Lake Lite Inc.
105 W Simon St
Laotto, IN 46763
Phone: 260-918-2758
Fax: 260-918-3540
E-mail [email protected]
www.lakelite.com
TIME
LED COLOR
DESCRIPTION
Any
RED - FLASHING
Extremely Low Battery
OR (BLOWN FUSE)
OR (Backwards / No Connection)
Any
RED - CONSTANT
Very Low Battery Level –
Limit Battery Use
Any
ORANGE - CONSTANT
Medium Battery Level –
Charge Battery
Any
GREEN - CONSTANT
High Battery Level – Good!
ANY
GREEN - FLASHING
Over Voltage Detected:
Regulator will correct back to
Green-Constant to protect
battery:
ANY
OFF
Blown Fuse
and or No Battery
Detected
Replace Fuse or Connect
Battery
Solar Charge Regulator
MODELS: LL-REG-24v-5A
TIME
LED COLOR
DESCRIPTION
DAY
BLUE - CONSTANT
(Charging) Fast Charging or
Bulk Charging
DAY
GREEN-CONSTANT
Float Charging
DAY
OFF
Check Solar Panel (Shorted / Bad or
No Connection / Bad Diode)
NIGHT
OFF
Solar Panel is NOT Charging
PRE-CHECK # 1:
Connect Regulator ONLY to Battery and confirm
Battery Status LED Turns On.
* NOTE (Solar Panel NOT Connected)
PRE-CHECK # 2:
Connect Regulator ONLY to Solar panel and
confirm Charging Status LED Turns On.
* NOTE (Battery is NOT connected)
NOTE:
If both Pre-Checks are OK: Regulator is functioning
correctly.
FLASHING RED BATTERY LED:
Likely result of a blown fuse, bad,
broken, or no connection. Correct or replace wiring.
BATTERY LED INDICATORS
Reversed Battery Polarity!
Reversed Solar Polarity!
FLOAT Charging (Battery 100%)
SOLAR LED INDICATORS
Battery Level