INSTRUCTIONS FOR THE INSTALLER 

 

 

2.  

2.2.2.

 

Location of the appliance in the 

room 

Choose  a  location  in  the  room  which 

favours  good  hot-air  distribution  by 
convection and radiation. 

2.3.

 

Installation of the appliance 

2.3.1.

 

Floor 

Make sure  that the  base  can withstand 

the  total  constructed  weight  of  the 
appliance and its casing. 

The apparatus should not be  placed on 

combustible material. 

2.3.2.

 

Safety distances 

Be  sure  to  respect  the  appliance 

installation  distances  from 

combustible 

materials

.  Looking  at  the  appliance  head-

on:

 

 

Distance to 

combustible 

materials 

(mm)  

From the right-hand side 

750 

From the left-hand side 

750 

From the rear 

400 

From the front 

750 

 

 

Figure No.3 -

 

Safety distances 

 

 

Bear  in  mind  that  it  may  even  be 

necessary  to  protect  non-combustible 
material  in  order  to  prevent  breakage, 
deformation,  etc.,  as  a  result  of 
overheating 

if 

the 

non-combustible 

material is not  designed to withstand high 
temperatures.  

2.3.3.

 

Checks before lighting for the first 

time 

 

Make  sure  that  the  glass/es  is/are 

not broken or damaged. 

 

Make  sure  that  the  flueway  is  not 

obstructed with packing or loose parts. 

 

Make  sure  that  the  airtight  joints 

on  the  flue  circuit  are  in  perfect 
condition. 

 

Make  sure  that  the  doors  close 

properly. 

 

Make sure that all moving parts are 

fitted in place. 

2.3.4.

 

Height adjustment and levelling the 

appliance 

The  appliance  must  be  perfectly  level, 

horizontally  and  vertically,  both  at  the 
front and on the sides (use a spirit level). 

2.3.5.

 

Connection to the flue 

The appliance must be connected to the 

chimney flue  using special piping designed 
to  resist  the  products  of  combustion  (e.g. 
stainless steel, enamelled steel, etc.). 

To connect the flue to the socket flange, 

insert the piping inside the flange and seal 
the joint with fire sealant or fire cement to 
make it completely airtight. 

The  installer must  ensure  that  the  pipe 

connected to the appliance is well secured 
and  there  is  no  chance  of  it  coming  free 
from  its  housing  (e.g.  as  a  result  of 
dilatation due to temperature, etc.). 

On this appliance, the flue socket can be 

fitted  either  on  top  or  at  the  rear  of  the 
appliance. 

Summary of Contents for LEVANTE

Page 1: ...LEVANTE Instruction Book ...

Page 2: ...LLER 5 2 1 Warning to installers 5 2 2 Room for installation 5 2 2 1 Ventilation of the room 5 2 2 2 Location of the appliance in the room 6 2 3 Installation of the appliance 6 2 3 1 Floor 6 2 3 2 Safety distances 6 2 3 3 Checks before lighting for the first time 6 2 3 4 Height adjustment and levelling the appliance 6 2 3 5 Connection to the flue 6 2 3 5 1 Rear flue socket 7 2 3 5 2 Top flue socke...

Page 3: ...3 Flue socket 15 4 1 4 Chrome parts 15 4 1 5 Painted sheet steel cast iron parts 15 4 1 6 Brass parts 15 4 1 7 Firebox glass 15 4 2 Maintenance of the chimney flue 15 4 3 Important advice 15 TROUBLESHOOTING 17 BASIC BREAKDOWNS 18 DECLARATION OF PERFORMANCE 20 CE MARK 22 ...

Page 4: ...ce with the specifications set out in the legislation applicable in each country and this instruction book 1 1 General characteristics Unit Levante Nominal Heat Output N H O to atmosphere kW 11 Efficiency at N H O 74 CO emission at 13 O2 at N H O 0 27 Gas mass flow at N H O g s 9 1 Gas temperature of flue at N H O ºC 400 Optimum flue draught Pa 12 Wood consumption beech at N H O Kg h 3 2 Dimension...

Page 5: ...of the fuel fuel loads fuel load frequencies flue draught and system of installation indicated in this Instruction Book Failure to respect these conditions may lead to problems with the appliance deterioration shorter useful life etc which are not covered by the Lacunza warranty Figure No 1 Dimensions of the Levante appliance in mm ...

Page 6: ...solutely crucial to ensure the suitable renewal of the air in the room in which the appliance is fitted the room must always have at least two permanent grilles or openings to the exterior in order to renew the air one for intake and the other for extraction For the installation of its appliances Lacunza recommends an additional section for these openings One of these two grilles must be situated ...

Page 7: ...hting for the first time Make sure that the glass es is are not broken or damaged Make sure that the flueway is not obstructed with packing or loose parts Make sure that the airtight joints on the flue circuit are in perfect condition Make sure that the doors close properly Make sure that all moving parts are fitted in place 2 3 4 Height adjustment and levelling the appliance The appliance must be...

Page 8: ...iping can be used inside the building the heat of the gases serving to heat rooms insulating only those sections where excess temperature may cause damage If the chimney is constructed then it is necessary to pipe and insulate it to ensure correct updraught The diameter of the pipe must be the same as the diameter of the flue socket on the appliance over its entire length in order to ensure correc...

Page 9: ...ustible material in order to prevent breakage deformation etc as a result of overheating if the material is not designed to withstand high temperatures It must be possible to clean the entire flue no sections being left inaccessible for cleaning purposes 2 4 2 Chimney crown The upper end of the chimney must clear the roof the roof ridge or any obstacle located on the roof by at least 1m Figure No ...

Page 10: ...himney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet Figure No 7 Distances between the chimney crown and objects within a radius of between 10 and 20m ...

Page 11: ...ely chopped wood produces greater heat output but also burns more quickly Optimum fuels Beech Other fuels Oak chestnut ash maple birch elm etc Pine and eucalyptus logs are low density and produce very long flames and may cause the parts of the appliance to wear out more quickly than normal Resinous wood may mean that the appliance and the flue need to be cleaned more often Non permitted fuels All ...

Page 12: ...INSTRUCTIONS OF USE 11 3 3 2 Description of the parts of the appliance 3 2 1 Operating components Figure No 9 Operating components on the appliance ...

Page 13: ...ht in the flue and lead to suffocation Proceed as follows in order to light the appliance satisfactorily Open the firebox door s and open all the firebox air intake inlets to the full Place paper or a firelighter and some wood chips in the firebox Light the paper or firelighter Leave the door slightly ajar the width of two or three fingers for about 15 minutes until the glass warms up The first ti...

Page 14: ...r intake By opening this inlet air enters the firebox via the firebox grille Secondary air intake By opening this inlet air enters the firebox via the top of the firebox door IMPORTANT Keeping the secondary air intake open helps keep the door glass cleaner for longer Double combustion air intake By opening this inlet air enters the combustion flame making for more efficient and less polluting comb...

Page 15: ... Figure No 11 Remove the top cover of the stove Unscrew and remove the 4 screws that hold the second sheet metal cover A Remove the deflector lifting it first at the front and then at the rear B and C Figure No 11 Removing the deflector Soot falling from the flue may build up on the deflector ...

Page 16: ...ning the glass the liquids used must not dampen the painted steel 4 1 6 Brass parts Use special brass cleaning products available on the market to clean the brass parts 4 1 7 Firebox glass Keep the secondary air intake open to keep the door glass cleaner for longer However the glass may get dirty the longer the appliance is used Special degreasing products designed for the purpose should be used t...

Page 17: ...lity for any modification to the product which it has not authorised This appliance is a heat producing appliance and contact may lead to burns This appliance may remain HOT for a period of time after it has gone out MAKE SURE THAT SMALL CHILDREN DO NOT GO NEAR IT ...

Page 18: ... continually burn chips carpentry scraps plywood pallets etc Cold flue Heat up the flue by burning a piece of paper in the firebox Smoke during burning The room is at low pressure In rooms with Controlled Mechanical Ventilation leave an outdoor window ajar until the fire is fully alight Too little wood loaded Load as recommended Loads notably smaller than those recommended lead to low smoke temper...

Page 19: ...BASIC BREAKDOWNS 18 6 BASIC BREAKDOWNS ...

Page 20: ...000043 6 Manilla puerta cenicero de Cromo France 502050000028 7 Cordón puerta hogar cenicero lateral Ø8mm 500900000010 8 Cordón plano entre cristal y puerta 8x2mm 500000000510 9 Tirador registro primario 504020000046 10 Piedra refractaria 220x110x30 502050000014 11 Levante Lujo piedra refractaria pequeña 220x33x30 500000000086 12 Tubo doble combustión 502050000039 13 Deflector 502050000003 14 Ganc...