INSTALLER’S MANUAL
CHANGE OF GAS
CAUTION
: When refitting place the base underneath the groove on the fascia/
figure
17
.
16
17
Adjusting air ring
Table 5
Opening in mm /
inches
GAS
Pressure
Oven
Natural gas
6» WC
4 /
3
/
16
L.P. propane
10» WC
6 /
1
/
4
Adjustment of oven primary airflow :
►
C
arry out the adjustment ring by moving the 1ir through the two holes in the sole
15
and
16
, table n°
5
.
14
L
15
Adjusting pilot burner air supply :
T
urn rin
g
M
/ figure
18
to fully open for Butane/Propane, to half open for natural gas
.
18
M
Notice provisoire Beaune - Bussy UL - FT164h - Date : 16/10/12