13.  SPECIFICATIONS

Optical System

Magnification

Eyepieces

Diopter Correction

IPD

Viewing Angle

Working Distance

Magnification range

Object field diameter

Eyegaurds

Illumination control

Greenough

Zoom 6:1

WF 10x/22mm

±5D

50 - 75 mm

Binocular, 45°

110mm

8x to 50x

4.4 to 27.50mm

Foldable

Incident Light-LED Ring Light with options of ARC and circular

Illumination with intensity control

Front Angle Arc illumination with cluster of 11 LEDs

Rear Angled Arc illumination with cluster of 12 LEDs

Circular Illumination with cluster of 23 LEDs

Goose neck for extra illumination

Transmitted Light: DF/BF (Dark field/ Bright field)
base with On Off control

Summary of Contents for Luxeo 6z

Page 1: ...Printed on Sept 2017 Luxeo 6z Stereo Zoom Microscopy User Manual To ensure proper use of this instrument as well as to avoid injury while operating Instrument understanding this manual completely bef...

Page 2: ...t is exceptionally well suited to Manufacturing tasks testings quality control and other industrial applications In developing the LABOMED Luxeo 6z we have placed great emphasis on simple self explana...

Page 3: ...2 Mounting of the Goose Neck LED assembly 13 9 3 Setting up the Dark field Bright field attachment if supplied 14 10 OBSERVATION USE OF MICROSCOPE 15 17 10 1 Power on the microscope 15 10 2 Diopter se...

Page 4: ...of Ball bearing friction less sideways focusing to avoid any loss in motion The sturdy new stylish design provides comfort as well as stability The lateral magnification changer allows comfortable and...

Page 5: ...o injury or instrument damage WARNING 1 Intended use of this product This product is intended only for microscopy Do not use it for any other purpose 2 Do not disassemble Disassembly may result on dam...

Page 6: ...gus 2 Transport If at all possible use the original packaging for shipping or transporting individual modules In order to prevent damage from vibrations the customer should disassemble all moving part...

Page 7: ...ect to change without notice Although every effort had been made to ensure the accuracy of this manual if you note any points that are unclear or incorrect contact your nearest Labomed representative...

Page 8: ...ng a solution of diluted hand soap liquid Remove any remaining residue with a dry cotton swab c To remove oil use a solution of diluted hand soap liquid initially If this does not produce a satisfac t...

Page 9: ...ed by Labomed as being technically safe in this context Maintenance The labomed Luxeo 6z stereo microscope is basically maintenance free To ensure that it always operates safety and reliably we recomm...

Page 10: ...ED Assembly 4147000 835 6 Front Support 7 DF Base Compensator 8 DF Base if ordered 4147000 820 9 Thermocol box Lower 10 Specimen Plate Black White 4147000 826 11 Specimen Plate DF Base if DF base prov...

Page 11: ...rt No 4146101 800 Eyepieces Magnification changer Membrane switch for Goose Neck LED illumination control Coarse adjustment Knob Goose Neck LED Mains ON OFF switch Aligning guide holes for DF base Bas...

Page 12: ...art No 4146102 800 8 Eyepieces Magnification changer Trinocular Tube Membrane switch for Goose Neck LED illumination control Coarse adjustment Knob Goose Neck LED Mains ON OFF switch Aligning guide ho...

Page 13: ...HT FIELD DF BF BASE Part No 4146100 826 Note DF BF base is not a standard configuration part of Luxeo 6z It is supplied on order For use of DF BF base refer page no 14 Specimen Plate Dark Field Base D...

Page 14: ...nsparent Specimen Plate Membrane switch for ring light Magnichanger with Observation Tube PRE CONFIGURED MIRROR BASE FOR DARK FIELD ILLUMINATION Dark field observation in Luxeo 6z is provided through...

Page 15: ...ichanger with Observation Tube 4146000 795 Luxeo 6z Issue 1 1 Printed on Sept 2017 Trinocular Tube PRE CONFIGURED MIRROR BASE FOR DARK FIELD ILLUMINATION Dark field observation in Luxeo 6z is provided...

Page 16: ...e The ocular tubes are equipped with eyepieces installed Ocular tab prevents the eyepieces from falling rotating freely or easily pulled out 9 Refix the Goose Neck Assembly as per instructions below 1...

Page 17: ...ng the Guide pins of Dark Field base K with the Guide holes L Refer fig 5 3 The 9 pin male connector below dark field base will automatically connect to the female 9 pin inlet F while lifting up the d...

Page 18: ...lled by the switch D to glow both sided Goose Neck LED s Press the button in the following sequence to illuminate the Goose Neck LED Press button D to illuminate both Goose Neck LED Second press of bu...

Page 19: ...etup the magnification factor at highest magnification of zoom pod using knob I 6 Looking through the eyepieces adjust the focusing of micros cope head using coarse knob J to focus the specimen 7 Brin...

Page 20: ...95 Luxeo 6z Issue 1 1 Printed on Sept 2017 10 6 USE OF AUXILIARY OBJECTIVES 0 5x 1 5x 2x Following Auxiliary objectives can be threaded in through Ring Light 1 0 5x To be used with PL stand only as wo...

Page 21: ...ND LUXEO 6Z B A C 11 OBSERVING EXTRA HEIGHT SPECIMEN Place the Stand on the level surface Fit the zoom pod with bracket to the pillar as shown and tighten it with clamping knob provided on the bracket...

Page 22: ...19 Luxeo 6z 4146000 795 Luxeo 6z Issue 1 1 Printed on Sept 2017 12 MAGNIFICATION CHART...

Page 23: ...enough Zoom 6 1 WF 10x 22mm 5D 50 75 mm Binocular 45 110mm 8x to 50x 4 4 to 27 50mm Foldable Incident Light LED Ring Light with options of ARC and circular Illumination with intensity control Front An...

Page 24: ...ive humidity 90 max no condensation Altitude 2000m max Temperature 0 40 C indoor use only Relative humidity 85 max no condensation Pollution level Degree 2 Installation C Use only the recommended powe...

Page 25: ...22 Luxeo 6z 4146000 795 Luxeo 6z Issue 1 1 Printed on Sept 2017 15 SYSTEM DIAGRAM...

Page 26: ...he specimen on the stage Bring the specimen in focus Adjust the brightness for incident light Observe Specimen Adjust the observation tube and eyepieces Adjust the interpupillary distance Adjust the d...

Page 27: ...n The LED control is wrongly select The power cord id not attached The LED are not switched on The power button is not switched on The fuse is blown The specimen is not focused properly The specimen i...

Page 28: ...A Phone 510 445 1257 Fax 510 991 9862 Email sales laboamerica com www laboamerica com Labomed Europe b v T a v Cor Treure Essebaan 52 2908 LK Capelle a an den Ijssel THE NETHERLANDS Phone 31 10 458 4...

Reviews: