LM1012TTS Table-Top Label Applicator System
USER'S MANUAL
Made in the U.S.A.
© 2022 LABELMILL
01/01/2022 Model LM1012TTS
Page 52
TROUBLESHOOTING GUIDE
If the system malfunctions, it is necessary to determine where the problem exists in a normal sequence of operation.
The procedure of the unit is outlined in the left hand column of the table below to provide a systematic approach to
troubleshooting.
Problem
Possible Cause
Corrective Action
1.
Unit will not turn on.
A. Blown Main Fuse
Check main power fuse and replace if
necessary as shown on page 55.
2.
Take-up unit does not turn.
A. Friction plate failure in clutch.
B. Mechanical failure in clutch.
Consult Factory.
3.
Waste web tension too loose.
A. Clutch tension too low.
Adjust clutch as shown on page 15.
4.
Waste web breaks.
A. Clutch adjusted too tight.
B. Machine webbed incorrectly
C. Low quality webbing.
D. Friction plate failure in clutch.
E. Mechanical failure in clutch.
Adjust clutch as shown on page 15.
Re-web system as shown on page 10.
Consult label manufacturer.
Consult factory.
Consult factory.
5.
Label double feeds.
A. Label sensor out of adjustment.
B. Label Stop Position Incorrect
Adjust setting as shown on page 11.
Reduce Label Stop Position Setting.
6.
Tamp cylinder not up
A. A. No air
B. B. Hoses not connected correctly
Connect air and/or adjust regulator
Match tubes w/ numbers on manifold.
7.
Applicator module does not
function
A. Incorrect Cycle Type
C. B. No air
C. Hoses not connected correctly
Set correct Cycle Type in control.
Connect air and/or adjust regulator.
Match tubes w/ numbers on manifold.
8.
Power ON tamp/flag system
unit will not cycle
A. Cylinder not up.
B. Reed Switch out of adjustment
C. Incorrect Cycle Type
Refer to #6.
Adjust Switch up or down.
Set correct Cycle Type in control.