![Lafferty 950735 Installation & Operation Instructions Download Page 4](http://html1.mh-extra.com/html/lafferty/950735/950735_installation-and-operation-instructions_3283470004.webp)
Troubleshooting Guide
Problem
Possible Cause / Solution
Startup
Maintenance
A) Fogger will not draw chemical or is sputtering
B) Fog is too wet
C) Air compressor will not turn on.
1, 2, 3, 4
1, 4
6, 7, 8
5
9
Possible Cause / Solution
Startup
Maintenance
1. Air line too small, not enough air pressure or volume
See REQUIREMENTS, page 1.
2. Air pressure too high.
Slightly close the air supply valve to lower the pressure
by lowering the volume until the fogger smooths out.
The air compressor default factory setting is 90 PSI,
which can be adjusted using the compressor regulator.
3. Chemical tube kinked or not immersed in chemical or
chemical depleted.
Straighten tube / replenish chemical
4. Drawing too much solution
Install optional metering tip
5. Pin hole or cut in suction tube
Replace suction tube.
6. Chemical tube clogged up
Clean or replace
7. Metering tip or metering tip holder clogged
Clean or replace metering tip and/or metering tip holder.
8. Debris clogging the fogger inlet jets
Disconnect air supply, remove fogger bodies and
visually inspect; remove debris from fogger inlet.
9. Problem with air compressor
Refer to air compressor instruction manual.
Press the reset button. See manual.
PREVENTIVE MAINTENANCE: When the unit will be out of service for extended periods, place chemical tube(s) in water and flush the chemical out
of the unit to help prevent chemical from drying out and causing build-up. Periodically check and clean chemical strainer and replace if missing.
950735 • Compact Precision Fogger With Compressor Kit
January 30th 2021