1.  Prepare the Coax Cable: If you are using a rubber weather boot  
  (not supplied), slide the rubber weather boot, over the aerial end  
  of the cable. Strip the end of the cable as shown in Fig. 3. Once  
  you have stripped the cable, twist the braid and pull it back on  
  itself, make sure that no braid is touching the copper core, this  
  will cause a short on the cable and you will not get any signal. 

2.  Next twist the ‘F’ connector tightly onto the prepared cable end 
  and trim the central conductor as shown in Fig. 4. 

3.  When you are ready to connect up your aerial, 

offer up the cable, 

  with ‘F’ plug attached, ensure that the inner wire enters the socket’s  

  centre contact (

Fig. 6)

. Screw the nut part of the plug onto the 

  connector body and tighten very gently with a spanner (11mm).  

  Do not leave the connection finger tight. If you have bought a  

  weatherproof boot, slide the sleeve as far as it will go over the  

  connector body, so that it butts up against the booster housing.  

  Alternatively seal by binding the connector with amalgamating tape.

B. Preparing cable & fitting f connector

C.  Fixing aerial to a mast & routing cable

1x  Central boom: assembly square aluminium (L) approx 865mm  

  with 7x curved aluminium elements 145mm 

2x  Reflector booms: Square aluminium (L) approx 160mm with  

  3x reflector elements each: curved aluminium (L) approx 425mm

1x Digital balun with f connection and loop shaped dipole

1x Aerial clamp

Box  contents

Mast Clamp

For best results the aerial should be mounted on an outdoor aerial mast 

and pointed in the direction of the nearest transmitter* making sure it 

is in a position where the transmitter signal will not be obstructed by 

nearby trees and buildings.  If you are in any doubt about the direction 

in which the aerial should be pointing or the orientation of the aerial 

(horizontal for main transmitter, vertical for relay transmitter) check your 

neighbours’ aerials. 

If mounting on an existing mast check that the mast is in good condition 

and firmly fixed.

1.  Using the clamp supplied fix the aerial to the mast - see Fig. 5 & 6. 

2.  After the aerial direction has been fine tuned for best reception  

 

tighten nuts firmly until the aerial is securely fixed to the mast.

The aerial can also be loft mounted if a suitable loft mount is 
purchased. However this can reduce the strength of the signal received 
and outdoor installation is recommended.

For optimum performance it is very important that the coaxial cable  

should be routed as shown in Fig. 6.

PVC insulation tape can be used as shown to hold the cable in place.

CAUTION: When mounting the assembled aerial, always observe safety 

precautions and use the correct equipment. Unless you are competent in 

the use of ladders and other access equipment, do not work outdoors at 

roof height.  If in any doubt, refer to a qualified aerial installer.

Fig. 5

No picture:

 Check all connections from aerial to TV.

Poor picture:

 Check all connections from aerial to TV. 

Check aerial is properly aligned to the correct transmitter.
If the aerial has been loft mounted try mounting outside.
Make sure new digital coax cable has been used throughout  
the installation.
Check the transmitter signal is not obstructed by nearby trees  
or buildings.
If in a weak signal area or for long cable runs, installing a  
masthead amplifier will improve the signal.

Troubleshooting

Useful Websites for Digital Advice:

*To confirm that your home is in a coverage area, to find 

out what DTT channels should be available locally visit: 

www.dtg.org.uk/industry/coverage.html

and enter your postcode.

To find out your nearest transmitter’s distance and compass  

bearing select Trade view from the top bar.

fold braid back

over sheath

8mm

inner

wire

cut or tear 

away foil 

6.5mm

Fig. 3

screw connector

body onto cable

2mm approx.

end of  

insulation

should be  

flush with 

this face

Fig. 4

mast  

clamp

aerial 

boom

PVC

insulation

tape

Fig. 6

For further information, please contact: 

Customer Careline: 0901 293 0038

 

Calls are charged at £1 per minute from a BT landline

Call charges from other networks may vary

www.labgear.co.uk

© Philex Electronic Ltd.  MK42 0NX. 2010. V2 DI  

PLEASE NOTE: A coax plug is not included with this aerial. 
If you need to fit one to connect to a TV please follow the 
wiring guide shown below. Lengths shown below may vary 
with coax plug type.

1

2

3

4

5

Coax plug wiring instructions

1  Unscrew coaxial plug housing and slide cap 
  over cable.
2  Strip 23mm of cable outer sheath.  
  Gather copper braid, wrap around outer 
  sheath, slide claw over braid and crimp.
3  Strip 18mm of inner insulation to leave 5mm 
  exposed
4  Undo screw on plug/clamp, slide clamp over 
  inner wire & tighten screw. Reassemble plug

5  Trim inner wire flush with plug.

F connector