LOCK OPERATING CONVENTIONS
• If a mistake is made while entering keystrokes, wait thirty (30)
seconds and repeat operation.
• To access lock commands, enter combination and hold down the
last digit until Lock double signals release and the LED stays on.
• In Dual Mode, two combinations are required to operate
the Lock.
NOTE: In Dual Mode, just the Manager combination needs to
be entered to access the following Manager Commands: 1, 2,
3, 7 and 9.
• Lock must be opened within 4 seconds once a valid combination
has been entered.
• To open a container with a Swing Bolt Lock, turn the container
handle to the open position and open the door.
• To open a container with a Dead or Spring Bolt Lock, turn the
keypad or dial to retract the bolt and open the door.
• When closing a container, verify that it has been secured.
LOCK RESPONSES
Standard Operations
Entry Devices with LEDs (3125, 3190 and 3750-K) respond with
both LED flashes and beeps.
• Single signal - one (1) LED flash and one (1) beep indicate the
operation is complete.
• Double signal - two (2) LED flashes and two (2) beeps indicate
entry is valid or accepted.
• Triple signal - three (3) LED flashes and three (3) beeps indicate
invalid or not accepted.
NOTE: The 8130 Entry Device (no LED) responds with beeps only.
Additional Operations
• Delay Period - The LED will flash once every second.
• Open Period - The LED will flash twice a second, and the Entry
Device will beep every 10 seconds.
• If any key is pressed, the Lock will flash the LED and beep
three times.
• Penalty Period - The LED will flash every ten (10) seconds.
• Low Battery Warning - During a Lock opening, the LED will flash
and Entry Device will beep repeatedly.
SUPER MASTER RESET
SMR will reset the lock back to factory state, but the SM code
remains unchanged. The default code of 5-5-5-5-5-5-5-5 must be
changed before the Manager default code is changed or the Super
Master Reset function will be permanently lost.
Process is as follows:
• Action - Press and hold [0] key for 3 seconds
• Result – Lock beeps twice and the LED remains ON throughout
the entire process.
• Action – Enter default code of 5-5-5-5-5-5-5-5. Press and hold
last digit until the unit gives a double beep.
• Result – Command Menu access is granted.
SMR has only 2 Command options available:
• If press [0] =
Change Code, (1 time use)
• Enter current default Super Master code of 5-5-5-5-5-5-5-5
• Enter new Super Master code (ex. 8-8-8-8-8-8-8-8) then
double beep.
• Enter new Super Master code again to confirm (ex. 8-8-8-8-8-8-
8-8) then double beep the SMR code is set.
NOTE: Once the default code is changed to a new code the code
can never be changed. A reset box must be used to reset.
• If press [8] =
Reset the Lock
• Lock will signal a long beep to indicate it was reset
• If any other key is pressed then the lock beeps 3 times and the
operation is ended.
MANAGER COMMANDS
COMMAND 1
Activate User
NOTE: Only Users added during Lock Setup will be available to the
Manager for activation.
1. Enter Manager combination and
hold down last digit of
combination until Lock double signals release and the LED
stays on.
2.
PRESS 1.
3. Enter User number (1- 9).
4. Enter the NEW User combination.
5. Re-enter the NEW User combination to confirm.
User combination is now active.
Reinstate User
1. Enter Manager combination and
hold down last digit of
combination until Lock double signals release and the LED
stays on.
2.
PRESS 1.
3. Enter User number (1- 9).
User is reinstated.
COMMAND 2
Disable User
1. Enter Manager combination and
hold down last digit of
combination until Lock double signals release and the LED
stays on.
2.
PRESS 2.
3. Enter User number (1- 9).
User is temporarily disabled. The User combination is saved and
will be valid once reinstated.
COMMAND 3
Delete User
1. Enter Manager combination and
hold down last digit of
combination until Lock double signals release and the LED
stays on.
2.
PRESS 3.
3. Enter User number (1- 9).
User is deleted.
COMMAND 7
Audit Lock (ComboGard Pro auditing software, AuditView or
LgView3X, and a LA GARD Interface Adapter are required)
To audit the Lock using ComboGard Pro AuditView Software, you
can also refer to
ComboGard Pro AuditView User Instructions
(786.0310).
Start the Auditing Software Program:
1. Plug the USB or Serial Interface Adapter into an available port on
the PC.
2. Plug the appropriate audit cable for the Entry Device into the
USB or Serial Interface Adapter.
3. Start auditing software program.
4. From the auditing software, select the
Configuration menu on
the Menu bar.
5. Select the appropriate COM port from the list