background image

Laerdal Suction Unit

 

BEMIS Disposable Canister

User Guide

EN

www.laerdal.com

Cat. 

No. 

78002001

Summary of Contents for Suction Unit

Page 1: ...Laerdal Suction Unit BEMIS Disposable Canister User Guide EN www laerdal com Cat No 78002001 ...

Page 2: ... of 4 hours to reach full battery capacity The fast charging gives approx 80 battery capacity after 3 hours for a new battery Please note that repetitive 3 hour charging is not recommended If it is not possible to place the LSU on continuous charge when not in use make sure the battery is charged for a minimum of 4 hours at least once a month If LSU battery is kept on constant charge perform devic...

Page 3: ...Interface 7 3 3 Canister 12 3 4 Power Sources Connector Sockets 13 3 5 Automatic Power save Function 13 4 Operation 14 4 1 Getting Started 14 4 2 Replace the Canister 15 4 3 After Use 16 5 Maintenance 16 5 1 General 16 5 2 Battery 16 5 3 Clean the Cabinet 16 5 4 Charge the Battery 17 5 5 Check the Battery Quality 17 5 6 Replace the Battery 18 6 Servicing 18 7 Troubleshooting 19 8 Parts List 20 9 S...

Page 4: ...eatures and Benefits Splash proof rugged and solid Easy access to the tubing Equipped with an internal battery that can easily be replaced without using tools Charging of battery can be done directly from AC or DC mains no external charger is needed Fast charge of 3 hours giving approx 80 battery capacity Operation possible from internal battery and directly from AC or DC mains no adapter is neede...

Page 5: ...ms and battery 2 5 Unpacking Remove the LSU from its packaging and inspect all parts for damage If there are any signs of damage or if any parts are missing imme diately notify Laerdal or one of its authorized dealers Insert the battery according to section 5 6 Place the LSU on charge for a minimum of 4 hours to make sure you have a fully charged battery see section 5 4 Perform the Device Test acc...

Page 6: ...6 3 Description LSU Vacuum Connector Patient Suction Tubing Canister Holder Battery Door Canister Holder Release Arm Canister Canister Lid w Bacterial Filter Shut Off Valve Strap for Patient Suction Tubing Vacuum Connector Tubing Vacuum Port Patient Port ...

Page 7: ...d setting Each setting indicates the maximum achievable vacuum level for the selected position 80 120 200 350 500 mmHg The free air flow value changes along with the increasing vacuum settings see section 9 4 for details The LSU is switched OFF by resetting the Operating Knob to 0 7 TEST Button Power ON Indicator Vacuum Indicator Battery Status Indicator Operating Knob External Power Indicator Fai...

Page 8: ...he Indicator continues to be lit after three OFF ON cycles and after replacing the battery with a fully charged battery discontinue use and contact a Laerdal Service Center See section 6 Failure Mode Indication caused by external electrical interference may occur on any digital equipment including the LSU Such fault will usually not be repeated 3 2 2 4 Vacuum Indicator This green LED bar graph dis...

Page 9: ... lit 20 1 LED lit Battery Low min 1 minute of operation left based on 500 mmHg free flow 1 LED flashes Note If the LSU or the NiMH battery has been stored at low temperatures 12 C 54 F the LSU may indicate lower remaining battery capacity than actual when first switched on This is due to the nature of NiMH batteries The battery indicator may flash on one LED which normally indicates Battery Low Th...

Page 10: ...tton make sure the Patient Suction Tubing is not occluded or bent DEVICE TEST DESCRIPTION Press and hold the TEST Button while setting the Operating Knob to 500 mmHg Note Do not release the TEST Button until min 2 seconds after the Operating Knob has been set to 500 mmHg The test will start immediately As soon as LED 2 of the Battery Status Indicator comes on takes approx one second fully occlude ...

Page 11: ...ction 6 TEST STEP DISPLAYED ON THE BATTERY STATUS INDICATOR STEP 1 Occlusions STEP 2 Vacuum Build Up Efficacy within 3 seconds STEP 3 Max Achievable Vacuum within 10 seconds STEP 4 Air Leakage TEST RESULT DISPLAYED ON THE VACUUM INDICATOR Test Passed 100 mmHg Test Passed 300 mmHg Test Passed 500 mmHg Test Passed 450 mmHg ACTION IF TEST FAILED Check possible occlusions e g twisted tubing and run th...

Page 12: ... a Shut Off Valve that shuts off the vacuum if the Canister is full or the LSU tips over To reset the valve remove the Vacuum Connector Tubing from the LSU Note All parts are Single Use and must be replaced after each use 12 Vacuum Connector Tubing LSU Vacuum Blue Angled Connector Disposable Canister Vacuum Port Patient Port Angled Connector Patient Port Bacterial Filter Patient Suction Tubing Can...

Page 13: ...ion and charging is available separately see section 8 External power connection will cause the External Power Indicator to be lit 3 5 Automatic Power save Function The LSU has an Automatic Power save Function that switches OFF the pump motor While in this mode the Power ON Indicator will flash slowly approx once per second This function will be activated when the Operating Knob is set to 200 350 ...

Page 14: ...ubing is securely connected to the Patient Port on the Canister Lid 4 Check that a suction catheter is attached to the patient suction tube or suction adapter Do not use the suction tube or suction adapter without a suction catheter attached Proceed as follows 5 Release the Patient Suction Tubing by releasing the Strap 6 The LSU should be operated in the upright position to prevent overflow of suc...

Page 15: ...oceed as follows 1 Disconnect the Angled Connector from the Vacuum Port on the Lid Connect the suction end of the Patient Suction Tubing to the Vacuum Port to avoid spillage 2 To release the Canister Holder press down the Canister Holder Release Arm while sliding the Holder towards you Remove the Canister from the Holder 3 Safely dispose of the contents of the Canister according to local protocols...

Page 16: ...hen it does not pass the Battery Quality Check see section 5 5 for details or after 3 years Do not store the LSU with an discharged battery 5 3 Clean the Cabinet Warning Disconnect the LSU from external power prior to cleaning Use a minimum of liquid to prevent any electrical shock hazard Do not immerse the LSU or allow it to stand in water or other liquids This can damage the device and cause ele...

Page 17: ...ter use It is recommended to always fully charge the battery Repetitive charging to a lower capacity level will reduce battery life If it is not possible to place the LSU on continuous charge when not in use make sure the battery is charged for a minimum of 4 hours at least once a month Do not store the battery when it is discharged Always fully charge the battery before storage The recommended am...

Page 18: ...ed There are no user serviceable parts inside the cabinet Do not open the cabinet Refer servicing to a Laerdal Service Center or Laerdal authorized LSU servicer Contaminated suction units will not be serviced by Laerdal Medical If you are discarding the battery dispose of safely according to local protocols 18 6 Servicing 1 Open the Battery Door 2 To remove the battery push and move it slightly to...

Page 19: ...n Pump Unit and Canister Patient Suction Tubing twisted or blocked Battery is not charged Tube s is kinked or twisted ACTION Check power cord connec tions and the external AC or DC power source The LSU must be returned for service see section 6 Check that battery is installed Place the LSU on charge If still faulty after charging com pleted remove and replace the battery see section 5 6 Unplug the...

Page 20: ...g 78 26 00 Wall Bracket w DC Power Cord not illustrated 78 26 10 Wall Bracket w AC Power Cord US not illustrated 78 26 40 Wall Bracket w o Power Cord not illustrated 78 23 00 Shoulder Strap 78 24 00 01 Side Pouch 78 04 40 External charger kit not illustrated Parts 78 04 20 Bemis Canister Holder 78 04 33 Strap for Tubing 78 04 32 Release Arm 78 02 00 DC Power Cord 78 02 10 AC Power Cord US 78 08 00...

Page 21: ...uipment If adjacent or stacked use is necessary the MEDICAL ELECTRICAL EQUIPMENT should be observed to verify normal operation in the configuration in which it will be used 9 2 General tolerance Overall tolerance 5 9 3 Physical Characteristics Size 315 mm 12 4 in x 330 mm 13 in x 160 mm 6 3 in h x w x d Weight 3 7 Kg 8 2 lbs including NiMH battery Canister Shipped with BEMIS HI FLOW Suction Canist...

Page 22: ... Charging Temperature 15 C 59 F to 25 C 77 F Long Term Storage Temperature 0 C 32 F to 40 C 104 F Max 24 hour Storage Temperature 30 C 22 F to 70 C 158 F The time required for the LSU to warm from the mini mum storage temperature between uses until it is ready for intended use is min 90 minutes at room temperature The time required for the LSU to cool from the maxi mum storage temperature between ...

Page 23: ...duct is in compliance with the essential requirements of MDD 93 42 EEC as amended by Council directive 2007 47 EC and Council directive 2011 65 EU relating to restriction on the use of certain Hazardous Substances RoHS 2 Do not reuse Date of production Warning Caution Consult User Guide The products is eligible to bear the CSA Mark with adjacent indicators C and US for Canada and US This appliance...

Page 24: ...nt adjacent to or stacked with other equipment should be avoide because it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally Warning Use of accessories transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagn...

Page 25: ...z 28 V m 1700 1990 MHz 28 V m 2400 2470 MHz 28 V m 5100 5800 MHz 9 V m Rated power frequency magnetic fields IEC 61000 4 8 30 A m 50 Hz or 60 Hz Electrical fast transients bursts AC power port IEC 61000 4 4 2 kV 100 kHz repetition frequency Surges Line to line AC power port IEC 61000 4 5 0 5 kV 1 kV Conducted disturbances induced by RF fields AC power port IEC 61000 4 6 3 V 0 15 MHz 80 MHz 6 V in ...

Page 26: ......

Page 27: ......

Page 28: ...x 377 Tanke Svilandsgate 30 4002 Stavanger Norway Tel 47 51 51 17 00 Fax 47 51 52 35 57 Distributed in USA by LAERDAL MEDICAL CORPORATION 167 Myers Corners Road Wappingers Falls NY 12590 8840 Tel 1 800 431 1055 1 845 297 7770 Fax 1 800 227 1143 Printed in Norway www laerdal com 6791 Rev J ...