TAURA D MCS

13

EN

cod. 3541A222  -  Rev. 05 - 04/2013

ECO/COMFORT selection

The unit has a function that ensures a high domestic hot water delivery speed and max-
imum comfort for the user. When the device is activated (COMFORT mode), the water
contained in the boiler is kept hot, thereby ensuring immediate availability of hot water
on opening the tap, without waiting times.
The user can deactivate the device (ECO mode) by pressing the 

eco/comfort

 button

(detail 7 - fig. 1). In ECO mode the display activates the ECO symbol (detail 12 - fig. 1).
To activate the COMFORT mode, press the 

eco/comfort

 button (detail 7 - fig. 1) again.

Sliding Temperature

When the optional external probe is installed, the boiler adjustment system works with
"Sliding Temperature”. In this mode, the temperature of the heating system is controlled
according to the outside weather conditions, to ensure high comfort and energy saving
throughout the year. In particular, the system delivery temperature is decreased as the
outside temperature increases, according to a specific "compensation curve”.
With Sliding Temperature adjustment, the temperature set with the heating buttons (de-
tail 3 - fig. 1) becomes the maximum system delivery temperature. It is advisable to set
a maximum value to allow system adjustment throughout its useful operating range.
The boiler must be adjusted at the time of installation by qualified personnel. Possible
adjustments can in any case be made by the user to improve comfort.
Compensation curve and curve offset
Press the 

reset

 button (detail 6 - fig. 1) for 5 seconds to access the "Sliding temperature"

menu; the display shows "CU" flashing.
Use the DHW buttons (detail 1 - fig. 1) to adjust the curve from 1 to 10 according to the
characteristic. By setting the curve to 0, sliding temperature adjustment is disabled.
Press the heating buttons (detail 3 - fig. 1) to access parallel curve offset; the display
shows "OF" flashing. Use the DHW buttons (detail 1 - fig. 1) to adjust the parallel curve
offset according to the characteristic (fig. 6).
Press the 

reset

 button (detail 6 - fig. 1) again for 5 seconds to exit the "Sliding Temper-

ature" menu.
If the room temperature is lower than the required value, it is advisable to set a higher
order curve and vice versa. Proceed by increasing or decreasing in steps of one and
check the result in the room.

fig. 6 - Example of compensation parallel curve offset

Adjustments from Remote Timer Control

A

If the Remote Timer Control (optional) is connected to the boiler, the above ad-
justments are managed according to that given in table 1.

Table. 1

System water pressure adjustment

The filling pressure with system cold, read on the boiler water gauge (detail 2 - fig. 7),
must be approx. 1.0 bar. If the system pressure falls to values below minimum, the boiler
stops and fault  F37

 is

displayed. Bring it to the initial value by means of the filling cock

(detail 1 - fig. 7) (

A

 = Open - 

B

 = Closed). At the end of the operation always close the

filling cock.

fig. 7 - Filling cock

3. INSTALLATION
3.1 General Instructions

BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSON-
NEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL
MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRESCRIPTIONS OF NA-
TIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP.

3.2 Place of installation

The combustion circuit is sealed with respect to the place of installation, therefore the
unit can be installed in any room. However, the place of installation must be sufficiently
ventilated to prevent the creation of dangerous conditions in case of even small gas
leaks. This safety standard is required by the EEC Directive no. 2009/142 for all gas
units, including those with sealed chamber
The unit is suitable for operation in a partially protected place in compliance with EN 297
pr A6, for temperatures to -5°C. It is advisable to install the boiler under the slope of a
roof, inside a balcony or in a sheltered recess.
Therefore the place of installation must be free of dust, flammable materials or objects
or corrosive gases.
The boiler is arranged for wall mounting and comes standard with a hooking bracket. Fix
the bracket to the wall according to the measurements given in the cover drawing and
hook the boiler on it. A metal template for marking the drilling points on the wall is avail-
able by request. The wall fixing must ensure stable and effective support for the gener-
ator.

A

If the unit is enclosed in a cabinet or mounted alongside, a space must be pro-
vided for removing the casing and for normal maintenance operations

3.3 Plumbing connections
Important

B

The safety valve outlet must be connected to a funnel or collection pipe to pre-
vent water spurting onto the floor in case of overpressure in the heating circuit.
Otherwise, if the discharge valve cuts in and floods the room, the boiler manu-
facturer cannot be held liable.

B

Before making the connection, check that the unit is arranged for operation with
the type of fuel available and carefully clean all the system pipes.

Carry out the relevant connections according to the cover diagram and the symbols giv-
en on the unit.

Note:

 The unit has an internal bypass in the heating circuit.

Water system characteristics

In the presence of water harder than 25° Fr (1°F = 10ppm CaCO

3

), use suitably treated

water in order to avoid possible scaling in the boiler.

Antifreeze system, antifreeze fluids, additives and inhibitors

When necessary, antifreeze fluids, additives and inhibitors can be used only if the man-
ufacturer of such fluids or additives guarantees that they are suitable and do not cause
damage to the exchanger or other components and/or materials of the boiler and system.
Do not use generic antifreeze fluids, additives or inhibitors that are not specific for use in
heating systems and compatible with the materials of the boiler and system.

3.4 Gas connection

The gas must be connected to the relevant union (see figure on cover) in conformity with
the current regulations, with a rigid metal pipe or with a continuous surface flexible s/steel
tube, installing a gas cock between the system and boiler. Make sure all the gas connec-
tions are tight.

3.5 Electrical connections
Important

B

The unit must be connected to an efficient earthing system in conformity with
current safety regulations. Have the efficiency and suitability of the earthing
system checked by professionally qualified personnel; the Manufacturer de-
clines any liability for damage caused by failure to earth the system.
The boiler is prewired and provided with a "Y" type cable (without plug) for con-
nection to the electric line. The connections to the power supply must be per-
manent and equipped with a double-pole switch with contact opening distance
of at least 3 mm, installing fuses of max. 3A between the boiler and the line.
Make sure to respect the polarities (LINE: brown wire / NEUTRAL: blue wire /
EARTH: yellow/green wire) in connections to the electric line.

B

The unit's power cable must not be replaced by the user; if damaged, switch
the unit off and have the cable replaced by professionally qualified personnel.
If replacing the power cable, only use 

"HAR H05 VV-F"

 3x0.75 mm2 cable with

max. ext. diameter of 8 mm.

Heating temperature setting

Adjustment can be made from the Remote Timer Control menu and the 
boiler control panel.

Hot water temperature adjustment

Adjustment can be made from the Remote Timer Control menu and the 
boiler control panel.

Summer/Winter Switchover

Summer mode has priority over a possible Remote Timer Control heat-
ing demand.

Eco/Comfort selection

Adjustment can only be made from the boiler control panel.

20

30

40

50

60

70

80

90

85

20

30

40

50

60

70

80

90

85

1

2

3

4

5

6

8

9

10

7

1

2

3

4

5

6

8

9

10

7

OFFSET = 20

OFFSET = 40

A

B

2

1

Summary of Contents for TAURA D MCS

Page 1: ...24 5 24 5 24 5 30 A B C D E F 60 61 59 80 5 400 700 63 mm 84 mm 87 mm 108 mm 763 mm 784 mm 764 mm 785 mm 68 89 cod 010007X0 cod 8 52289 0 68 89 cod 010007X0 cod 8 52289 0 IT ISTRUZIONE PER L USO L INS...

Page 2: ...ione multi funzione 12 Indicazione modalit Eco Economy 15 Indicazione bruciatore acceso e livello di potenza attuale Lampeggiante du rante la funzione anomalia combustione 16 Connessione Service Tool...

Page 3: ...a minima di 5 C Si consiglia di installare la caldaia sotto lo spiovente di un tetto all interno di un balcone o in una nicchia riparata Il luogo di installazione deve comunque essere privo di polveri...

Page 4: ...oggetto Rispettare inoltre le disposizioni inerenti il posizionamento dei terminali a parete e o tetto e le distanze minime da finestre pareti aperture di aerazione ecc Diaframmi Per il funzionamento...

Page 5: ...i separatamente EN 1856 1 B2X Aspirazione dal locale di installazione e scarico a parete o tetto IMPORTANTE IL LOCALE DEVE ESSERE DOTATO DI VENTILAZIONE APPROPRIATA Modello Massima lunghezza consentit...

Page 6: ...i decrementi di 1 o 2 unit del parametro q02 attraverso la pressione dei tasti sanitario dopo ogni modifica il valore viene memorizzato atten dere 10 secondi affinch la pressione si stabilizzi Premere...

Page 7: ...i terra Verificare che il valore di pressione gas per il riscaldamento sia quello richiesto Verificare che non vi siano liquidi o materiali infiammabili nelle immediate vicinanze della caldaia Verific...

Page 8: ...cheda Verificare la scheda A06 Mancanzafiammadopofase di accensione Bassa pressione nell impianto gas Verificare la pressione dal gas Taratura pressione minima brucia tore Verificare le pressioni F07...

Page 9: ...URA D 32 MCS 5 2 Schemi idraulici fig 23 Circuito Riscaldamento fig 24 Circuito Sanitario 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19 26 3...

Page 10: ...bar 1 5 1 5 Portata gas max G20 m3 h 2 73 3 64 Portata gas min G20 m3 h 0 88 1 22 Ugelli bruciatore G31 n x 11 x 0 79 15 x 0 79 Pressione gas alimentazione G31 mbar 37 37 Pressione gas max al bruciato...

Page 11: ...Schema elettrico fig 29 Circuito elettrico A Attenzione Prima di collegare il termostato ambiente o il cronocomando UHmoto togliere il ponticello sulla morsettiera 81 1kW L N 230V 50 Hz 16 N L 32 L N...

Page 12: ...unction 16 Service Tool connection 17 Water gauge Indication during operation Heating During a heating demand generated by Room Thermostat or Remote Timer Control the display shows the actual heating...

Page 13: ...ith EN 297 pr A6 for temperatures to 5 C It is advisable to install the boiler under the slope of a roof inside a balcony or in a sheltered recess Therefore the place of installation must be free of d...

Page 14: ...instructions Also comply with the instructions on the positioning of wall and or roof terminals and the minimum distanc es from windows walls ventilation openings etc Baffles Boiler operation requires...

Page 15: ...EN 1856 1 B2X Intake from installation room and wall or roof exhaust IMPORTANT THE ROOM MUST BE PROVIDED WITH APPROPRIATE VENTILATION Model Max permissible length TAURA D 24 MCS 60 meq TAURA D 32 MCS...

Page 16: ...reading is different from the nominal maximum pressure pro ceed by increases decreases of 1 or 2 units of parameter q02 by pressing the DHW buttons the value is stored after each modification wait 10...

Page 17: ...he fuel circuit and water systems Check the efficiency of the flue and air fume ducts while the boiler is working Make sure the water is circulating properly between the boiler and the systems Make su...

Page 18: ...Check the fan Card fault Check the card A06 No flame after the ignition phase Low pressure in the gas system Check the gas pressure Burner minimum pressure setting Check the pressures F07 Card paramet...

Page 19: ...TAURA D 32 MCS 5 2 Plumbing diagrams fig 23 Heating Circuit fig 24 DHW Circuit 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19 26 36 16 5 20 2...

Page 20: ...at burner G20 mbar 1 5 1 5 Max gas delivery G20 m3 h 2 73 3 64 Min gas delivery G20 m3 h 0 88 1 22 Burner nozzles G31 no x 11 x 0 79 15 x 0 79 Gas supply pressure G31 mbar 37 37 Max gas pressure at b...

Page 21: ...5 5 Wiring diagram fig 29 Electrical circuit A Attention Before connecting the room thermostat or the remote timer FRQtrol remove the jumper on the terminal block 81 1kW L N 230V 50 Hz 16 N L 32 L N T...

Page 22: ...dication multifonctions 12 Indication fonction Eco Economy 15 Indication br leur allum et niveau de puissance actuelle clignotant pendant la fonction anomalie combustion 16 Raccordement Service Tool 1...

Page 23: ...mur elle est quip e d une s rie d triers de fixa tion Fixer l trier au mur conform ment aux cotes indiqu es sur le dessin de couverture et y accrocher la chaudi re Un gabarit m tallique permettant de...

Page 24: ...ortent En outre respecter le positionnement des terminaux muraux et ou sur le toit et les distances mini males d une fen tre adjacente sous une bouche d a ration d un angle de l difice etc Diaphragmes...

Page 25: ...1856 1 B2X Aspiration du local de la chaudi re et vacuation murale ou sur le toit IMPORTANT LE LOCAL DOIT TRE DOT D UN DISPOSITIF DE VENTILATION APPROPRI Mod le Longueur maximale admissible TAURA D 2...

Page 26: ...ou r duire le param tre q02 d 1 ou 2 unit s en appuyant sur les tou ches Sanitaire la valeur est m moris e apr s chaque modification attendre 10 secondes pour que la pression se stabilise Appuyer sur...

Page 27: ...e V rifier que la pression de gaz pour le chauffage est bien celle requise V rifier qu il n y ait pas de liquides ou de mat riaux inflammables dans les alentours imm diats de la chaudi re V rification...

Page 28: ...lie carte V rifier la carte A06 Absence de flamme apr s la phase d allumage Basse pression dans l installation d alimentation du gaz V rifier la pression du gaz R glage de la pression minimale br leur...

Page 29: ...RA D 32 MCS 5 2 Sch mas hydrauliques fig 23 Circuit Chauffage fig 24 Circuit Sanitaire 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19 26 36 1...

Page 30: ...r G20 mbar 12 0 12 0 Pression gaz mini au br leur G20 mbar 1 5 1 5 D bit gaz maxi G20 m h 2 73 3 64 D bit gaz mini G20 m h 0 88 1 22 Gicleurs br leur G31 nbre x 11 x 0 79 15 x 0 79 Pression gaz alimen...

Page 31: ...5 Sch ma lectrique fig 29 Circuit lectrique A Attention Avant de brancher le thermostat d ambiance ou la chronocom mande distance d faire le pontage sur le bornier 81 1kW L N 230V 50 Hz 16 N L 32 L N...

Page 32: ...Higr metro Indicaci n durante el funcionamiento Calefacci n Durante la demanda de calefacci n generada por termostato de ambiente o reloj pro gramador a distancia en la pantalla 11 fig 1 aparecen la...

Page 33: ...un balc n o en un nicho resguardado En cualquier caso la caldera se ha de instalar en un lugar donde no haya polvo gases corrosivos ni objetos o materiales inflamables La caldera preparada para fijars...

Page 34: ...sposiciones sobre la posici n de los terminales en la pared o en el techo y las distancias m nimas a ventanas paredes aberturas de airea ci n etc Diafragmas Para utilizar la caldera es necesario monta...

Page 35: ...ambiente de instalaci n y evacuaci n en pared o techo IMPORTANTE EL LOCAL DEBE ESTAR DOTADO DE VENTILACI N APROPIADA Modelo Longitud m xima permitida TAURA D 24 MCS 60 meq TAURA D 32 MCS 48 meq Diafr...

Page 36: ...la memoria esperar 10 segundos a que la presi n se estabilice Pulsar la tecla de calefacci n 3 fig 1 La tarjeta se dispone en la configuraci n del par metro q01 y al presionar la te clas del agua sani...

Page 37: ...i n el ctrica y la puesta a tierra sean adecuadas Controlar que la presi n del gas de calefacci n tenga el valor indicado Controlar que no haya l quidos o materiales inflamables cerca de la caldera Co...

Page 38: ...Controlar la presi n del gas Regulaci n de la presi n m nima del quemador Controlar las presiones 3 0 5 F07 Anomal a de los par me tros de latarjeta Par metro de latarjeta mal confi gurado Controlare...

Page 39: ...RA D 32 MCS 5 2 Esquemas hidr ulicos fig 23 Circuito de calefacci n fig 24 Circuito de AS 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19 26 3...

Page 40: ...nima en el quemador con G20 mbar 1 5 1 5 Caudal m ximo gas G20 m3 h 2 73 3 64 Caudal m nimo gas G20 m3 h 0 88 1 22 Inyectores quemador G31 n x 11 x 0 79 15 x 0 79 Presi n de alimentaci n gas G31 mbar...

Page 41: ...el ctrico fig 29 Circuito el ctrico A Atenci n Antes de conectar el termostato de ambiente o el reloj programa dor a distancia quitar el puente de la regleta de conexiones 81 1kW L N 230V 50 Hz 16 N...

Page 42: ...UPRVW WK F URX WR WKOHFHLULVW ULR PH FUR QRGLDN SWK VWKQ RT QK HPIDQ HWDL K WU FRXVD THUPRNUDV D WK9 SDURF 9 T UPDQVK9 OHSW 11 fig 1 NDL NDW WR GL VWKPD DQDPRQ 9 JLD T UPDQVK K QGHL K d2 1HU RLNLDN 9...

Page 43: ...L K HJNDW VWDVK WRX O EKWD N WZ DS VW JDVWUR VH PSDON QL VH SURVWDWHXP QK HVRF 2 F UR9 HJNDW VWDVK9 GHQ SU SHL QD FHL VN QK H IOHNWD DQWLNH PHQD XOLN GLD EUZWLN D ULD 2 O EKWD9 SURRU HWDL JLD HSLWR FL...

Page 44: ...HS VK9 WL9 GLDW HL9 SRX DIRUR Q WKQ WRSRT WKVK WZQ DSRO HZQ WZQ DJZJ Q VWRQ WR FR NDL VWKQ RURI NDL WL9 HO FLVWH9 DSRVW VHL9 DS SDU TXUD WR FRX9 DQR JPDWD DH ULVPR NOS LDIU JPDWD LD WK OHLWRXUJ D WRX...

Page 45: ...NDL H DJZJ PH VZO QH9 SRX FRXQ SLVWRSRLKTH HFZULVW EN 1856 1 B2X QDUU IKVK DS WR F UR HJNDW VWDVK9 NDL H DJZJ VWRQ WR FR VWKQ RURI 6 0 17 2 2 526 35 3 1 5 7 3 5 6 0RQW OR 0 JLVWR HSLWUHS PHQR P NR9 T...

Page 46: ...L GLDIRUHWLN DS WK P JLVWK RQR PDVWLN S HVK DX VWH PHL VWH NDW 1 2 PRQ GH9 WKQ SDU PHWUR q02 SDW QWD9 WD NRXPSL QHUR RLNLDN 9 FU VK9 PHW DS N TH WURSRSR KVK K WLP DSRTKNH HWDL 3HULP QHWH 10 GHXWHU OHS...

Page 47: ...QDL VZVW HP VWH WKQ XGUDXOLN HJNDW VWDVK NDL EHEDLZTH WH WL FHL HNWRQZTH SO UZ9 R D UD9 SRX XS UFHL VWR O EKWD NDL VWKQ HJNDW VWDVK HEDLZTH WH WL GHQ XS UFRXQ GLDUUR 9 QHUR VWKQ HJNDW VWDVK VWD NXNO...

Page 48: ...VWKQ HJND W VWDVK O J WH WRQ NXNORIRUKW UD9 VWKQ HJNDW VWDVK DHU VWH WKQ HJNDW VWDVK 3 0 5 F04 NDW OOKOH9 SDU PH WURL SODN WD9 VIDOP QK U TPLVK SDUDP WURX SODN WD9 O J WH NDL WURSRSRL VWH H Q DSDL WH...

Page 49: ...8GUDXOLN GLDJU PPDWD 23 NOZPD T UPDQVK9 24 NOZPD QHUR RLNLDN 9 FU VK9 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81...

Page 50: ...F DHU RX G20 m3 h 2 73 3 64 O FLVWK SDURF DHU RX G20 m3 h 0 88 1 22 0SHN NDXVW UD G31 DU x 11 x 0 79 15 x 0 79 3 HVK DHU RX WURIRGRV D9 G31 mbar 37 37 0 JLVWK S HVK DHU RX VWRQ NDXVW UD G31 mbar 35 0...

Page 51: ...RORJLN GL JUDPPD 29 OHNWULN N NOZPD A 3URVRF 3ULQ VXQG VHWH WR THUPRVW WK F URX WR WKOHFHLULVW ULR PH FURQRGLDN SWK DIDLU VWH WR EUDFXNXNOZW UD DS WKQ SODN WD DNUR GHNW Q 81 1kW L N 230V 50 Hz 16 N L...

Page 52: ...t Clipe te intermitent n timpul func iei de anomalie ardere 16 Conexiune Service Tool 17 Hidrometru Indica ii n timpul func ion rii nc lzire n timpul cererii de nc lzire generat de Termostatul de came...

Page 53: ...locul de instalare nu trebuie s existe praf obiecte sau materiale inflamabile sau gaze corozive Centrala este proiectat pentru instalarea suspendat pe perete i e dotat n serie cu un cadru de fixare F...

Page 54: ...prevederile respective Respecta i de asemenea dispozi iile referitoare la po zi ionarea terminalelor pe perete i sau acoperi i distan ele minime fa de ferestre pe re i deschideri de aerisire etc Diaf...

Page 55: ...rat EN 1856 1 B2X Admisie din nc perea de instalare i evacuare pe perete sau pe acoperi IMPORTANT NC PEREA TREBUIE S FIE DOTAT CU O AERISIRE ADECVAT Model Lungime maxim permis TAURA D 24 MCS 60 meq TA...

Page 56: ...iecare modificare valoarea este me morizat a tepta i 10 secunde pentru ca presiunea s se stabilizeze Ap sa i tasta pentru nc lzire det 3 fig 1 Cartela ajunge la setarea q01 ap s nd pe tastele pentru a...

Page 57: ...tare Verifica i ca valoarea presiunii gazului pentru circuitul de nc lzire s fie cea nece sar Verifica i ca n imediata apropiere a centralei s nu existe lichide sau materiale in flamabile Verific ri n...

Page 58: ...Verifica i ventilatorul Anomalie cartel Verifica i cartela A06 Lipsa fl c rii dup faza de aprindere Presiune sc zut n instala ia de gaz Verifica i presiunea gazului Calibrare presiune minim la arz tor...

Page 59: ...32 MCS 5 2 Scheme hidraulice fig 23 Circuitul de nc lzire fig 24 Circuitul de ap cald menajer 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19...

Page 60: ...20 mbar 1 5 1 5 Debit gaz max G20 m3 h 2 73 3 64 Debit gaz min G20 m3 h 0 88 1 22 Duze arz tor G31 nr x 11 x 0 79 15 x 0 79 Presiune gaz alimentare G31 mbar 37 37 Presiune gaz max la arz tor G31 mbar...

Page 61: ...5 5 Schem electric fig 29 Circuitul electric A Aten ie nainte de a racorda termostatul de camer sau cronocomanda la distan scoate i puntea de pe panoul de borne 81 1kW L N 230V 50 Hz 16 N L 32 L N T...

Page 62: ...U 1 2 2 1 TAURA D MCS EN 297 A6 5 C 2 2 1 1 1 2 3 4 5 6 7 10 11 12 Eco 15 16 17 11 1 d2 11 1 SA d1 cap 4 4 11 1 d3 d4 2 3 5 7 1 5 2 7 1 5 3 B sez 3 3 2 4 6 1 2 10 1 6 1 2 30 C 85 C 3 4 1 45 C 4 40 C 5...

Page 63: ...5 6 1 CU 1 1 1 10 0 3 1 OF 1 1 6 5 6 1 6 A 1 1 2 7 1 0 F37 1 7 A B 7 3 3 1 3 2 2009 142 EN 297 pr A6 5 C A 3 3 B B 25 Fr 1 F 10 CaCO3 3 4 3 5 B Y 3 3 A B HAR H05 VV F 3x0 75 2 8 20 30 40 50 60 70 80...

Page 64: ...4 5 6 C1X C3X 010006X0 08522870 10 010008X0 08522880 11 010007X0 12 08522890 13 60 100 80 125 5 10 90 1 0 5 45 0 5 0 25 0 2 TAURA D 24 MCS 43 TAURA D 32 MCS 45 0 3 TAURA D 24 MCS 43 TAURA D 32 MCS 45...

Page 65: ...0 5 0 5 1 0 1 1KWMA83A 1 0 1 0 2 0 2 1KWMA06K 2 0 2 0 4 0 45 1KWMA01K 1 2 2 2 45 1KWMA65A 1 2 2 2 90 1KWMA02K 2 0 3 0 90 1KWMA82A 1 5 2 5 90 1KWMA70U 1 5 2 5 1KWMA16U 0 2 0 2 1KWMA55U 3 0 T 1KWMA05K...

Page 66: ...T 3 4 1 5 TEST 15 B TEST cap 4 1 Eco Comfort 2 q02 q02 1 2 10 3 1 q01 q01 1 2 10 Eco Comfort 2 TEST TEST cap 4 1 TEST sez 4 1 3 1 00 100 5 TEST sez 4 1 10 8 b bar 18 A B I R S 19 TYPE SGV100 Pi 65 24...

Page 67: ...85 C 80 C 80 C P06 0 100 100 100 P07 b02 1 0 0 0 1 2 5 3 10 4 20 b02 2 0 0 1 2 5 3 10 4 20 b02 3 0 4 C 2 C b02 4 0 4 C 2 C P08 b02 1 0 60 30 30 b02 2 0 60 60 b02 3 0 60 30 b02 4 0 60 30 P09 b02 1 50...

Page 68: ...11 1 A RESET 6 1 1 RESET F 9 5 10 cap 5 A01 A02 A03 3 0 5 F04 F05 A06 F07 A09 F10 1 F11 F14 2 A16 F20 A21 F20 10 F20 A23 A24 F34 180 F35 F37 F39 A41 F42 F43 H2 O F50 A51 5 32 7 36 8 38 9 42 10 44 11 5...

Page 69: ...32 MCS 5 2 23 24 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 56 29 187 42 28 27 19 26 36 16 5 20 21 22 81 114 14 10 8 7 38 9 11 32 44 74 278 340 278 11 9 8 10...

Page 70: ...1 35 G20 20 0 20 0 G20 12 0 12 0 G20 1 5 1 5 G20 3 2 73 3 64 G20 3 0 88 1 22 G31 x 11 x 0 79 15 x 0 79 G31 37 37 G31 35 0 35 0 G31 5 0 5 0 G31 2 00 2 69 G31 0 65 0 90 3 3 PMS 0 8 0 8 C 90 90 tmax 1 0...

Page 71: ...TAURA D MCS 71 RU cod 3541A222 Rev 05 04 2013 5 5 29 A 81 1kW L N 230V 50 Hz 16 N L 32 L N T T 278 T 42 4 3 2 1 44 38 114 ABM01 72 139 138...

Page 72: ...i a Gas 2009 142 Direttiva Rendimenti 92 42 Direttiva Bassa Tensione Direttiva Compatibilit Elettromagnetica IT EN Declaration of conformity Manufacturer declares that this unit complies with the foll...

Page 73: ...r c acest aparat este n conformitate cu urm toarele directive CEE Directiva Aparate cu Gaz 2009 142 Directiva Randament 92 42 Directiva Joas Tensiune Directiva Compatibilitate Electromagnetic RO CEE 2...

Page 74: ......

Page 75: ......

Page 76: ...RUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO LAMBORGHINI CALOR S p A VIA STATALE 342 44047 DOSSO FERRARA ITALIA TEL ITALIA 0532 359811 EXPORT 0532 359...

Reviews: