WRIST BLOOD PRESSURE MONITOR

  Do not use any chemical or abrasive products to clean the monitor.

  Ensure that no liquids enter the appliance.

• 

This appliance is not waterproof.

•  Place the device in the supplied case and, to store it, observe the environmental conditions stated 

here below. 

SPECIAL CASES

If the following circumstances occur:

1)  After pressing the 0/I key the reading does not start.

•  Check the batteries and replace them if needed.

•  Clean the contacts of the batteries with a dry cloth.

2)  Nothing appears on the display when the M key is pressed.

•  The batteries are flat.

3)  The batteries do not last long.

•  use alkaline batteries to increase working autonomy. If normal zinc-carbon batteries are used 

they will need changing more often.

4)  You cannot complete a reading.

•  check the batteries and change them if needed.

5)  The blood pressure levels are different with each reading - the readings are very low or very high.

•  the measuring position is not correct - Read the paragraph “Correct measuring position” again.

•  the blood pressure readings vary constantly depending on the time of day and the state of 

nerves of the person. Read the paragraphs “Warnings” and “Important” again.

6)  The heart beat readings are too high or too low:

•  The person moved while the reading was being taken.

•  The reading was taken after physical exertion. Read the paraghaphs “CORRECT MEASURING 

METHOD”, “WARNINGS” and “IMPORTANT” again.

7)  On the display, appears the symbol

.

•  It has been detected the presence of an irregular pulse (arrhythmias). Repeat the measurement.

 

If the symbol

 appears again, refer to a physician to establish the most 

suitable treatment to be followed

COMPONENTS

1)    LCD DISPLAY

2)    0/I KEY

3)    M KEY

4) ARMBAND

5)  BATTERY COMPARTMENT

6)   BATTERIES

7) CASE

TECHNICAL FEATURES

•  Pressure indication range: 

between 0 and 300 mmHg (arm cuff pressure)

   

between 40 and 180 pulsations/min. (pulse frequency)

•  Precision: 

±3 mmHg (arm cuff pressure)

   

± 5% of the read value (pulse frequency)

•  Inflating and deflating:  

automatic

•  Power supply:  

2 alkaline batteries type AAA (LR03)

•  Memories:  

60 Memories

•  Working conditions:  

b5°C and +40°C; 90% relative humidity or lower

•  Storage conditions:  

between -20°C and +55°C; 90% relative humidity or lower

•  Atmospheric Pressure:  

80kPa – 105 kPa

•  Wrist circumference: 

between 140 and 195 mm approx.

•  Battery life:  

about 180 readings

•  Dimensions:  

86x68x32 mm

•  Weight:  

about 130 g (without alkaline batteries)

Important! Read the instructions carefully

Type BF apparatus

Summary of Contents for BM1001

Page 1: ...DOR DE PRESIÓN DE PULSO Instruções e garantia MEDIDOR DE TENÇÃO DE PULSO Anleitungen und Garantie HANDGELENK BLUTDRUCKMESSGERÄT ËÁ Â Î È ÂÁÁ ËÛË π ª ƒ ƒ À Instrucţiuni şi garanţie TENSIOMETRU PENTRU ÎNCHEIETURA MÂINII Instructies en garantie POLSDRUKMETER MISURATORE DI PRESSIONE DA POLSO ISTRUZIONI E GARANZIA FR GB ES PT DE EL RO NL BM1001 ...

Page 2: ... 2 TASTO O I 3 TASTO M 4 BRACCIALE 5 COPERCHIO BATTERIE 6 BATTERIE 7 CUSTODIA COMPONENTS 1 LCD DISPLAY 2 0 I KEY 3 M KEY 4 ARMBAND 5 BATTERY COMPARTMENT 6 BATTERIES 7 CASE MISURATORE DI PRESSIONE DA POLSO BM1001 1 4 5 2 3 6 7 ...

Page 3: ...re di battiti irregolari Indicator of irregular pulse Mese Month Giorno Day Sistolica Sistolic Diastolica Diastolic Pulsazioni Heart beat Numero di memorie Memory number Segmenti di riferimento per la classificazione dei valori della pressione sanguigna Reference segments for the classification of the blood pressure values ...

Page 4: ...FIG 4 FIG 5 FIG 6 FIG 7 POSIZIONE CORRETTA DI MISURAZIONE PERFORMING A MEASUREMENT MISURATORE DI PRESSIONE DA POLSO ...

Page 5: ...ecific physical or psychical condition temporary noise or of a real and proper heart disease Always refer to a physician in case the blood pressure monitor shows the symbol for irregular heart rate in order to establish the most suitable treatment to be followed Accurate and easy to use this device enables even the elderly and less expert to measure blood pressure in the comfort of their own home ...

Page 6: ... Any other use shall be considered improper and hence hazardous The manufacturer cannot be held responsible for any damage resulting from improper or incorrect use WARNING 1 If there is reduced blood circulation in the arm due to acute or chronic vascular diseases including the restriction of the diameter of the blood vessels the precision of the measurement could be affected 2 In the case of card...

Page 7: ... range 130 139 85 89 refer to a physician High blood pressure 1st level 140 159 90 99 refer to a physician High blood pressure 2nd level 160 179 100 109 refer to a physician High blood pressure 3rd level beyond 180 beyond 110 refer to a physician At the end of each measurement the measured pressure data are compared with the above mentioned table The segments appearing on the left of the display i...

Page 8: ...se the case or a similar object to support the forearm 6 Place both feet on the ground 7 Remember that the blood pressure changes during the day Try to effect more measurements during the day for better understanding the reactions of your body to the different moments of your day after a physical activity during the job after the meals 8 Do not take only one measurement At least two measurements s...

Page 9: ...trument is not going to be used for a long time 4 Remove run down batteries by sliding the cover of the batteries compartment following the arrow direction Extract the batteries and dispose them as special waste at the specific collection points forecast for recycling For more information about the disposal of run down batteries please contact either the store where the device containing the batte...

Page 10: ...o fastening 3 The wrist cuff must be snug around your wrist but not too tight PERFORMING A MEASUREMENT 1 After having positioned the device on the right or left wrist press the key O I When the device is ON the key O I lights The device emits a long acoustic signal and on the display only for few seconds all function symbols do light 2 Should any previous measurements have been stored the display ...

Page 11: ...e pump which then cannot provide enough pressure in the preset time interval For this reason ERR will appear Replace the batteries MEMORY FUNCTION This device can store up to 60 measurements After each measurement the following values are stored automatically diastolic systolic pulse date and time memory number reference segments for the classification of the blood pressure values see paragraph CL...

Page 12: ...TORS The following symbols may appear on the display EE no measurement could be taken as the arm moved incorrect position other see section entitled CORRECT MEASURING METHOD batteries finished Replace batteries Pulse frequency symbol M progressive memory number assigned to each measurement indicator of irregular pulse reference segments for the classification of the blood pressure values CARE AND ...

Page 13: ...eries are used they will need changing more often 4 You cannot complete a reading check the batteries and change them if needed 5 The blood pressure levels are different with each reading the readings are very low or very high the measuring position is not correct Read the paragraph Correct measuring position again the blood pressure readings vary constantly depending on the time of day and the st...

Page 14: ...ressure 5 of the read value pulse frequency Inflating and deflating automatic Power supply 2 alkaline batteries type AAA LR03 Memories 60 Memories Working conditions between 5 C and 40 C 90 relative humidity or lower Storage conditions between 20 C and 55 C 90 relative humidity or lower Atmospheric Pressure 80kPa 105 kPa Wrist circumference between 140 and 195 mm approx Battery life about 180 read...

Page 15: ...lectromagnetic emissions at the end of these instructions DISPOSAL PROCEDURE Dir 2012 19 Eu WEEE The symbol on the bottom of the device indicates the separated collection of electric and electronic equipment At the end of life of the device do not dispose it as mixed solid municipal waste but dispose it referring to a specific collection centre located in your area or returning it to the distribut...

Page 16: ...ed Warranty decays after 2 years from the purchase date In this case technical service interventions will be carried out against payment Information on technical service interventions under warranty terms or against payment may be requested by writing at info laica com Repair or replacement of products covered by the warranty terms are free of charge In case of faults refer to the dealer DO NOT se...