Maintenance
63
Figure 3-36 Joystick
Valve Bank
The hydraulic valve bank is controlled by proportional solenoids.
The main body valve (see Figure 3-37) is equipped with proportional solenoids. These solenoids are
activated through the control module.
The packer valve section (see Figure 3-37) is fitted with solenoids that are electrically activated by
two proximity switches mounted to the body via the control module. These solenoids are 12
volt,
on/
off.
N
OTE
:
When facing the main body valve, the packer valve section is located on the right side of the
body valve (see Figure 3-37).
Figure 3-37 Valve bank
Release
Grab
Main body valve
Packer valve section