DEFROSTING

 

 

It

 

is

 

important

 

to

 

defrost

 

and

 

clean

 

the

 

unit

 

when

 

¼

 

to

 

½

 

inch

 

of

 

frost

 

has

 

accumulated

 

around

 

the

 

condenser

 

tubes

 

or

 

when

 

the

 

unit

 

will

 

not

 

maintain

 

proper

 

temperature.

 

When

 

defrosting

 

becomes

 

necessary,

 

press

 

the

 

DEF

 

key

 

for

 

2

 

seconds.

 

The

 

compressor

 

will

 

stop.

 

Remove

 

the

 

product

 

and

 

leave

 

the

 

door

 

open

 

while

 

defrosting

 

the

 

evaporator.

 

The

 

frost

 

should

 

melt

 

and

 

drain

 

through

 

the

 

drain

 

tube

 

to

 

the

 

drain

 

pan

 

under

 

the

 

unit.

  

Once

 

the

 

unit

 

is

 

defrosted,

 

clean

 

it

 

using

 

the

 

cleaning

 

suggestions

 

in

 

the

 

table

 

above.

 

Wipe

 

away

 

any

 

excess

 

water.

 

After

 

25

 

minutes,

 

the

 

unit

 

will

 

automatically

 

return

 

to

 

normal

 

operation.

 

If

 

you

 

wish

 

to

 

end

 

the

 

defrost

 

cycle

 

early,

 

simply

 

press

 

the

 

DEF

 

key

 

again

 

for

 

2

 

seconds.

 

The

 

defrost

 

icon

 

will

 

extinguish

 

on

 

the

 

display

 

and

 

the

 

compressor

 

will

 

return

 

to

 

normal

 

cycling

 

operation.

  

 

 

Summary of Contents for LABH?5?URB

Page 1: ...freight bill and acknowledged by the carrier s agent driver at time of delivery Make sure you get a signed copy Send a written request for an inspection to the carrier B Concealed Damage This type of...

Page 2: ...cription The model and serial number is located on the serial tag which can be found on the interior left OR right upper wall of the unit For convenience you may want to record the following informati...

Page 3: ...knowledging the damage This has to happen at the time of delivery or it won t happen at all Keep a copy for your records and send another to the carrier s damage claims department along with a formal...

Page 4: ...Codes Consult the cabinet Serial Data plate for voltage cycle phase and amp requirements before making connection VOLTAGE SHOULD NOT VARY MORE THAN 5 FROM SERIAL PLATE RATINGS A separate circuit is r...

Page 5: ...weather is very hot This is only normal functioning of the motor overload protector The motor compressor will cycle normally as soon as the excess heat has been removed Shelf Installation Hook shelf...

Page 6: ...sides of the unit to allow for proper air flow and therefore more even cooling of the product When loading the top shelf avoid blocking the evaporator fan s if installed There should be at least 4 in...

Page 7: ...m condition Beeper for audible indication of an alarm condition A preprogrammed 5 minute delay from the time a setpoint is attained until an alarm condition is declared This prevents spurious alarms f...

Page 8: ...perature control setpoints are preset at the factory to provide the desired air and product temperatures inside of the unit and require no further adjustment Please contact the manufacturer s Technica...

Page 9: ...eturn to Operating Mode To change the Hi or Low Alarm setpoints press SET and DOWN keys for 3 seconds to enter programming mode Hy will display Press the UP or DOWN keys several times to cycle through...

Page 10: ...refrigerator air circulation For the proper air circulation place the products evenly on each shelf Do not push against the refrigerator s rear or side walls Evaporator is blocked by frost or ice Rem...

Page 11: ...4F Stop using immediately The display shows LL and the compressor does not run The ambient temperature is below 40C 40F Stop using immediately MOISTURE DURING THE SUMMER SEASON The amount of moisture...

Page 12: ...e commercial household cleaners ammonia or alcohol to clean handles Use a soft cloth to clean smooth handles Do not use a dry cloth to clean smooth handles Stainless Steel Care and Cleaning Use the pr...

Page 13: ...Excellent removal on all finishes Grease oil Any good commercial detergent Apply with a sponge or cloth Restoration Passivation Benefit Super Sheen Passive Film Breakdown Corrosion on metals is every...

Page 14: ...r open while defrosting the evaporator The frost should melt and drain through the drain tube to the drain pan under the unit Once the unit is defrosted clean it using the cleaning suggestions in the...

Page 15: ...ion of the original warranty ADDITIONAL THREE YEAR COMPRESSOR WARRANTY In addition to the two 2 year warranty stated above Horizon Scientific Inc warrants its hermetically and semi hermetically sealed...

Page 16: ...te of manufacture to alteration neglect abuse misuse accident damage during transit or installation fire flood or other external causes It does not apply to defects resulting from failure to properly...

Reviews: