2.3 Hints for Safe Operation 

 

PLEASE NOTE 

Conduct inspections on a regular time base  

This will ensure that the appropriate measures will be carried out indeed. 

The unit is operation save. It was built according to the state-of-the-art. 
Despite this the unit could cause hazards if it 

  is used in a way it was not intended for 

  is used improperly 

  is operated under unsuitable conditions 

2.3.1   Prevent Hazards 

Hazards can be prevented by safety-conscious and anticipatory behavior of staff. 
Everybody working with the unit should keep the following in mind: 

  Make this Operation Manual available for everybody at the operation site of the unit in a 

complete and perfectly readable state! 

  Use the unit exclusively for what it was intended! 

  The unit must be operational and error free. Check the condition of the unit before working with 

it and within a regular time frame. 

  Make sure that nobody can injure himself by any part of the unit! 

  Any disruption or recognizable change concerning the unit should be reported to the 

responsible person. 

  Stick to accident prevention regulations as well as any regional regulations! 

2.3.2  Hints Regarding the Electrical Equipment  

 

 

 

 

DANGER 

Danger to life through electrical shock when working on the electrical equipment of the unit! 

 Switch off the unit before starting your work! 

 Disconnect the unit from mains by pulling the mains plug! 

 Verify that the installation is dead (volt-free)! 

 Carry out earthing or short circuiting! 

When working on electrical installations the following principles should be observed: 

  Works on the electrical installations may only be accomplished by qualified electrical staff! 

  When connecting electrical equipment to mains regional regulations must be observed.  

  The unit is powered by electricity. Electrical shock hazard exists, if the electrical installations 

are defective or the insulation fails during operation. 

  When switched-off the unit is not disconnected from mains. This is only the case when the 

mains plug is pulled. 

  Any changes regarding the control elements of the unit can have an influence on the save 

operation. All intended changes must be authorized by the manufacturer. 

Summary of Contents for WL 5000

Page 1: ...WL 5000 Specification and User Manual...

Page 2: ...e without notice Laird assumes no responsibility and disclaims all liability for losses or damages resulting from use of or reliance on this information All Laird products are sold subject to the Lair...

Page 3: ......

Page 4: ...ct Description 13 4 1 Description 13 4 2 Non Conformity with the Intended Use 13 4 3 Technical data 14 4 3 1 Physical dimensions 14 4 3 2 Performance data 14 4 3 3 Environmental specifications 14 4 3...

Page 5: ...5 8 Removal for Service 21 9 Wear Parts and Spare Parts 22...

Page 6: ...sion History Date Index Reason for Change Name Page 13 Apr 20 1 0 First version 22 May 20 2 0 New template Page no Updated A Olsson 10 MAR 2021 2 1 Corrected P N A Kim 06 OCT 2021 2 2 New template A C...

Page 7: ...uthorized Use of the product despite of defect wrongly implemented or non functional safety devices or protective gear Unauthorized or forbidden modifications by the user concerning the electrical equ...

Page 8: ...e use the contact information given below Always communicate the following Your name and address Name of contact at your address Product data as on identification plate Type of unit serial number and...

Page 9: ...roperty 2 2 Safety Symbols In this Operation Manual concrete safety instructions are given in order to point out unpreventable residual risks when operating the unit These risks include danger for Hum...

Page 10: ...concerning the unit should be reported to the responsible person Stick to accident prevention regulations as well as any regional regulations 2 3 2 Hints Regarding the Electrical Equipment DANGER Dan...

Page 11: ...ntally conscious behavior Environmentally hazardous substances must not get into the soil or into the drains They should be kept in appropriate containers Environmentally hazardous substances must be...

Page 12: ...ety equipment must be accessible at all times 2 4 1 Guards Direct access to hazardous parts or areas of the unit is restricted by the unit cover The cover may only be removed for maintenance or repair...

Page 13: ...n not be granted When using the unit in a way not compliant with the intended use hazardous situations may occur Operation of the unit is not permitted under the following conditions The unit is used...

Page 14: ...V 10 50 60 Hz Current consumption 2 6 A Noise level 63 dB A 50 Hz 67 dB A 60 Hz at 1 m distance in any direction Table 2 Performance data 3 3 3 Environmental specifications Operating temperature 10 C...

Page 15: ...d corrosion damage may result and are not covered by manufacturer s liability The unit is only authorized for use in indoor environments The unit must not be stored or operated in aggressive humid env...

Page 16: ...ons on page 9 4 2 Setting to Work 4 2 1 Connecting the unit electrically DANGER Electrical danger Work on electrical installations may be carried out by trained and authorized electricians only Switch...

Page 17: ...hoses Open lid Fill cooling unit with water about 5 0 l CAUTION The water level must be always above fins otherwise reduced cooling capacity Let the cooling unit run for about 10 minutes to deaerate t...

Page 18: ...available direct the air against the inside of the heat exchanger 4 Mount cover 5 2 Pump About every 3 months check the filter of the pump for clean condition in case of polluted water more often CAUT...

Page 19: ...r abrasive cleaning agents corrosion may occur as result of a damaged paint film For cleaning the device casing only use mild cleaning agents e g dish washing detergents Use clean and lint free cloth...

Page 20: ...20 6 Repair PLEASE NOTE Do not carry out any repair work on the unit Send the unit back to the LAIRD service department for contact see page 7...

Page 21: ...ore starting any service work disconnect the cooling unit from the mains Remove electrical connections Remove hoses Remove cap of the drain hole and purge coolant collect with suitable vessel Mount it...

Page 22: ...e of damages caused by the use of spare parts made by manufacturers other than LAIRD PLEASE NOTE Identification data concerning the unit and spare parts The type of unit and the article number can be...

Page 23: ...3 O Ring for cap Not available 4 Thermal switch 2032 00 5 Lid 2075 00 6 Motor with coupling 2001 00 7 Flexible coupling 2038 00 8 Fan 2029 00 9 Capacitor for fan 2088 00 10 Filter 2081 00 11 Flow swit...

Reviews: