I N STALLER’S M AN UAL
CHANGE OF GAZ
Table 1
Country
GAS
Pressure (Pn)
U.S.
Natural gas
6’’ WC
U.S.
L.P.
propane
10’’ WC
Changing the gas type of top :
Convertible regulator
The reversible cap is labeled either « LP » or « Nat » and is easily recognized by the raised center
screw slot (for natural) or the center depth (for LP).
To change LP to Natural or vice versa, the seal screw in the regulator lid is unscrewed, reversed
and reinstalled to convert from one setting to another/ figures
2
and
3
.
L
acanche ranges are supplied with the gas itting requested when the order is placed. The settings
must be ine-tuned when the range is installed.
T
he appliance is designed to operate with the gases in table
1.
IMPORTANT : Close the mains gas valve before carrying out any works.
IMPORTANT
In case of use with a gas other than that for which the appliance was initially set up, it is
crucial to replace the injectors and modify the adjustments as deined below. Subsequently
check the circuit for gas leaks
A pressure regulator igure
1
is located in the
right rear corner under the hob, to gain access
to the pressure regulator, remove the top.
Nat Setting
LP Setting
1
2
3
Notice provisoire Beaune - Bussy UL - FT164h - Date : 16/10/12
12/42