BA_048 Rev 1K7 Submersible pressure transmitter
Page 2/3
1
General Information
This document contains necessary information for the proper installation and use of this
device. In addition to this instruction, be sure to observe all statutory requirements, appli-
cable standards, the additional technical specifications on the accompanying data sheet
(see www.labom.com) as well as the specifications indicated on the type plate.
1.1 General Safety Notes
The installation, set up, service or disassembly of this device must only be done by
trained, qualified personnel using suitable equipment and authorized to do so.
Ensure that the device is suitable for the process and undamaged.
1.2 Intended Use
The device is suitable for measuring the filling level in wells, storage tank or bodies of wa-
ter as specified in the data sheet.
1.3 Conformity with EU Regulations
The CE-marking on the device certifies its compliance with the applicable EU Directives for
placing products on the market within the European Union.
You find the complete EU Declaration of Conformity (document no. KE_024) at
www.labom.com.
1.4 ATEX Approval
Devices of the type CG2011 are certified for use in explosive environments.
If you purchased a device with ATEX approval, please refer to the accompanying docu-
ment XA_008 for ATEX-relevant information.
2
Transportation and Storage
Store and transport the device only under clean and dry conditions preferably in the origi-
nal packaging. Avoid exposure to shocks and excessive vibrations.
Permissible storage temperature:
-40…85 °C
3
Installation and Commissioning
Ensure that the device is suitable for the intended application with respect to pressure
range, overpressure limit, media compatibility, temperature range and process connection.
The submersible transmitter is not suitable for crystallising media.
3.1 Mechanical Installation
Only remove the protective cap or sheath from the diaphragm directly before installation so
as to avoid any contamination or damage. The diaphragm must have access to the pro-
cess media; you should therefore remove all covers from the transmitter.
Do not touch the flush mounted diaphragm with your fingers or other objects. Deformation
of the diaphragm can affect the zero point and the measuring properties of the unit.
Submersible transmitters are held by the connecting cable. Do not apply any force on the
screwed cable gland of the transmitter. Pay attention to avoid any tension when installing
in tanks or containers.