DORA
200 LT-S - 260 LT-S - 200 LT - 260 LT
81
cod. 3541T640 - Rev. 03 - 05/2020
EN
To use the equipment in both these configurations it is neces-
sary to set the parameter
P12 = 2
and
P16 = 2
(see par. 7.1).
fig. 20
fig. 21
Legend (fig. 19, fig. 20 and fig. 21)
1
Cold water inlet
2
Solar coil outlet
3
Solar coil outlet
4
Recirculation
5
Hot water outlet
8
Solar thermal coil
10
Drain valve
16
Recirculating pump
17
Check valve
18
Automatic thermostatic
mixing device
19
Solar collector
20
Solar collector probe
(PT1000 not supplied*)
21
Solar collector shutter
22
DHW puffer
23
Solar coil probe
(not supplied)
24
Heat pump
A
Probe holder
* We advise to use solar collector probe PT1000 (cod.
LAMBORGHINI - 043007X0)
5.7 Electrical connections
The product comes already wired for the mains supply. It is
powered via a flexible cable and a combination plug/socket (fig.
22and fig. 23). For connection to the mains, a Schuko socket
with ground and separate protection is required.
ATTENTION!: The power supply line to which the
equipment will be connected must be protected
by a suitable differential switch.
The type of differential must be chosen accord-
ing to the type of electrical devices used by the
overall plant.
For the mains connection and the safety devices
(e.g. differential switch), comply with IEC stan-
dard 60364-4-41.
fig. 22 - Schuko socket
fig. 23 - Unit plug