Technical Data PHONE-AMP G109
All measurement RMS unwtd., 20 Hz - 20 kHz, referred to +6 dBu
Pre-Gain set to 0 dB, Lo-Cut set to DC
Inputs G109-S:
2 x Cinch, unbalanced
Inputs G109-P:
2 x XLR female, bal. + 2 x Cinch
Max. Input Voltage:
+ 21 dBu, Impedanz 10 kOhms
Input Impedance:
10 kohms
Nom. Input Sensitivity:
+6 dBu
Amplifier Gain:
+8 dB
Overall Gain with
PRE-GAIN
:
-4 / +8 / +14 dB
Frequency Range (-3 dB):
0 Hz ... 50 kHz (- 0,5 dB) … 200 kHz
Slew Rate:
8 V / usec
Dynamic Range 2x 600 R:
> 125 dB / 129 dB (A-wtd)
Dynamic Range 2x 100 R:
> 122 dB / 126 dB (A-wtd)
Noise:
< -98 dBu / -101 dBu (A-wtd)
THD+N (1kHz / 2x10V / 100R = 1W)
< -100 dB / < 0.001 %
THD+N (1kHz / 2x18V / 600R = 0,5W)
< -102 dB / < 0.0008 %
Crosstalk:
< -110 dB (1 kHz) / -98 dB (15 kHz)
Output impedance:
< 0,2 Ohm
Max. Output Level:
R
L
(x 2 )
U
a
(dBu)
U
a
(V) P
a
(mW)
(1kHz / < 0.1% THD+N)
600 27,8
18,9
595
300
27,3
17,8
1056
240
26,5
16,3
1107
100
24,6
13,2
1742
60
23,1
11,1
2053
40
20,5
8,5
1806
32
18,7
6,7
1402
16
13,1
3,5
765
Mains Supply Voltage:
230 V AC / 115 VAC max. 8 VA
Case, Front, Back:
black anodized aluminium
Dimensions:
168 x 49 x 145 mm (W x H x D)