LOCK OPERATING CONVENTIONS 

•  If a mistake is made while entering keystrokes, wait thirty (30) 
  seconds and repeat operation. 
•  To access lock commands, enter combination and hold down the
  last digit until Lock double signals release and the LED stays on.
•  In Dual Mode, two combinations are required to operate 
  the Lock. 

NOTE: In Dual Mode, just the Manager combination needs to 
be entered to access the following Manager Commands: 1, 2, 
3, 7 and 9.

•  Lock must be opened within 4 seconds once a valid combination
  has been entered.
•  To open a container with a Swing Bolt Lock, turn the container 
  handle to the open position and open the door.
•  To open a container with a Dead or Spring Bolt Lock, turn the 
  keypad or dial to retract the bolt and open the door. 
•  When closing a container, verify that it has been secured.

LOCK RESPONSES 

Standard Operations
Entry Devices with LEDs (3125, 3190 and 3750-K) respond with 
both LED flashes and beeps. 
•  Single signal - one (1) LED flash and one (1) beep indicate the 
  operation is complete. 
•  Double signal - two (2) LED flashes and two (2) beeps indicate 
  entry is valid or accepted. 
•  Triple signal - three (3) LED flashes and three (3) beeps indicate 
  invalid or not accepted. 
NOTE: The 8130 Entry Device (no LED) responds with beeps only. 

Additional Operations
•  Delay Period - The LED will flash once every second.  
•  Open Period - The LED will flash twice a second, and the Entry 
  Device will beep every 10 seconds.  
•  If any key is pressed, the Lock will flash the LED and beep 
  three times.
•  Penalty Period - The LED will flash every ten (10) seconds.  
•  Low Battery Warning - During a Lock opening, the LED will flash 
  and Entry Device will beep repeatedly.  

SUPER MASTER RESET 
SMR will reset the lock back to factory state, but the SM code 
remains unchanged. The default code of 5-5-5-5-5-5-5-5 must be 
changed before the Manager default code is changed or the Super 
Master Reset function will be permanently lost.

Process is as follows:
•  Action - Press and hold [0] key for 3 seconds
•  Result – Lock beeps twice and the LED remains ON throughout 
  the entire process.
•  Action – Enter default code of 5-5-5-5-5-5-5-5. Press and hold 
  last digit until the unit gives a double beep.
•  Result – Command Menu access is granted.

SMR has only 2 Command options available:
•  If press [0] = 

Change Code, (1 time use)

•  Enter current default Super Master code of 5-5-5-5-5-5-5-5
•  Enter new Super Master code (ex. 8-8-8-8-8-8-8-8) then 
  double beep.
•  Enter new Super Master code again to confirm (ex. 8-8-8-8-8-8-
  8-8) then double beep the SMR code is set.
NOTE: Once the default code is changed to a new code the code 
can never be changed. A reset box must be used to reset.

•  If press [8] = 

Reset the Lock

•  Lock will signal a long beep to indicate it was reset
•  If any other key is pressed then the lock beeps 3 times and the 
  operation is ended.

MANAGER COMMANDS

COMMAND 1
Activate User 
NOTE: 
Only Users added during Lock Setup will be available to the 
Manager for activation. 

1. Enter Manager combination and 

hold down last digit of 

  combination until Lock double signals release and the LED 
  stays on

2. 

PRESS 1

3. Enter User number (1- 9). 
4. Enter the NEW User combination.
5. Re-enter the NEW User combination to confirm. 
  User combination is now active. 

Reinstate User 
1. Enter Manager combination and 

hold down last digit of 

  combination until Lock double signals release and the LED 
  stays on

 2. 

PRESS 1

3. Enter User number (1- 9). 
  User is reinstated. 

COMMAND 2
Disable User  
1. Enter Manager combination and 

hold down last digit of 

  combination until Lock double signals release and the LED 
  stays on

2. 

PRESS 2

3. Enter User number (1- 9). 
  User is temporarily disabled. The User combination is saved and 
  will be valid once reinstated.

COMMAND 3
Delete User  
1. Enter Manager combination and 

hold down last digit of 

  combination until Lock double signals release and the LED 
  stays on

2. 

PRESS 3

3. Enter User number (1- 9). 
  User is deleted. 

COMMAND 7
Audit Lock
 (ComboGard Pro auditing software, AuditView or 
LgView3X, and a LA GARD Interface Adapter are required)
 
To audit the Lock using ComboGard Pro AuditView Software, you 
can also refer to 

ComboGard Pro AuditView User Instructions 

(786.0310)

Start the Auditing Software Program:
1. Plug the USB or Serial Interface Adapter into an available port on
  the PC. 
2. Plug the appropriate audit cable for the Entry Device into the 
  USB or Serial Interface Adapter. 
3. Start auditing software program. 
4. From the auditing software, select the 

Configuration menu on 

  the Menu bar. 
5. Select the appropriate COM port from the list 