INSTALLER’S MANUAL
SULLY
Page 17 of 43 – US –
ELECTRICITY
It is hazardous to put the appliance into service without connecting it to suitable ground.
No liability can be accepted for accidents resulting from non-compliance with this requirement or incorrect grounding.
Connect the equipotential bonding terminal (
N
, Figure 24).
Before connection, check that the
:
Mains voltage is compatible with the appliance’s rated voltage and thermal output.
Connection:
-
Use a 4-wire cord rated for 30 A 125 / 250 VAC, type SRD, SRDT, S, SO
or ST.
-
Where local Codes do not permit grounding through neutral, use a 4-wire
power supply cord or “pigtail” kit. Cord must be agency approved for use
with household ranges.
-
Remove access door
O
(Figure.25, gas oven range) or
P
(Figure 26, gas and
electric range).
-
Connect to terminal block in accordance with
figure 28
.
-
Secure the cable by means of cable clamp, item
Q
(Figure 27).
-
Refit access door
THE APPLIANCE WHEN INSTALLED, MUST BE
ELECTRICALLY GROUNDED IN ACCORDANCE
WITH THE LOCAL CODES
OR The National Electrical
Code, ANSI/NFPA 70-1996 or latest edition
.
ALL WORK ON OR REPAIR OF AN APPLIANCE
MUST BE CARRIED OUT BY A QUALIFIED
INSTALLER.