INSTALLER’S MANUAL
VOUGEOT - VOLNAY
Before connection
:
Check :
- Pipework is perfectly clean in order to prevent the injectors
becoming blocked and malfunctioning of the magnetic heads.
- The gas for which the appliance was set up: Rating plate and
markings.
- Cross-sectional area of gas supply pipework is compatible with the
appliance’s thermal output.
- Provide adequate air supply during use of the appliance.
Gas connection
:
Female coupling Ø 15/21, 1/2” ID NPT on
A
(Figure 8).
After connection :
Check the manifold pressure on pressure connection Ø 15/21, 1/8”
NPT on
B
(Figure 9).
Change of gas :
The appliance is designed to operate with the gases in Table 2.
Table 2
Country GAS
Pressure
(Pn)
U.S.
Natural gas
6’’ WC
U.S. L.P.
propane
10’’
WC
THE APPLIANCE MUST BE INSTALLED IN
ACCORDANCE WITH THE LOCAL CODES OR National
Fuel Gas Code, ANSI Z223.1 or latest edition.
In the Commonwealth of Massachusetts, the appliance must
be installed by a licensed plumber or gas fitter.
Manual shut-off valve should be installed in an accessible
location in the gas piping external to the appliance for the
purpose of turning on or shutting off gas to the appliance.
Check local codes.
Must be installed under an exhaust hood. In the
Commonwealth of Massachusetts, the exhaust hood must be
equipped with an "interlock" system. Check local codes.
Do not install this unit near combustible walls, partitions,
pieces of furniture, or decorative material unless these are
covered with adequate thermal insulation of the
noncombustible type.
Making sure the resulting installation meets fire regulations.