LID-3300IP Ice Detector
D80186JE-3
Installation and Operating Instructions
Copyright ©
2016 Labkotec Oy
31/37
APPENDIX C. TERMINAL COMMANDS
Comm.
nbr
Command
Description
Command
parameters
Example
Access
from web
UI raw
command
window
1
SP<nr> <xxx>
Set parameter value
<nr> = parameter
number, <xxx> =
value
SP1 20
yes
2
RP<nr>
Read parameter
value
<nr> = parameter
number
RP1
yes
3
SAOL <xxx>
Set scaling for 4mA
output, ice sensor
channel
<xxx> = scaling value
for 4mA output
SAOL 10
yes
4
SAOH <xxx>
Set scaling for 20mA
output, ice sensor
channel
<xxx> = scaling value
for 20mA output
SAOH 100
yes
5
RAOL
Read ice sensor 4mA
scaling value
None
RAOL
yes
6
RAOH
Read ice sensor
20mA scaling value
None
RAOH
yes
7
SWR
Software reset
None
SWR
yes
8
SUOT <x>
Set temperature
degree unit
C = Celsius, F =
Fahrenheit
SUOT C
yes
9
RUOT
Read temperature
degree unit
None
RUOT
yes
10
SDF
Set default values for
parameters
None
SDF
yes
11
HEAT
Start manual heating
None
HEAT
yes
12
TEST
Start manual ice
alarm test
None
TEST
yes
13
SDNW
Set network settings
to default values
None
SDNW
yes
14
SDPW
Set passwords to
default values
None
SDPW
no
15
SIP <XXX>
Set control unit IP-
address
<xxx> = IP-address in
format
aaa.bbb.ccc.ddd
SIP
192.168.11.28
no
16
RIP
Read control unit IP-
address
None
RIP
no
17
SGW <xxx>
Set unit default
gateway IP-address
<xxx> = IP-address in
format
aaa.bbb.ccc.ddd
SGW
192.168.1.1
no
18
RGW
Read default gateway
IP-address
None
RGW
no
19
SNM <xxx>
Set subnet address
mask
<xxx> = subnet mask
in format
aaa.bbb.ccc.ddd
SNM
255.255.255.0
no
20
RNM
Read subnet mask
None
RNM
no
21
RMC
Read control unit
MAC-address
None
RMC
no