg 65-67
37085 Göttingen
Germany

Tel

+49-(0)551-4958-0

Fax

+49-(0)551-4958-312

E-Mail

[email protected]

Internet

www.lambrecht.net

General Accessories

32.15188.060 090

(15188 U60i) Connecting cable (2-core)
sensor/ data logger, L=7 m

00.15180.400 000

(1518 S4) Stainless steel mast for
concrete foundation

00.15180.800 000

(1518 S8) Stainless steel mast for
concrete foundation with base plate

32.15180.021 010

(1518 U21a) Bird protection ring

33.15180.049 000

(1518-49) Dirt pan (spare part)

For varieties with heating (H-varieties)

32.15188.060 090

(15188 U60i) Connecting cable (2-core)
sensor/ data logger, L=7 m

00.15123.242 000

(15123) Filament transformer

32.15188.060 060

(15188 U60f) Connecting cable (2-core)
sensor/ filament transformer, L=

1

 m

00.15180.400 100

(1518 S4a) Stainless steel mast for
concrete foundation with support for the
filament transformer

00.15180.800 030

(1518 S8c) Stainless steel mast for
concrete foundation with base plate and
support for filament transformer

Technical data

(15188) Variety with 2 cm

bucket, unheated

Id-No.

00.15188.002 000

Measuring principle Weighing tipping bucket designed

acc. to Joss-Tognini

Measuring range

2 cm³ (2g water) - volume of bucket
0...10 mm/ min

Resolution

0.1 mm

Accuracy

± 2% with intensity correction

Range of application 0...+70°C - measuring
Pulse output

Reed contact · polarity protected ·
bounce-free signal

Current consump.

Max. 100 

μ

A · typical 50 

μ

A

Supply voltage

4...30 V

DC

Load

Max. 30 V

DC

/ 0.5 A

Dimensions

See dimensional drawing

Suitable for mounting Ø 60 mm
Weight

Approx. 4 kg

Standards

WMO-No. 8 • VDI 3786 Bl. 7
EN 50081/82 • VDE 0100

(15188 W4) Variety with 4 cm

bucket, unheated

Data like (15188), but for very high precipitation intensity

Id-No.

00.15188.004 000

Measuring range

4 cm³ (4g water) - volume of bucket
0...20 mm/ min

Resolution

0.2 mm

(15188 H) Variety with 2 cm

3

 bucket, heated

Data like (15188) 00.15188.002 000, but in additional with con-
trolled 2-circuit-heating:

Id-No.

00.15188.202 000

Heating data

Electronic controlled, dual-circuit

Accuracy

4°C ± 2°C, controlled temperature
within a range of -20...+4°C

Heating power

100 VA (funnel)
70 VA (outlet/ tipping bucket)

Supply voltage

42 V

AC

Range of application -30...+70°C (no icing, no snowdrift)

(15188 H W4) Variety with 4 cm

3

 bucket, heated

Date like (15188 W4) 00.15188.004 000, but in additional with
controlled 2-circuit-heating, like (15188 H)

Id-No.

00.15188.204 000

Safety instructions

This system is designed according to the state-of-the-art accept-
ed safety regulations. However, please note the following rules:
1. Before setting into operation, please read all appropriate

manuals!

2. Please take notice of internal and state-specific guidelines

and/or rules for the prevention of accidents (e.g. the profes-
sional association). If necessary ask your responsible safety
representative.

3. Use the system according to the manual’s regulations only.

4. Always leave the manual at hand at the place of work of the

system.

5. Use the system in technically correct conditions only! You

have to eliminate influences immediately, which impair the
security .

6. Please note the loss of warranty and non-liability by unau-

thorized manipulation of the system. You need a written
permission of the Wilh. LAMBRECHT GmbH for changes of
system components. These activities must be operated by
a qualified technician.

7. Prevent the ingress of liquids into the devices without per-

mission.

Summary of Contents for 15188

Page 1: ...oof 2 cm tipping bucket 2 g water for precise precipitation mea suring in regions with normal rain falls 4 cm tipping bucket 4 g water for precise precipitation mea suring in regions with heavy rain f...

Page 2: ...g bucket The tipping bucket can hold 2 cm 2 g resp 4 cm 4 g of water The collecting surface of 200 cm WMO standard means that one bucket charge is equivalent to a precipitation rate of 0 1 mm resp 0 2...

Page 3: ...hen fitting the tipping bucket proceed with utmost caution so that the sharp edges of the tipping bucket are not damaged and the middle wall is not bent During operation the tipping bucket lies on the...

Page 4: ...rical connections The sensor will be connected to the cable by leading the cable through the conduit gland to the connector inside the sensor housing Recommended cable type 2 4 x AWG 2O CU L sw diamet...

Page 5: ...cm buckets test container of water must be conducted into the collecting funnel through a nozzle in such a way that the drops fall into the funnel beside the outlet The nozzle of the test container a...

Page 6: ...ing Instructions Precipitation Sensors 15188 15188 H 15188 Precipitation Sensors Operating Instructions fig 7 with heating without heating Connecting diagrams for use of the bounce free signal output...

Page 7: ...7 Operating Instructions Precipitation Sensors 15188 15188 H 15188 Precipitation Sensors Operating Instructions fig 8 with heating without heating Connecting diagrams to data logger TROPOS...

Page 8: ...0 5 A Dimensions See dimensional drawing Suitable for mounting 60 mm Weight Approx 4 kg Standards WMO No 8 VDI 3786 Bl 7 EN 50081 82 VDE 0100 15188 W4 Variety with 4 cm3 bucket unheated Data like 1518...

Reviews: