Thanks to its design and control features, the Laddomat 11
means optimal thermal layering in storage tanks, with a low
and even charging flow. This layering system is benefi cial as
it increases storage capacity.

Function

Thermal Layering

FINAL PHASE

M = Mixed return
flow to bottom of
heat source

Pump placement
and flow direction,
to bottom of heat
source

H = Hot flow from
top of heat source

C = Cold
return flow

OPERATING PHASE

START UP PHASE

M = Mixed Flow

C = Cold Flow

H = Hot flow

M = Mixed
Flow

C = Cold Flow

Laddomat 11-30

Laddomat 11-100

H = Hot flow

Technical Data

Thermostat cartridge:

Pressure class:

Max. temp:

45°, 53°, 57°, 63°, 66°, 72°, 78°, 83° or 87°C

PN 6

Max +100°C

Min +5°C

Laddomat 11-30:

Pump:

Connection:

Max. boiler output:

Kvs-value:

4 m

3 x Cu22 or 3 x R25

3,4 m³/h

30 kW

Laddomat 11-100:

Pump:

Connection:

Max boiler output:

Kvs-value:

4 m, < 35 kW

6 m, < 65 kW

7 m, < 120 kW

3 x Cu28 or 3 x R32

14 m³/h

120 kW (see pump above)