Installation Instructions/Instrucciones de Instalación

5.  Mount the control box in an accessible location (a)

in the correct orientation top and bottom as shown, max. 

19” (50 cm) away from the basin.
6.  Install supply line to the 

inlet

 and fasten the hose to 

the 

outlet

 using the buckle (b).

7.  Attach the sensor cable 

and transformer cable (c).

INLET

OUTLET

TRANSFORMER

SENSOR

CABLE

8.  Once range is determined 

normal operation can begin.

How to Use

Place hands in the sensor field

Water runs for 10 seconds and 

then stops automatically

Remove hands from sensing field for 3 seconds 

to repeat the cycle 

PROBLEM

CAUSE

SOLUTION

No water running

The batteries are exhaused

Replace the batteries

Watter supply cut off

Check water supply lines

Dirt in the filter

Clean the filter

Water pressure too low

Increase the water pressure

Water does not turn off

Dirt in the sensor window

Clean the sensor

Very low water flow

Water supply is obstructed

Adjust water supply

The filter is too dirty

Clean the filter

Too high water flow

Water pressure is too high

Adjust water pressure down

Short battery life

Incorrect batteries

Use 4 AA Alkaline batteries

The sensor light

does not turn on

The light is broken

Change the light or circuit board

The circuit board is wet 

or signal line is wet 

Dry out all supply lines

The batteries are exhaused

Replace the batteries

Poor connection to batteries

Check/plug in all connections

Troubleshooting

a

b

b

c

c

top

bottom

Summary of Contents for EX03A

Page 1: ...e este aparato cumpla con todos los códigos de plomería locales Por favor consulte nuestros Términos y Condiciones que se encuentran en este folleto para información adicional Para obtener asistencia técnica por favor contacte a 773 637 9600 Table of Contents Contenido Page 2 Product Specifications Especificaciones de Producto Page 3 Parts Breakdown Desglosamiento de Partes Page 4 Installation Ins...

Page 2: ...arest 1 16 Nota Los planos proporcionados en este documento tienen el propósito de dar al usuario una idea del producto y no están hechos a escala Los tamaños de pulgadas se redondean al más cercano 1 16 1 3 4 3 1 2 45 90 19 3 4 25 1 2 500 650 INLET M1 2 4 7 8 125 4 3 4 120 sensor Distance between aerator and basin surface 10 250mm 3 4 20 Ø2 50 Ø7 8 22 Ø1 1 4 32 2 1 2 65 7 7 8 200 9 1 8 232 1 1 4 ...

Page 3: ... corresponding part number when requesting parts Nota Por favor referirse a esta pagina y la parte correspondiente cuando ordene partes Recommended Accessories sold separately EX20A Mechanical mixing valve for 1 2 inlets EX25A Integrated thermostatic mixing valve 1 2 3 4 5 6 7 8 9 10 sensor ...

Page 4: ... wall Unfinished side facing the wall Note Please use care not to tear or pinch power or water lines while feeding them into the PVC housing pipes and fitting the spout snug against the wall 2 Remove the 4 phillips screws holding the cover on the control box and remove the cover a 3 Unplug the battery box uncrew the top and install four AA batteries b 4 Close the battery box c plug it in and re in...

Page 5: ...o water running The batteries are exhaused Replace the batteries Watter supply cut off Check water supply lines Dirt in the filter Clean the filter Water pressure too low Increase the water pressure Water does not turn off Dirt in the sensor window Clean the sensor Very low water flow Water supply is obstructed Adjust water supply The filter is too dirty Clean the filter Too high water flow Water ...

Page 6: ...a lavar la vajilla para la limpieza Si se utiliza otro limpiador revise la etiqueta para asegurarse de que es seguro para el uso del material para su limpieza y siempre prueba en un área discreta primero Asegúrese de limpiar cualquier exceso de productor de limpieza con una esponja o un trapo húmedo y luego enjuague con agua Seque la superficie con un paño suave hasta que se seque después de cada ...

Page 7: ...AVA proporciona una Garantía Limitada de por Vida en sus grifos Esto garantiza que cualquier grifo instalado en una aplicación residencial no presentara defectos en el material o de fabricación mientras que el consumidor original posea su casa Cualquier producto instalado en una aplicación comercial está cubierto bajo garantía por un año LACAVA garantiza que todos los otros productos no presentara...

Page 8: ...ther it was our error If we verify it was our mistake we will promptly ship the missing item s to the purchaser by standard ground at our cost RETURN POLICIES If the product is not satisfactory for any reason different from defects it can be returned to LACAVA up to 30 days from the shipping date after obtaining a Return Goods Authorization RGA valid for 60 days If the product is not returned to L...

Page 9: ...agente chofer de la compañía cualquier alteración visible en el empaque En el caso que falten artículos también hay que informar a LACAVA y enviar todos los documentos relacionados con un plazo de 24 horas a partir de la fecha de entrega Vamos a abrir una investigación interna y verificar el recuento de inventario para determinar si fue un error de nuestra parte Si nos damos cuenta que fue nuestro...

Reviews: