DORA TECH
90 LT - 120 LT
97
cod. 3540000800 - Rev. 02 - 09/2023
EN
rious water leakage;
• Sufficiently illuminated (where required);
• Protected from frost and keep dry.
6.5 WALL FIXING
The product must be installed on a solid wall that is not subject
to vibrations. For securing choose the most suitable type of
expansion plug according to the specific wall type.
fig. 50 - Drilling indication
• Hook the boiler with the special fastening bracket (fig. 51).
fig. 51 - Wall fixing
6.6 AERAULIC CONNECTIONS
ATTENZIONE
In many images of this document
the position of the air ducts are
schematized at the top and bot-
tom, in reality for the purposes
of correct installation we recom-
mend positioning the ducts side
fig. 52– Arrangement of air channels
In addition to the spaces indicated in section 6.4, the heat pump
requires adequate air ventilation.
• Create a dedicated air duct as indicated in fig. 53.
fig. 53- Example of air outlet connection
Install each air duct making sure that: