13
Adjusting Table Gibs
Adjust gibs (D, Figure 22) by loosening the
hex nuts (E, Figure 22), and turning gib
screws (F, Figure 22) so that the ways
(G, Figure 22) are lightly contacted.
You should be able to get a 0.005” feeler
gauge in between the gib and way.
Adjusting Table Rollers
The table rollers come pre-set from the
factory and shouldn’t need any adjustment.
If you find adjustment is necessary, follow
the below listed steps.
1. Lay a straight edge (A, Figure 23) on
the table across the roller (B, Figure 23).
2. Raise the rollers until it contacts the
straight edge and lock the handle. The
pointer should be set at “0”. If not
adjust the pointer to read zero. Note:
Spin the roller by hand to know when
roller makes contact with the straight
edge.
3. Move straight edge to the opposite side
of bed roller and check to see that the
roller just contacts straight edge. If not
loosen the hex nut (C, Figure 24) and
turn the hex cap bolt (D, Figure 24) to
raise or lower the bed roller until it just
contacts the straight edge.