INSTALLATION

- 22 

-

INSTALLATION INSTrUCTIONS

CAUTION!

 

The installation and maintenance of pyrolitic boilers is done only by a specialized firm authorized to carry out such activities. 

 

The installation of the boilers requires the preparation of a preliminary project that complies with the active norms and 

prescriptions. 

 

The joining of the boiler with the heating installation is done only by a qualified technician. 

 

When installing the boiler, one should raise its lower part by 10 mm.

-  The boiler’s construction allows its connection to a heating installation with a maximal work pressure of 200 kPa (2 bar) 

and a maximal temperature of the outgoing water of 95 degrees Celsius, with forced or gravitational circulation.

-  The installation must be done in a special room over a non-flammable material with a minimal height of 50 mm, and a 

constant access of air for burning must be present via an opening with a minimal area of 0,4 m2 (20cm x 20cm).

-  The connection between the boiler and the chimney must also be made of non-flammable material, mechanically robust, 

reliably tight, with a diameter no less than the diameter of the chimney. 

-  Its length should be no more than one meter and it should have an upward slope from the boiler to the chimney.

-  The joining dimensions of the exit and entrance to the heat installation can be seen on sketch 1.

-  The cricket under the entrance for the incoming water can be used for the installation of a tap or it can be blocked. 

-  The tap serves for filling in or emptying the water from the boiler and the installation. 

-  During the process of filling, the pressure of the water must not exceed 350 kPa.

-  It is recommended to connect the boiler to a system with a 4-way mixing valve, the purpose of which will be to maintain 

the temperature of the water in the boiler around 70 degrees Celsius.

-  If the client wishes, a pellet burner can be attached to the boilers with heat capacity of 25 and 32 kW. 

If this is the case, here is what must be done:

1) Remove the existing lower door.

2) Install the door with an entrance to the pellet burner and regulation of the door’s hinges.

3) Install the pellet burner at the lower door.

-  The burner is placed at the door entrance with the corresponding tightness. 

  It is attached with nuts, under one of which a 

SPECIAL “L”- SHAPED METAL PART

 is attached, which presses against 

the final switch, thus giving information that 

THE BURNER IS INSTALLED

  It is absolutely forbidden to eliminate this protection, as it is directly connected with fire safety measures.

-  When installing the burner, it must be heeded that the system is in proper position (leveled). 

  The hose must be stretched and the braces tight.

-  After the burner is mounted to the boiler, it must be plugged in the electric mains, according to the supplied diagram. 

  Special attention must be paid to the protective grounding of the installation.

-  The fuel transporter is connected to the burner by a special plug and contact, and is controlled by a specific algorithm 

(the burner has two contacts, CAUTION!)

THE  LOWER  CONTACT  IS  ALWAYS  UNDER  VOLTAGE  AND  SERVES  FOR  PRIMARY  LOADING  OF  THE  FUEL 

TRANSPORTER, 

and the other is for normal operation.

240

240

155

33

ø152

G1/2”

640

1020/1100/1300

560/640/840

11

36

296

186

1040

1350

10

0

680

255

10

G6/4

G6/4

G3/4

Summary of Contents for PYROTHERM 30

Page 1: ...0 LIBRETTO DI INSTALLAZIONE E MANUTENZIONE INSTALLATION AND MAINTENANCE MANUAL NOTICE D INSTALLATION ET D ENTRETIEN caldaia a legna PELLET ECOLOGICAL WATER HEATING BOILERS chaudi res cologiques eau PY...

Page 2: ...ty installation use and maintenance of the boiler Keep the manual in a safe place for future consultation Installation must be carried out by qualified personnel in conformance with technical standard...

Page 3: ...ork of Agents and Dealers who are backed up by LAMBORGHINI SERVICE which ensures qualified equipment assistance and maintenance GUARANTEE PYROTHERM boilers have a SPECIFIC GUARANTEE which begins from...

Page 4: ...NSTALLATION INSTRUCTIONS FOR INSTALLATION Page 20 ELECTRICAL DIAGRAM OF THE CONTROL PANEL 21 CONNECTING DIAGRAMS 22 PROTECTION OF THE BOILER FROM OVERHEATING 23 USE AND MAINTENANCE INSTRUCTIONS FOR EX...

Page 5: ...iler 70 90 110 l Maximal permissible work pressure 200 200 200 kPa Maximal permissible work temperature 90 90 90 C Min temperature of the flow back boiler water 65 65 65 C Joining pipes to the serpent...

Page 6: ...le for the igni tion valve The control panel contains a luminous net switch that turns the boiler on a boiler thermostat which regulates the tempe rature at the exit of the boiler thermo and manometer...

Page 7: ...and the installation During the process of filling the pressure of the water must not exceed 350 kPa It is recommended to connect the boiler to a system with a 4 way mixing valve the purpose of which...

Page 8: ...2 1X 2 1X 3 1X 4 FU1 safety device S1 luminous net switch POWER S2 switch for mode selection Pellet burner SA1 boiler thermostat Thermostat B SA2 failure thermostat SA3 thermostat for exhaust gases H...

Page 9: ...ecting the boiler with an accumulating vessel 1 3 2 M Recommended connection of the boiler with a 4 way valve 3 2 1 4 5 6 7 1 boiler 2 4 way mixing valve 3 temperature sensor 4 circulation pump 5 heat...

Page 10: ...valve block and accu mulating vessel M Protection of the boiler from overheating Boiler with a coolant and a safety valve regulated by temperature Honeywell TS 130 3 4 A temperature of opening the val...

Page 11: ...f the steel heat transfer unit When filling up with water one must be cautious not to allow any air penetration in the system The water is only used for the specified purpose It is inadmissible to pum...

Page 12: ...ced in a longitudinal manner over the chamber nozzle and in a way such that none of the splinters get stuck in it 2 Special attention must be paid not to block the closing of the ignition valve 3 When...

Page 13: ...dary one With proper burning the ceramic surface of the burning chamber has to be white or light gray and dry and the quantity of the formed ash small Boiler s mode of operation with pellet burner the...

Page 14: ...the bottom where it will burn from the high temperature Burning chamber The ash in the burning chamber that lies on the bottom over the ceramic fireplace must be cleaned with the rake always when the...

Page 15: ...pportare senza obbligo di preavviso tutte le modifiche che ritiene pi opportuno per l evoluzione del prodotto The illustrations and data given are indicative and are not binding on the manufacturer LA...

Reviews: