background image

10

 Luxeo 

4140000-795 

 Luxeo 

Issue 1.3 

Printed on Jan.,2020

Magnification Changer

Eyepieces

Power Cord

Eyepiece

Observation body

Objective

Illumination 
Control

Transmitted
Illumination 

On/Off switch

Coarse 
adjustment
knob

 STANDARD COMPONENTS - LUXEO 2S/4Z 

7

R

• 

After removing your microscope from its packaging, make sure that all of the following contents are 

    present. 

Summary of Contents for Luxeo 2S

Page 1: ...nted on Jan 2020 Luxeo Stereo Zoom Stereo Microscopy User Manual To ensure proper use of this instrument as well as to avoid injury while operating Instrument understanding this manual completely befo...

Page 2: ......

Page 3: ...2 SAFETY INFORMATION 2 5 3 LUXEO 2S 6 4 LUXEO 4Z 7 5 LUXEO 4Z TRINOCULAR 8 6 UNPACKING YOUR MICROSCOPE 9 7 STANDARD COMPONENTS LUXEO 2S 4Z 10 8 SYSTEM DIAGRAM OF OPTIONAL ACCESSORIESS 11 9 INITIAL SET...

Page 4: ...ss in motion The sturdy new stylish design provides comfort as well as stability The lateral magnification changer allows comfortable and friction less movement between switching magnification The LED...

Page 5: ...rd from wall outlet in advance Whenever you replace your microscope LED allow lamp socket and LED to cool before touching Fig 1 Applicable LED cluster replacement for incident illumination Applicable...

Page 6: ...solvents to clean the microscope components other than the glass compo nents To clean non glass components use a lint free soft cloth slightly moistened with a diluted neutral detergent 3 Do not disa...

Page 7: ...ll water soluble dirt with distilled water If this is unsuccessful repeat using a solution of diluted hand soap liquid Remove any remaining residue with a dry cotton swab c To remove oil use a solutio...

Page 8: ...o as to avoid the possibility of impairing its operational efficiency and accuracy 4 Periodicalchecking To maintain the performance of the instrument we recommend customers have their microscopes serv...

Page 9: ...eo 4140000 795 Luxeo Issue 1 3 Printed on Jan 2020 LUXEO 2S 3 R Magnification Changer Eyepieces Observation body Objective Illumination Control Transmitted Illumination On Off switch Coarse adjustment...

Page 10: ...eo 4140000 795 Luxeo Issue 1 3 Printed on Jan 2020 LUXEO 4Z 4 Magnification Changer Eyepieces Observation body Objective Illumination Control Transmitted Illumination On Off switch Coarse adjustment k...

Page 11: ...o Luxeo Issue 1 3 Printed on Jan 2020 LUXEO 4Z TRINOCULAR 5 Magnification Changer Eyepieces Observation body Objective Illumination Control Transmitted Illumination On Off switch Coarse adjustment kno...

Page 12: ...9 Luxeo 4140000 795 Luxeo Issue 1 3 Printed on Jan 2020 UNPACKING YOUR MICROSCOPE 6 R...

Page 13: ...epieces Power Cord Eyepiece Observation body Objective Illumination Control Transmitted Illumination On Off switch Coarse adjustment knob STANDARD COMPONENTS LUXEO 2S 4Z 7 R After removing your micros...

Page 14: ...an 2020 SYSTEM DIAGRAM OF OPTIONAL ACCESSORIES 8 10x 4140010 16x 4147016 20x 4147020 EYEPIECE ATLAS CMOS CAMERA 3146100 VEGA CMOS CAMERA 1 2 3146200 CAMERAADAPTER 4143070 POLORISER ATTACHMENT 4142030...

Page 15: ...ight entering into your line of vision Plug in the power cord and insert the power adapter to the AC socket Gently press the power on switch A the green LED B will indicate the power on indication The...

Page 16: ...anti clockwise to achieve the desired magni fication Use the coarse motion knob B to focus the specimen B Luxeo 2S While looking through the eyepiece rotate the magnification in clockwise or anticloc...

Page 17: ...and adjust camera up down to get best focus 6 Lock the camera in required position 7 System is Parfocal now Atlas 16MP CMOS USB Camera 1 2 33 16 0 MP Color CMOS Sensor active area 5 70 x 4 28mm with r...

Page 18: ...n focus Adjust the brightness for incident light Observe Specimen Adjust the observation tube and eyepieces Adjust the interpupillary distance Adjust the diopter setting Switch on the incident and or...

Page 19: ...select The power cord id not attached The LED are not switched on The power button is not switched on The fuse is blown The specimen is not focused properly The specimen is too small The specimen is t...

Page 20: ...ne 510 445 1257 Fax 510 991 9862 Email sales laboamerica com www laboamerica com Labomed Europe b v Essebaan 50 2908 LK Capelle aan den IJssel The Netherlands Phone 31 10 458 4222 Fax 31 10 450 8251 E...

Reviews: