Indication
Lead Acid
Nickel Cadmium
First time
charging
Yellow
“CHARGING”
Charge to 28.20
Volts, then charge
for another 60
minutes OR until
battery reaches
28.60 Volts. Then
shut down.
Charge to 28.50 Volts,
then charge for another
60 minutes OR until
battery reaches 30.00
Volts. Then shut
down.
First Idle
Period
Green
“READY”
Watch battery self-
discharge until it
drops below 25.30
Volts.
Watch battery self-
discharge until it drops
below 25.30 Volts.
Second
time
charging
Yellow
“CHARGING”
Charge to 28.20
Volts, then charge
for another 30
minutes OR until
battery reaches
28.60 Volts. Then
shut down.
Charge to 28.50 Volts,
then charge for another
30 minutes OR until
battery reaches 30.00
Volts. Then shut
down.
Second
Idle
Period
Green
“READY”
Watch battery self-
discharge until it
drops below 25.30
Volts.
Watch battery self-
discharge until it drops
below 25.30 Volts.