7. Technical specification   

 

Item 

Parameter   

Laser wavelength 

635nm 

Laser class 

Class

/Class III 

Accuracy 

±1.5mm/5m 

Leveling range 

±3° 

Temperature range 

-10℃~+45℃

 

Power 

3*AA battery 

Low voltage indication 

Power indication LED is red 

Size 

104×49×104mm   

Weight   

0.3Kg 

 

8. Maintenance 

 

 

Avoid being wet with water and rain. 

 

The instrument should be carefully operated and properly preserved, and any violent shock or falling will possibly 

result in the damage of instrument. 

 

Do  not  attempt  to  disassemble  the  instrument,  and  the  unprofessional  disassembly  will  result  in  the  damage  of 

instrument. 

 

Keep the cleanness of instrument, especially the laser output window, and remove dust by the gentle operation of 

soft clean cloth. 

 

Take the batteries out  when the  instrument is not  in use for a long time, and keep the  instrument in the carrying 

case when it is unused.

 

Summary of Contents for LS609

Page 1: ...and wide applications Features Able to project two laser lines Able to form one cross laser intersection line Self leveling with laser flashing indication if beyond range 1 4 screw thread on the bottom of the instrument Various accessories can extend the purpose of the instrument Note This manual could also apply for high output power laser 2 User safety Laser output sign is located at the output ...

Page 2: ... the battery box cover put 3 AA alkaline batteries into battery box according to polarity direction then close the battery cover Battery cover 1 4 screw thread hole 1 4 screw thread Belt slot 5 8 screw thread Strong magnet Instrument hand wheel Hanging hole Tightening knob ...

Page 3: ...ument a The instrument can be placed on the horizontal platform directly b Able to connect with bracket through 1 4 screw thread on the bottom of the instrument Set up on the tripod Attach on the steel plate Hang on the wall ...

Page 4: ...power on OFF power off ON red low voltage 4 4 Laser output control button Press for the first time the vertical line is on Press button for the second time the vertical line is off the horizontal line is on Horizontal line vertical line control button Power indication LED ...

Page 5: ...here will be a cross laser line on the wall set the center of cross line as A dot c Mark A dot and M dot on the horizontal line separately the distance between both dots is about 2 5m d Rotate the instrument make B dot 5m away A dot e Measure the distance e from M dot to the laser line f If e 1 5mm the instrument accuracy is out of tolerance it needs repair 5 2 Horizontal accuracy self check longi...

Page 6: ... Rotate the instrument by 180 make the cross dot project on staff B record b1 dot value e Move the tripod make the distance between the instrument and staff A as 0 6m make the cross dot project on staff A record a2 dot value f Rotate the instrument by 180 make the cross dot project on staff B record b2 dot value ...

Page 7: ...adjusting use the subtense 3mm hexagon spanner 2 The adjustment of both directions will influence each other When making fine adjustment in the left right direction there may be changes in fore and aft direction Also when making fine adjustment in fore and aft direction there may be changes in left right direction Accordingly please repeat the adjustment of both directions when making fine adjustm...

Page 8: ... should be carefully operated and properly preserved and any violent shock or falling will possibly result in the damage of instrument Do not attempt to disassemble the instrument and the unprofessional disassembly will result in the damage of instrument Keep the cleanness of instrument especially the laser output window and remove dust by the gentle operation of soft clean cloth Take the batterie...