background image

10

 Luxeo 6i

6.  MIRROR BASE Luxeo 6i BINOCULAR MICROSCOPE

4147100-795

 Luxeo 6i

Issue 1.0

Printed on Jan.,2021

PRE-CONFIGURED MIRROR BASE FOR DARK FIELD ILLUMINATION (4147300)

Dark field observation in Luxeo 6i is provided through a specialized stand controlling reflection mirror &
light shielding plate to direct on inverted hollow cone of illumination towards specimen at oblique 
angles. It has the same function as DF / BF base but advantage is that it is factory configured dedicated 
to DF application only.

 

Eyepieces

Magnification changer

Observation Head

Membrane switch for
Goose Neck LED 
illumination control

Coarse adjustment 
Knob

Crank locking knob

Crank lifting knob

Mains ON/OFF
switch

 DF/BF Lever

Base

Black & White Plate

CMO 

Goose neck 

Membrane switch for
Coaxial light

Magnichanger 

Zoom to step change over 
tab

Summary of Contents for Luxeo 6i

Page 1: ...Printed on Jan 2021 Luxeo 6i Stereo Zoom Microscopy User Manual To ensure proper use of this instrument as well as to avoid injury while operating Instrument understanding this manual completely befo...

Page 2: ...ce free performance Sturdy and reliable it is exceptionally well suited to Industrial Hospital and Laboratory applications In developing the LABOMED Luxeo 6i we have placed great emphasis on simple se...

Page 3: ...USE OF MICROSCOPE 12 15 8 1 Power on the microscope 12 8 2 Diopter setting of eyepiece 12 8 3 IPD adjustment 13 8 4 Focusing of microscope 13 8 5 Focusing torque adjustment 14 8 6 Use of crank mechan...

Page 4: ...one common main objective LED coaxial illumination with a life span of 50 000 hours Designed for professionals this microscopes offers many features and functions for its diverse applica tions Extra...

Page 5: ...may lead to death or serious injury CAUTION Disregarding instructions marked with this symbol may lead to injury or instrument damage WARNING 1 Intended use of this product This product is intended o...

Page 6: ...us 2 Transport If at all possible use the original packaging for shipping or transporting individual modules In order to prevent damage from vibrations the customer should disassemble all moving parts...

Page 7: ...ct to change without notice Although every effort had been made to ensure the accuracy of this manual if you note any points that are unclear or incorrect contact your nearest Labomed representative S...

Page 8: ...ng a solution of diluted hand soap liquid Remove any remaining residue with a dry cotton swab c To remove oil use a solution of diluted hand soap liquid initially If this does not produce a satisfac t...

Page 9: ...ty and reliably we recommend periodic inspections or if appropriate conclude a maintenance contract with LABOMED We recommend concluding a service contract with Labomed For maintenance and repair only...

Page 10: ...o 6i Microscope 4 DF Base Compensator 5 DF Base if ordered 4146100 820 6 Specimen Plate Black White 4147000 851 7 Specimen Plate DF Base if DF base provided 4146000 827 8 User manual 4147100 795 9 Dus...

Page 11: ...ification changer Observation Head Membrane switch for Goose Neck LED illumination control Coarse adjustment Knob Goose Neck LED Crank locking knob Crank lifting knob Mains ON OFF switch DF base ON OF...

Page 12: ...T FIELD DF BF BASE Part No 4147100 826 Note DF BF base is not a standard configuration part of Luxeo 6i It is supplied on order For use of DF BF base refer page no 14 Specimen Plate Dark Field Base DF...

Page 13: ...on inverted hollow cone of illumination towards specimen at oblique angles It has the same function as DF BF base but advantage is that it is factory configured dedicated to DF application only Eyepi...

Page 14: ...Ocular tab prevents the eyepieces from falling rotating freely or easily pulled out 11 Luxeo 6i 4147100 795 Luxeo 6i Issue 1 0 Printed on Jan 2021 7 INSTALLATION P k F L O N 1 Remove Black White speci...

Page 15: ...he zooming magnification is changed This adjustment ensures sharp image throughout the zooming range 12 8 OBSERVATION USE OF MICROSCOPE Luxeo 6i 4147100 795 Luxeo 6i Issue 1 0 Printed on Jan 2021 A B...

Page 16: ...eyepieces with your eyes until you can see the complete image field without corner cutting 8 4 FOCUSING OF MICROSCOPE I J 1 Switch on the desired illumination as per specimen selected 2 Adjust both e...

Page 17: ...ut it can be loosened to user s convenience if required Changing the Magnification Zoom Luxeo 6i have an integrated 6 1 zoom Zooming 1 Look into the eyepieces 2 Focus on the specimen 3 Rotate the magn...

Page 18: ...and planapochromatic objectives and also lowerpriced inter changeable achromatic objectives Achromatic objectives are particularly suited for specimens with high contrast structures Flat field planach...

Page 19: ...Luxeo 6i B A C 9 OBSERVING EXTRA HEIGHT SPECIMEN Place the Stand on the level surface Fit the zoom pod with bracket to the pillar as shown and tighten it with clamping knob provided on the bracket Re...

Page 20: ...agnification changer position a BinocularTube factor 1 6 Field number FN Eyepiece Field number of the eyepiece Field numbers are printed on the eyepieces along with magnification factor Magnification...

Page 21: ...6 14 4 25 0 9 0 31 25 7 2 40 06 5 6 50 4 5 62 5 3 6 0 4 3 2 80 0 5 12 50 0 6 4 40 0 8 21 31 2 10 24 25 0 12 8 20 0 0 5 4 64 0 6 4 40 0 8 32 0 10 26 25 0 12 8 20 0 16 16 0 0 7 5 6 45 7 8 96 28 6 11 2...

Page 22: ...fication range Object field diameter Eyegaurds Illumination control Galiean Zoom 6 1 WF 10x 22mm 5D 50 75 mm Binocular 45 or tiltable ergo head 0 210 with standard 1x objectives 106mm 6 4 to 40x 5 5 t...

Page 23: ...ive humidity 90 max no condensation Altitude 2000m max Temperature 0 40 C indoor use only Relative humidity 85 max no condensation Pollution level Degree 2 Installation C Use only the recommended powe...

Page 24: ...80x 4147053 ACHR 0 63x 4147052 ACHR 0 50x 4147051 ACHR 0 32x 4147050 12 5x EYEPIECE PLAN APO 1 0x 4147055 PLAN APO 1 25x 4147056 POWER SUPPLY 4140500 800 FLEX BRACKET 6i 4147000 803 SWING ARM 41403 00...

Page 25: ...e specimen on the stage Bring the specimen in focus Adjust the brightness for incident light Observe Specimen Adjust the observation tube and eyepieces Adjust the interpupillary distance Adjust the di...

Page 26: ...n is blocked by the specimen The power cord id not attached The microscope is not switched on The power button is not switched on The fuse is blown The specimen is not focused properly The specimen is...

Page 27: ...ne 510 445 1257 Fax 510 991 9862 Email sales laboamerica com www laboamerica com EU REP A28240 LABOMED ISO 9001 Labomed Europe b v Essebaan 50 2908 LK Capelle aan den IJssel The Netherlands Phone 31 1...

Reviews: