background image

LACAVA 

6

Installation Instructions/Instrucciones de Instalación

5.  Mount the control box in an accessible location (1).
6.  Install supply line to the 

inlet

 and fasten the hose to 

the 

outlet

 using the buckle (2).

7.  Attach the sensor cable 

and transformer cable (3).

INLET

OUTLET

TRANSFORMER

SENSOR

CABLE

RESET

BUTTON

8.  Now press and hold the reset 

button (4) for 3 seconds and release,  

place hands under the tip at desired

sensing distance 2”-12”, wait 20 seconds 

while the sensor determines the field range.

9.  Once range is determined 

normal operation can begin.

3

3

4

How to Use

Place hands in the sensor field

Water runs for 10 seconds and 

then shuts down

Remove hands from sensing field for 3 seconds 

to repeat the cycle 

PROBLEM

CAUSE

SOLUTION

No water running

The batteries are exhaused

Replace the batteries

Watter supply cut off

Check water supply lines

Dirt in the filter

Clean the filter

Water pressure too low

Increase the water pressure

Water does not turn off

Dirt in the sensor window

Clean the sensor

Very low water flow

Water supply is obstructed

Adjust water supply

The filter is too dirty

Clean the filter

Too high water flow

Water pressure is too high

Adjust water pressure down

Short battery life

Incorrect batteries

Use 4 AA Alkaline batteries

The sensor light

does not turn on

The light is broken

Change the light or circuit board

The circuit board is wet 

or signal line is wet 

Dry out all supply lines

The batteries are exhaused

Replace the batteries

Poor connection to batteries

Check/plug in all connections

Troubleshooting

Sensor 

Range 

Adjustment

IMPORTANT:

 Install provided flow reducer on the water inlet. 

The black O-ring faces the incoming water flow.   

Flow reducer not installed on the inlet

Install flow reducer

Summary of Contents for EX31

Page 1: ...avor consulte nuestros T rminos y Condiciones que se encuentran en este folleto para informaci n adicional Para obtener asistencia t cnica por favor contacte a 773 637 9600 Table of Contents Contenido...

Page 2: ...cumento tienen el prop sito de dar al usuario una idea del producto y no est n hechos a escala Los tama os de pulgadas se redondean al m s cercano 1 16 2 50 INLET M1 2 5 128 30 o 3 3 4 95 6 3 4 172 4...

Page 3: ...te documento tienen el prop sito de dar al usuario una idea del producto y no est n hechos a escala Los tama os de pulgadas se redondean al m s cercano 1 16 EX31 EX21 IMPORTANT Install provided ow red...

Page 4: ...Note Please reference this sheet and the corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes 1 2 3 4 5 6 7 8 9 10 AE...

Page 5: ...x and remove the cover 1 3 Unplug the battery box uncrew the top and install four AA batteries 2 4 Close the battery box 3 plug it in and re install in the control box cover Warnings Do not install th...

Page 6: ...are exhaused Replace the batteries Watter supply cut off Check water supply lines Dirt in the filter Clean the filter Water pressure too low Increase the water pressure Water does not turn off Dirt in...

Page 7: ...favor cuide des este producto de acuerdo con las siguientes instrucciones S lo utilice agua tibia y un detergente suave es decir el jab n para lavar la vajilla para la limpieza Si se utiliza otro lim...

Page 8: ...ACAVA proporciona una Garant a Limitada de por Vida en sus grifos Esto garantiza que cualquier grifo instalado en una aplicaci n residencial no presentara defectos en el material o de fabricaci n mien...

Page 9: ...her it was our error If we verify it was our mistake we will promptly ship the missing item s to the purchaser by standard ground at our cost RETURN POLICIES If the product is not satisfactory for any...

Page 10: ...nte chofer de la compa a cualquier alteraci n visible en el empaque En el caso que falten art culos tambi n hay que informar a LACAVA y enviar todos los documentos relacionados con un plazo de 24 hora...

Reviews: