background image

7

6

4

1

Outlet

Inlet

Solids Purge

A

B

C

Inlet/Outlet Pressure Gauges 
with Petcock Valves

  

Included as standard; Install at 
both inlet and outlet for proper 
flow verification (see “Flow vs. 
Pressure Loss”, page 3)

Inspection/Drain Plug

1/2-inch NPT female; provides 
access to upper chamber for 
inspection of slot area; also 
allows for draining the upper 
chamber if necessary

Rigid Coupling Connection 

 

Provides for complete access
to the upper chamber, 
acceleration slots and internal 
separation barrel; standard EPDM 
gasket - also available in Nitrile, 
Silicone, Fluoroelastomer,
Black Neoprene or White Nitrile;
model JPX-2650 and larger
uses flange
 

Lifting Rings

For installation purposes

Connection Spool

When removed, provides space for 
accessing internal of separator via 
rigid coupling. Not included with 
separator, available separately

Hand-Hole Inspection Port

Provides access to collection 
chamber; Neoprene gasket

Vortube 

Piping provided by LAKOS

Dimensions

in

72

78

93-1/2 

105-3/4 

126-3/8 

139-3/4 

155-1/2 

194-1/2 

229

mm

1829

1930

2375 

2686 

3210

3351 

3950

4940 

5817

in

16

18 

20 

22 

26 

32 

36 

44 

48

mm

406

457

508 

559 

660 

813 

914 

1118

1219

in

21

21 

24 

24

30 

33 

38 

51 

60 

mm

533

534 

610

610 

762 

838 

965 

1295 

1524 

in

10-9/16

13 

12-1/2 

14-7/8 

17-3/4 

20 

23 

29 

32-3/4

mm

268

330 

318 

378 

451 

508 

584 

734 

832

in

10-3/4

12-3/4 

14 

16 

20 

24 

28 

36 

42

mm

273

324

356 

406 

508 

610 

711 

914 

1067

Model

JPX-0200-V

JPX-0285-V

JPX-0450-V

JPX-0650-V

JPX-1160-V

JPX-1850-V

JPX-2650-V

JPX-4200-V

JPX-6700-V

High Flow Rates

Vertical Profile

Recommended
Direction
of Inlet/Outlet
Piping to Control
Vibration

Inlet

Outlet

1

2

3

4

5

6

7

3

6

5

3

4

2

Top Views

Base Plate

A

B

C

D

E

Page 7

D

E

Dimensions for reference only. 
Consult factory when pre-plumbing.

Summary of Contents for JPX

Page 1: ...Rigid couplings for fast and easy internal access Swirlex internal accelerating slots for optimum solids removal performance patented optional annular transfer ring for handling larger solids fibrous materials Vortube for enhanced solids separation collection patented Grooved inlet outlet connections for easy installation optional flanged connections also available In line inlet outlet configurati...

Page 2: ...ge valve for servicing Grooved end connections at inlet outlet for fast secure easy installation Optional ANSI or DIN flanges also available Pressure gauges with petcock valves included as standard to monitor proper flow range see Flow vs Pressure Loss page 3 Outlet Inlet Internal Swirlex tangential slots accelerate flow to maximize separation of solids with reduced pressure loss Particles are sep...

Page 3: ...terials available consult factory Paint coating Acrylic urethane spray on royal blue 1 1 1 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 Specifications Flow Range U S gpm m3 hr gal liters lbs kg kg lbs Model Weight Weight with Water Collection Chamber Capacity Inlet Outlet Grooved Coupling 1 1 2 1 1 2 1 1 2 1 1 2 2 2 3 3 JPX 0004 JPX 0010 JPX 0016 JPX 0028 JPX 0038 JPX 0060 JPX 0085 JPX 0130 JPX 0200 JPX 02...

Page 4: ...ressure of at least 5 psi 3 bar Winterizing is important if the LAKOS Separator is to remain idle in freezing temperatures Drain liquid as necessary to avoid expansion of water to ice and related damages Maintenance Purging Installation Instructions 1 LAKOS JPX Separators must be purged regularly to remove the separated solids from the temporary collection chamber 2 All purge hardware should be in...

Page 5: ...ification see Flow vs Pressure Loss page 3 Rigid Coupling Connection Provides for complete access to the upper chamber acceleration slots and internal separation barrel 2 piece standard EPDM gasket also available in Nitrile Silicone Fluoroelastomer or White Nitrile Vortube Piping provided by LAKOS Rigid Coupling Access Provides full access to collection chamber area for inspection serving standard...

Page 6: ...rd Install at both inlet and outlet for proper flow verification see Flow vs Pressure Loss page 3 Inspection Drain Plug 1 2 inch NPT female provides access to upper chamber for inspection of slot area also allows for draining the upper chamber if necessary Rigid Coupling Connection Provides for complete access to the upper chamber acceleration slots and internal separation barrel standard EPDM gas...

Page 7: ...a rigid coupling Not included with separator available separately Hand Hole Inspection Port Provides access to collection chamber Neoprene gasket Vortube Piping provided by LAKOS Dimensions in 72 78 93 1 2 105 3 4 126 3 8 139 3 4 155 1 2 194 1 2 229 mm 1829 1930 2375 2686 3210 3351 3950 4940 5817 in 16 18 20 22 26 32 36 44 48 mm 406 457 508 559 660 813 914 1118 1219 in 21 21 24 24 30 33 38 51 60 m...

Page 8: ...ve size ______ Pneumatic Pinch Valve Compressed air shall be provided to actuate this full port valve at appropriate intervals and duration in order to efficiently and regularly purge solids from the separator s collection chamber System shall include a pressure regulator for proper modulation of air pressure Valve liner is natural gum rubber other liner materials available Valve size ______ Pneum...

Reviews: