3.4.4 Optical Isolated Input Port 1
Electrical Characteristics
Control Logic
Minimum input
Maximum input
Voltage(V) Amperage(mA) Voltage(V) Amperage(mA)
Logical High
2.9
1
16
7
Logical Low
0
0
0.8
0.3
3.4.5 Analog Input Port
This analog input port can be used to measure the input signal’s voltage level. Input
signal’s voltage range is 0 to 3.3V.
3.4.6 RS232 Port
The Starfinder-Aire can communicate with other devices using the RS232 port.