background image

SimPad 

PLUS

User Guide

EN

www.laerdal.com

Summary of Contents for SimPad PLUS

Page 1: ...SimPad PLUS User Guide EN www laerdal com ...

Page 2: ...SimStore 42 Software 44 Vocal Sounds 45 Laerdal Li Ion Battery 47 Features 49 The SimPad PLUS System is an easy to use wireless tool that performs relevant medical simulation training including debriefing in various user settings With its large intuitive touch screen design SimPad PLUS is a Pick up and Play experience delivering simulation based education easily and efficiently There are two ways ...

Page 3: ...dio in Audio out USB Battery Connection Side Panel Connector Link Box PLUS Overview 5 SimPad PLUS Overview 4 Auxiliary button On Off Status LED Audio out USB Ethernet DC FrontView Back View Manikin Cable Battery Connection Blood PressureTube ...

Page 4: ...Pad PLUS Off but battery charged steady yellow light SimPad PLUS on steady green light Error needs service steady red light Contact your local Laerdal representative SimPad PLUS Setup SimPad PLUS Setup 6 7 Turn On SimPad PLUS When charged turn on by pressing On Off button LED starts flashing green A steady green LED indicates the device is ready to use ...

Page 5: ...green light Error needs service steady red light Contact your local Laerdal representative Batteries charged steady yellow light Link Box PLUS on steady green light 9 Link Box PLUS Setup Link Box PLUS Setup Release the button when the LED starts flashing green Turn on by pressing On Off button A steady green LED indicates the device is ready to use ...

Page 6: ...ns may be altered later SimPad PLUS Setup 11 Starting SimPad PLUS for the first time The first time SimPad PLUS is turned on follow the prompts to configure the device SimPad PLUS Setup 10 Select language Choose country pre select time zone Enter SimPad name Optional About SimPad Enter Link Box name optional Enter SimPad name optional About Simulator ...

Page 7: ...ected to a network steady green light Connected to a SimPad PLUS steady blue light Link Box PLUS Setup 13 SimPad PLUS Setup 12 Turn Off SimPad PLUS Turn off by pressing On Off button Tap to shutdown SimPad and or Simulator ...

Page 8: ...Pad PLUS communicates with the Link Box PLUS using WiFi If no other Link Boxes are visible on the default SimLink network the SimPad PLUS will automatically connect to the Link Box PLUS SimPad PLUS will remember the pairing and reconnect when the units are turned on again If multiple Link Boxes are available choose preferred Link Box PLUS A manikin symbol is indicated on SimPad when connected to t...

Page 9: ...atient status Categories of interventions Tap to add comment Tap to log interventions and events Last logged event Select Scenario Tap for detailed information on Scenario Scenarios Select from Scenario menu Tap START to enter Session information Tap OK when ready Add Instructor Add Participant ...

Page 10: ...d scenario Open current session log Display more or less information Using Automatic Mode Change Parameters Tap here to display more patient state information Access to vital signs adjustments Abnormal parameter values displayed here Select other parameters to adjust ...

Page 11: ...e Select other parameters to adjust Pause session Patient vital signs Abnormal values Collapse mini log End session Register participant s interventions White arrow indicates last activated state Flag indicates start state Tap to show detailed State information before activating Tap to open state Time since Session started The expanded state shows all parameters in the queue ready to be activated ...

Page 12: ...just parameters Using Manual Mode 23 Using Manual Mode 22 Registering Interventions Time since scenario was started Patient status Tap to log interventions and events Last logged event Categories of interventions Tap to add comment Tap to register participant s interventions Select a parameter from the menu Tap to set desired condition Update the currently open state ...

Page 13: ...te for an ExistingTheme Tap to access Circulation Menu Select your desired parameter Tap to create a new state New state visible 1 Tap to add new state to theme 4 Tap to save state to theme New state is now ready Tap and hold to arrange states Tap x to delete 3 Confirm 2 Enter new state name ...

Page 14: ...ch Tap time display to activate the Stopwatch View log Note Technical logs can be retrieved from Link Box PLUS for troubleshooting purposes Go to LogViewer Resume session Tap to select new session Back to home screen Toggle On Off to view detailed log ...

Page 15: ... mode provides an additional log file with data from CPR training Manual Mode Tap to enlarge QCPR feedback Automatic Mode Tap to enlarge QCPR feedback Full Session with compressions and ventilations over time Compression depth Chest release Compression rate Ventilation volume Indicates two main findings from the CPR performance Tap to access log ...

Page 16: ...QCPR QCPR 30 31 QCPR Summary Compression Analysis OverTime CPR settings can be adjusted to individual needs Laerdal recommends using settings compliant with ILCOR guidelines ...

Page 17: ...nnecting the SimPad PLUS Patient Monitor to the SimPad PLUS System available at www laerdal com downloads Using a direct network cable to connect the Link Box to the simulated Patient Monitor is recommended to minimize WiFi traffic QCPR Simulated Patient Monitor 32 33 Toggle between displays Display Choices With overall score Without overall score Select the appropriate Simulator from the connecti...

Page 18: ...tomatically updated if necessary From SimPad PLUS Home Screen go to System Settings About simulator Force update simulator firmware SessionViewer SessionViewer is a free software solution that enables instructors or students to view debriefing from the SimPad PLUS System Use SessionViewer to annotate print and save the SimPad PLUS data log SessionViewer also enables capture of audio and video from...

Page 19: ...ablish a connection to the previous Link Box PLUS that it was connected to Select WiFi Tap to connect SimPad to a different Link Box Use SimPad PLUS without a Link Box PLUS SimPad PLUS can be used with a standardized patient without connecting to the Link Box PLUS Bluetooth SimPad PLUS can also connect to bluetooth enabled simulators Select Standardized patient ...

Page 20: ... connected in the following ways Using a standard network cable On a wired Ethernet network On a WiFi network Using a Standard Network Cable Connect to Wired Ethernet Network Connect SimPad PLUS and Link Box PLUS to network outlets The network needs to have DHCP service Note It is possible to be on a wired network and a WiFi network simultaneously Connection by wire ...

Page 21: ... ensure it is connected to SimPad PLUS with a network cable Select WiFi Network Network 40 41 Connect to Another Network Select the desired WiFi network from the list and enter the network password Any other ad hoc network can be created optional Select Flight Mode will disable WiFi ...

Page 22: ...nd Immediate online access to world wide validated content Standardized and repeatable training measures Easy search find and pay navigation Flexibility to purchase based on requirements Register SimPad PLUS on SimStore SimPad PLUS needs to be connected to a network in order to register with SimStore online See Connect to a Network section SimPad PLUS can also be registered offline SimPad PLUS wil...

Page 23: ...emes folder Upload logs from the Logs folder Disconnect the USB cable from the SimPad PLUS when transfers are finished Note If SimPad PLUS is turned off the battery can be charged from the USB connection Headset Create two way communication between the operator and simulator by connecting a headset The headset microphone will be routed to the manikin Plug headset into SimPad From instructor to man...

Page 24: ...s used wirelessly there is a short voice delay Configure the Auxillary Button Press and hold to speak Sounds 46 ConnectTwo Laerdal Li Ion Batteries Remaining battery capacity Batteries are discharged independently 44 53 Laerdal Li Ion Battery 47 Press and hold to speak In default Activate microphone mode Press and hold to mute Return to Session Overview Tap to view Device information ...

Page 25: ...tem has the same ECG library as SimMan 3G and other Laerdal simulators The available rhythms and rhythm parameters may vary from simulator to simulator Available ECG in SimPad PLUS System Basic Rhythms Rates Adult and Child Rates Infant Extra systoles Sinus 20 200 20 240 PVC PVC RonT Couplet PVC PAC PJC WPW 20 200 20 240 Hyperkalemia 20 200 20 240 Long QT 20 200 20 240 Ischemia 20 200 20 240 Infer...

Page 26: ...rmal Absent 70 Weak Absent 60 Absent Absent Infant pulses are automatically set to absent when Systolic BP is below 10 mm Hg Otherwise infant pulses are normal Adult pulses are automatically adjusted to BP as follows Systolic BP Carotid Pulse Radial Brachial Pulse 88 Normal Normal 88 Normal Weak 80 Normal Absent 70 Weak Absent 60 Absent Absent Heart Sounds Heart sounds are synchronized to ECG Hear...

Page 27: ... sound Vocal Sounds Vocal sounds are adjusted for age and gender of manikin Male Manikin Female Manikin Child Manikin Infant Manikin Vomit Vomit Vomit Cry Cough Cough Cough Cough Moan Moan Moan Content SOB Breathing SOB Breathing SOB Breathing Hiccups Scream Scream Scream Scream Yes Yes Yes No No No Sound format for user defined sound files must be raw format 16KHz 16 bits signed little endian ...

Page 28: ......

Page 29: ...20 10206 Rev A 2016 Laerdal Medical AS All rights reserved www laerdal com ...