laerdal Link Box User Manual Download Page 29

57

Features

56

Laerdal Li-Ion Battery - SimPad

The available rhythms and rhythm parameters may vary from simulator to simulator. 

Available ECG in SimPad System

Basic Rhythms

Rates

Adult and 

Child

Rates

Infant

Extra-

systoles

Sinus

20 – 200

20 – 240

PVC

PVC RonT

Couplet PVC

PAC/PJC

WPW

20 – 200

20 – 240

Hyperkalemia

20 – 200

20 – 240

Long QT

20 – 200

20 – 240

Ischemia

20 – 200

20 – 240

Inferior AMI, ST elevation

20 – 200

20 – 240

Left Bundle Branch Block (LBBB)

20 – 200

20 – 240

Rigth Bundle Branch Block (RBBB)

20 – 200 

20 – 240

Atrial  Tachycardia (Atach.)

140 – 260 

90 – 320

Supra Vent. Tachycardia  (SVT)

140 – 260

90 – 320

Atrial Flutter

75, 100, 150

75, 100, 150

Atrial  Fibrillation (AFib.)

50 – 240

50 – 240

Junctional

40 – 220

40 – 220

1° AV-Block

20 – 135

20 – 135

PVC

PVC RonT

Couplet PVC

PAC/PJC

2° AV Block type #1

3:2,4:3, 5:4

3:2,4:3, 5:4

2° AV Block type #2

4:3, 3:2, 2:1

4:3, 3:2, 2:1

3° AV Block

10 – 50

20 – 100

Ventricular Tachycardia  (VT)

120 – 240 

120 – 320

Torsade de pointes

180

180

Idioventricular

10 – 100

14 – 100

Ventricular Fibrillation (VF)

0.1 – 1 mV

0.1 – 1 mV

Asystole
Ventricular  Standstill
Ventricular Pacemaker

50 – 150

50 – 150

Charge Batteries

The batteries can be charged through the Link Box when the power is turned off and 

the Link Box is connected to the AC adapter. 

Note

The AC Adapter can only be used with SimPad or SimPad PLUS and Link Box or Link Box PLUS.

For more information about Charging Batteries see 

Quick Setup Guide.

Battery 1

Battery 2

Charging batteries - 

flashing yellow light
Batteries charged - 

steady yellow light

Charging battery - 

steady yellow light

Warnings

• 

Do not use the Laerdal Li-Ion Battery for other purposes than specified. 

• 

Use only the AC charger adapter supplied with the product.

• 

Do not use the battery in temperatures above what is specified in this User Guide or 

Important Product Information.

• 

Do not heat or incinerate. 

• 

Do not crush the battery. 

• 

Do not short circuit the battery contact. 

• 

Do not immerse in water. 

• 

The battery must be recycled and disposed of in accordance with local rules.

• 

Do not handle damaged or leaking Li-Ion batteries. 

Summary of Contents for Link Box

Page 1: ...SimPad User Guide EN www laerdal com...

Page 2: ...stem is an easy to use wireless tool that performs relevant medical simulation training including debriefing in various user settings With a large intuitive touch screen SimPad is a Pick up and Play e...

Page 3: ...5 Auxiliary button On Off Status LED Audio out USB Ethernet DC FrontView Back View Manikin Cable Battery Connection Blood PressureTube On Off Power LED WiFi LED Ethernet DC Audio in Audio out USB Batt...

Page 4: ...erview On Off Power LED WiFi LED Ethernet DC Audio in Audio out USB Battery Connection Side Panel Connector Auxiliary button On Off Status LED Audio out USB Ethernet DC FrontView Back View Manikin Cab...

Page 5: ...lashing green light Low battery flashing red light Off but battery charged steady yellow light On steady green light Error needs service steady red light Contact your local Laerdal representative When...

Page 6: ...A steady green LED indicates the device is ready to use Status LED The Power LED also indicates status Charging batteries flashing yellow light Starting and shutting down flashing green light Error n...

Page 7: ...trainer is connected to SimPad Note These configurations may be altered later About Link Box About SimPad Enter Link Box name optional Enter SimPad name optional Starting for the FirstTime Follow the...

Page 8: ...is connected to SimPad PLUS Note These configurations may be altered later Starting for the FirstTime Follow the on screen prompts to configure the device Select language Choose country pre select ti...

Page 9: ...by pressing On Off button SimPad SimPad PLUS WiFi Connection Connected to a network steady green light Tap to shutdown SimPad and or Link Box Tap to shutdown SimPad and or Simulator Connected to a Si...

Page 10: ...and the units will reconnect when turned on again When multiple Link Box Simulator are available choose the preferred option SimPad SimPad PLUS When the units are turned on for the first time they wi...

Page 11: ...the LogViewer Adjust display brightness clock and more Register and synchronize with SimStore Run Scenarios in Manual Mode Home screen may vary in appearance based on purchased licenses Select Scenar...

Page 12: ...state information Access to vital signs adjustments Abnormal parameter values displayed here Select other parameters to adjust Run Session Time since Scenario was started Patient status Categories of...

Page 13: ...Select theme for simulation Folder of themes Tap to open Information about Session entered here will be added to log Tap to start Session End Session Tap menu to End Session End Scenario Open current...

Page 14: ...ivated States Current state Select other parameters to adjust Pause Session Patient vital signs Abnormal values Collapse mini log End Session Register participant s interventions White arrow indicates...

Page 15: ...Tap to create a new state New state visible Adjust Parameters Manually Advanced Adjustments Tap to adjust values e g respiration rate For fine adjustments hold finger over slider Activate the new val...

Page 16: ...Tap to display and activate the Stopwatch Add New State to an ExistingTheme 1 Tap to add new state to theme 4 Tap to save state to theme New state is now ready Tap and hold to arrange states Tap x to...

Page 17: ...l Mode Tap to enlarge QCPR feedback Automatic Mode Tap to enlarge QCPR feedback Full Session with compressions and ventilations over time Compression depth Chest release Compression rate Ventilation v...

Page 18: ...QCPR QCPR 34 35 QCPR Log File Debriefing mode provides an additional log file with data from CPR training Indicates two main findings from the CPR performance Tap to access log QCPR Summary...

Page 19: ...ession Analysis OverTime CPR settings can be adjusted to individual needs Laerdal recommends using settings compliant with ILCOR guidelines Display Choices With overall score Without overall score Tog...

Page 20: ...and select Patient Monitor Select Cut Off limits Navigate to menu and select Patient Monitor Toggle On Off vital signs Connect a Simulated Patient Monitor Ensure the Simulated Patient Monitor PC and...

Page 21: ...date is necessary Caution Ensure that the correct Simulator is selected Selecting the wrong simulator may cause malfunction and require service SimPad From Home Screen go to System Settings About Link...

Page 22: ...o re establish a connection to the previous Link Box PLUS that it was connected to Select WiFi Tap to connect SimPad PLUS to a different simulator Use SimPad PLUS without a Link Box PLUS SimPad PLUS c...

Page 23: ...rk outlets The network needs to have DHCP service SimPad SimPad PLUS Connection by wire Connection by wire Connect to a Network All models of SimPad and Link Box are connected via SimLink ad hoc netwo...

Page 24: ...to another WiFi network ensure it is connected to SimPad with a network cable Select WiFi Connect to a WiFi Network Note Before moving Link Box PLUS to another WiFi network ensure it is connected to S...

Page 25: ...alistic clinical encounter and increase the simulation investment To access visit www mysimcenter com Visit SimStore to find Immediate online access to world wide validated content Standardized and re...

Page 26: ...can be downloaded from www laerdal com themeeditor and be used offline Note Theme Editor will only be accessible using Internet Explorer SimDesigner SimDesigner creates new scenarios with states and i...

Page 27: ...e and don t require a Link Box setup Vocal Sounds Vocal sounds from the Patient Simulator such as crying moaning etc can be activated from the SimPad directly or viaThemes and Scenarios For more infor...

Page 28: ...nnectTwo Laerdal Li Ion Batteries Remaining battery capacity Tap to view Device information Batteries are discharged in parallel 50 50 ConnectTwo Laerdal Li Ion Batteries Remaining battery capacity Ba...

Page 29: ...intes 180 180 Idioventricular 10 100 14 100 Ventricular Fibrillation VF 0 1 1 mV 0 1 1 mV Asystole Ventricular Standstill Ventricular Pacemaker 50 150 50 150 Charge Batteries The batteries can be char...

Page 30: ...rmal Weak 80 Normal Absent 70 Weak Absent 60 Absent Absent Infant pulses are automatically set to absent when Systolic BP is below 10 mm Hg Otherwise infant pulses are normal Adult pulses are automati...

Page 31: ...are adjusted for age and gender of manikin Male Manikin Female Manikin Child Manikin Infant Manikin Vomit Vomit Vomit Cry Cough Cough Cough Cough Moan Moan Moan Content SOB Breathing SOB Breathing SOB...

Page 32: ......

Page 33: ...20 05299 Rev D 2016 Laerdal Medical AS All rights reserved www laerdal com...

Reviews: