Lafayette Instrument 63040A User Manual Download Page 6

3700 Sagamore Parkway North . PO Box 5729 . Lafayette, IN 47903 USA . Ph: 765-423-1505         

ELECTRONIC VOICE REACTION TIMER

6

6

6.

7.

8.

1.

2.

Regardless of which relay is chosen to be adjusted, the next screen to appear on the LCD is
the following;

                    DELAY  =  0.500S
                    INC     DEC     OK

The delay period can now be incremented in 10 millisecond steps by pressing the 

INC

 button.

The maximum delay is 2.000 seconds. Conversely, the delay period can be decremented in 10
millisecond steps by pressing the 

DEC

 button.  The minimum delay is 0.000 seconds.  When

the delay is set to the desired period, pressing the 

OK

 button will bring the user back to the

previous screen, where the other relay may be selected for adjustment or the 

OK

 button can be

pressed and testing may begin. When the 

INC

 or 

DEC

 button is pressed and held, the delay

value will change at a moderate rate for the first five values and then change at a much faster
rate until the button is released.

In this mode of operation Relay 3 is not used.

Pressing the Quit button will cause the unit to exit this mode and return to the main
configuration selection screen.

Non-latching/Non-sequential Mode

When in this mode of operation any trigger input from either microphone will cause it's
corresponding relay to close for the time determined by the delay period.

The same testing screen as for the Non-latching/Sequential Mode is displayed and the
selection menu responds in the same manner.

Summary of Contents for 63040A

Page 1: ...3700 Sagamore Parkway North P O Box 5729 Lafayette IN 47903 USA Tel 765 423 1505 800 428 7545 Fax 765 423 4111 E mail info lafayetteinstrument com www lafayetteinstrument com Model 63040A ELECTRONIC...

Page 2: ...hone or a manual pushbutton all of which are supplied with each unit A microprocessor is employed to provide overall control of the unit s functions It operates in four different modes which are Latch...

Page 3: ...ds selectable in 10 millisecond increments This is further described in Non latching Sequential Mode instruction 6 pg 5 Once the type of latching mode is determined the next message to be displayed wi...

Page 4: ...the sensitivity setting for that microphone is at the desired value pressing the OK button will bring you back to the PICK MICROPHONE screen Pressing the OK button will take the user back to the prev...

Page 5: ...ting can immediately begin Since this is a sequential mode of operation microphone 1 must produce a trigger input before microphone 2 s input will become valid If microphone 1 has produced a trigger a...

Page 6: ...k to the previous screen where the other relay may be selected for adjustment or the OK button can be pressed and testing may begin When the INC or DEC button is pressed and held the delay value will...

Page 7: ...mail info lafayetteinstrument com Model 63040A User s Manual 7 7 System Specifications Power Supply 12VDC Power Consumption 0 75W Frequency Response 50 7000Hz 10mVRMS Sensitivity 4 0mV Output 3 sets...

Page 8: ...d along with a cover letter explaining the malfunction Please also state the name of the Lafayette Instrument representative authorizing the return An estimate of repair will be given prior to complet...