background image

 

Vega 900 Handbook 

                                                                                         �

                                                                   Part Number 17155

Primary Options

Specified Option

Pin 5 Logic 0

Pin 6 Logic 1

Inhibit

Outputs OFF

Outputs OFF

Enable

Outputs ON

Outputs ON

Secondary Options

Module Good

Inhibit Anode

Mating input faston connectors

Brand

Colour

Wire size (awg)

Part number

Current rating

Amp

Red

22 - 18

2-520407-2

15A

Amp

Blue

16 - 14

3-520408-2

15A

Input Connections  

Input tabs - 6.3mm x 0.8mm, tin plated brass, rated 15A.  Internal fuse (F1)  16A/250V fast acting 

HBC fuse 6.3x32mm 

Input Screw Terminals:  6-32 screws with 8.25mm spacing between screw head centres.  Screw 

head diameter is 6.6mm.   

Input IEC 320: Rated 10A/250Vac (15A/132Vac)

Connection details

Inhibit

Remote Sense +VE

Inhibit/Enable Anode

Remove Sense -VE

Inhibit/Enable 

Share

Com-

Share

Module Good Collector

Remote Sense +VE
Analogue programming 

 

 

(Voltage or resistive with respect to comman) 

Module Good Emitter

Single output wide range programmable module

Inhibit/Enable Anode

Inhibit/Enable Cathode

0-32K      resistance 

0-5V external voltage prog.pin

Prog signal return

Inhibit/Enable Anode
Inhibit/Enable Cathode
0-5V current prog. pin
Prog. signal return
Prog. signal return

Transistor ON (saturated) when 

module is GOOD.

Module is GOOD when output 

voltage is between (88-96%) and 

(104-112%) of its set voltage.

Max Vce 70V  

Vsat 

<

0.4V at  

 

 

1mA current

Module good Collector

Module good Emmitter

Single output module digital option

TWIN Output Module ”R” Option

TWIN Output Module ”N” Option

Inhibit 

Anode

Remote Sense -VE

Inhibit Cathode

Remote Sense -VE

Inhibit 

Anode

Inhibit Cathode

Module Good Collector

Remote Sense +VE

Module Good 

Module Good Collector

Remote Sense +VE

Module Good 

CH1

CH2

Remote Sense +VE

Remote Sense +VE

Remote Sense -VE

Remote Sense -VE

C  H  1

C  H  2

I

nternally is a 390 

resistor is series with  

diode of an optocoupler.  Drive 

2mA to inhibit module (max 

13mA).

INH A

INH C

390

VF=1.1V

Remote Sense Option

SINGLE Output Module ”N” Option

Remote Sense -VE

Inhibit Cathode

Module Good Collector

Share
Share

Inhibit Anode

Module Good Collector

Module Good Emitter

Internally is the output of an opto-isolated transistor.  

 Transistor “on”=AC + Temp O.K.  Vce max = 30V Ic max =  

5mA, 5mS warning of thermal shutdown or loss of AC.

Logic 0 = 0-0.8V. 

Logic 1 = 2.0 - 5.0V 

with respect to 0V (Pin 3)

AC + Temp Fail, E

AC + Temp OK

AC + Temp Fail, C

AC + Temp Fall, C

AC + Temp Fall, E

0V

Aux Voltage

INH/ENA Logic 0 (TTL Logic Levels)

INH/ENA Logic 1(TTL Logic Levels)

Pin 1

Pin 6

Maximum Torque Settings for Output Screw Terminals 

M3 - 0.75Nm       M4 - 1.5Nm       M5 - 2.0Nm 

Output Connections 

Output Connector Ratings:  Single slot, single output modules (B, C, L modules):  Two 6.35mm  

fast-ons per output each rated at 18A or M4 screw terminals rated at 35A.  Single slot, twin output 

modules (H modules);  One 6.35mm fast-on per output rated at 18A or M3 screw terminals rated at 

15A.  Dual slot, single output modules (D, E modules):  Two 9.5mm fast-ons per output each rated 

at 32A, or M5 screw terminals rated at 90A

Special instructions for applications covered by IEC/EN/UL/CSA61010-1.

Whilst all individual module single outputs are classed as SELV outputs in accordance with IEC/EN/

UL/CSAEN60950-1 (<60Vdc or 42.4V peak) serried  combinations of these modules may exceed 

these values and become hazardous output voltages.  For IEC/EN/UL/CSA61010-1 the equivalent 

limits are 70Vdc, 33Vrms or 46.7V peak.    

Under single fault conditions these limits are increased for IEC/EN/UL.CSA61010-1 and UL3101-1 

to 140Vdc, 55Vrms or 78V peak.  Provided these levels are not exceeded, the outputs are not 

considered hazardous for IEC/EN/UL/CSA61010-1 

DO NOT USE MOUNTING SCREWS WHICH PENETRATE THE UNIT BY MORE THAN 4.5 MM.

 

Weight 2 Kg dependent upon configuration.

Mechanical parameters

If the equipment is used in a manner not specified by the manufacturer, the protection 

provided by the equipment may be impaired.

Applicable to products with L, R and T filter options only. 

i)  These products are designed for continuous operation within an overall enclosure, and must 

be mounted such that access to the mains terminals isrestricted.  See Clause 16, IEC/EN/UL/

CSA60601-1,  

ii)  These products are NOT suitable for use in the presence of flammable anaesthetic mixtures 

with air or with oxygen or with nitrous oxide. 

iii)   These products are classed as ordinary equipment according to IEC/EN/UL/CSA60601-1 and 

are NOT protected against the ingress of water. 

iv)  Connect only apparatus complying with IEC/EN/UL/CSA60601-1, to the signal ports. 

v)  Except for permanently installed equipment as defined in Clause 57.6 of IEC/EN/UL/

CSA60601-1, the overall equipment in which these products are installed must have double pole 

fusing on the input mains supply or DC supply as appropriate.  The products themselves have 

single pole fusing in the live line or positive DC line as appropriate. 

vi)   Reference should be made to local regulations concerning the disposal of these products at 

the end of their useful life.

Special instructions for medical applications (IEC/EN/UL/CSA60601-1) 

Input Filter Options
Option

Max. Leakage at 264VAC,63Hz

RFI EN55022 Class

Standard

1.5mA max

B/A

M

650uA max

A

L

290uA max

A

R

175uA max

Above A

T

60uA max

Above A

Note: When primary options EW or FW are fitted the above values increase 100uA

Reviews: